Softness tester TP-H10 is adopted with microprocessor controlled technology and liquid crystal display to view and observe test parameters and result values. It can calculate and print test data. Its compact and sleek design, easy operations makes it user friendly. It is used to measure softness of paper, tissue paper, sheets, fabric etc.
Request QuoteMeasuring range | 10 to 1000 mN |
Division value | 1 mN |
Accuracy | ± 1% |
Indicating Error | ≤ 0.5 |
Pressing depth of the measuring head | 8 + 0.5 mm |
Parallelism error between two brims of the specimen stages | ≤ 0.05 mm |
Slit width of the specimen stage | 5 mm, 6.35 mm, 10 mm, 20 mm |
Dimension | 570×410×200 mm |
Weight | 33 kg |
Power supply | AC220 V ± 10 % , 50 Hz |
Softness tester can measure softness of materials such as toilet paper of all grades, tobacco sheet, fiber fabric and so on.
Available Range :
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : 38×70 mm Sample (size) length : 90 to 200 mm Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable) Sample (size) length : 0 to 200 mm adjustableRelated Models :
Model | Sample size (L*B) | Rub pressure | Friction speed | Friction area (L*B) | No. of friction | Measuring range | Division value | Accuracy | Gauge | Contact pressure (to create false weight) | Contact diameter | Error of depth parallelism | Testing speed | Test range | Indicating Error | Indication variability | Pressing depth of the measuring head | Parallelism error between two brims of the specimen stages | Slit width of the specimen stage | Testing length | Sample size | Bend angle | Sample width | Sample maximum length | Parallelism | Dimension | Weight | Power supply |
TP-A10 | - | - | - | - | - | - | - | Chromaticity co-ordinate 0.0001 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-A11 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-B10 | - | - | - | - | - | (1-500) mN.m (divided into 7 small ranges) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-B11 | - | - | - | - | - | 0 to 30, 0 to 100 N,0 to 300 N | - | ± 1 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 15 mm, 25 mm, 50mm | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-B12 | - | - | - | - | - | 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N | - | ± 1 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 15 mm | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-B20 | - | - | - | - | - | 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N | - | ± 1 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 15 mm | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-C10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 450×250×1100 mm | - | - |
TP-C20 | - | - | - | - | - | - | 1 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 420×250×380 mm | - | - |
TP-C21 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 270×400×300 mm | - | - |
TP-C30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 240×288×435 mm | - | - |
TP-D10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-E10 | - | - | - | - | - | - | - | - | - | - | - | - | 200° ± 20° / min | 1 to 10000 mN | ± 1 % | - | - | - | - | 5, 10, 15, 20, 25, 50 mm | Width 38 ± 0.2 mm, length 70 mm | 1 to 90° | - | - | - | 200×230×350 mm | 15 kg | AC220 V ± 10 % , 50 Hz |
TP-E20 | - | - | - | - | - | 0 to 4 mm | - | 0.01 or 0.001 mm | Analogue gauge display | 100 ± 10 kPa | 16.0 ± 0.5 mm | 0.005 mm or 1 % | - | - | ± 0.0025 mm or ± 0.5 % | ≤ 0.0025 mm or ≤ 0.5 % | - | - | - | - | - | - | - | - | - | 233×160×120 mm | 5.5 kg | - |
TP-E21 | - | - | - | - | - | 0 to 20 mm | - | 0.01 mm | Analogue gauge display | 20 ± 0.5 kPa | 35.7 ± 0.5 mm | 0.03 mm | - | - | ± 0.0025 mm or ± 0.5 % | ≤ 0.0025 mm or ≤ 0.5 % | - | - | - | - | - | - | - | - | - | 233×160×120 mm | 5.5 kg | - |
TP-F10 | 230×50 mm (can join short samples together) | 20 ± 0.2 N | 43 times / min | 155×50 mm | 0 to 999, auto shutdown | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 275×302×297 mm | 25 kg | AC220 V ± 10 % , 50 Hz |
TP-G10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 15 mm | 300 mm | ≤ 0.1 mm | 240×520×70 mm | 4 kg | - |
TP-H10 | - | - | - | - | - | 10 to 1000 mN | 1 mN | ± 1% | - | - | - | - | - | - | ≤ 0.5 | - | 8 + 0.5 mm | ≤ 0.05 mm | 5 mm, 6.35 mm, 10 mm, 20 mm | - | - | - | - | - | - | 570×410×200 mm | 33 kg | AC220 V ± 10 % , 50 Hz |
TP-I10 | - | - | - | - | - | 0.1 to 10 kN | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-I11 | - | - | - | - | - | 1 to 50 kN | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-J10 | - | - | - | - | - | 0 to 1000 ml/min | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 410×300×1160 mm | About 15kg | - |
TP-J12 | - | - | - | - | - |
A (1 to 6) J indicating error ± 0.05 J B (1 to 12) J indicating error ± 0.05 J C (1 to 24) J indicating error ± 0.05 J D (1 to 48) J indicating error ± 0.05 J The indicating errors w.r.t measurement range of 20 to 80 % |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 800×470×840 mm | 185 kg | AC220 V ± 10 % , 50 Hz |
TP-J20 | - | - | - | - | - | 0 to 1000 mN | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-J21 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 kg | - |
TP-K10 | - | - | - | - | - | - | - | ± 0.5 % F.S. | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-K11 | - | - | - | - | - | - | - | ≤± 0.5 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-L10 | - | - | - | - | - | - | - | ± 1 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-L20 | - | - | - | - | - | - | - | ±0.1 s within 300 s | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-M10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-E30 | - | - | - | - | - | 0 to 5 mm | 0.001 mm | - | - | - | - | - | - | - | - | ≤ 0.0025 mm or ≤ 0.5 % | - | - | - | - | - | - | - | - | - | - | 25 Kg | - |
TP-J11 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 65 Kg | - |