Puncture strength tester TP-J12 has electrical mechanical integration design, with compact structure, easy maintenance. The puncture tester has an open design, simple operation, automatic measurement with high accuracy and stable performance gives reliable results. It is designed in a way to avoid any vibration that would affect the test values.
Request QuoteMeasuring range |
A (1 to 6) J indicating error ± 0.05 J B (1 to 12) J indicating error ± 0.05 J C (1 to 24) J indicating error ± 0.05 J D (1 to 48) J indicating error ± 0.05 J The indicating errors w.r.t measurement range of 20 to 80 % |
Frictional resistance | <0.25 J |
Pyramid dimension | Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm |
Dimension | 800×470×840 mm |
Weight | 185 kg |
Power supply | AC220 V ± 10 % , 50 Hz |
Puncture strength tester is an essential instrument used in paper and cardboard box manufacturing plants, industry.
Available Range :
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : 38×70 mm Sample (size) length : 90 to 200 mm Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable) Sample (size) length : 0 to 200 mm adjustableRelated Models :
Model | Measuring range | Capacity | Resolution | Indication error | Tearing arm | Tearing angle | Chips distance | Clamp- paper | Resection length | Tearing distance | Frictional resistance | Pyramid dimension | Platen Size | Operating stroke | Compression speed | Impact angle | Unit | Error | Sample amount | Speed adjustment range | Track & force speed in stacking test | Test area | Area differential pressure | Inner diameter of grip ring | Dimension | Weight | Power supply |
TP-A10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-A11 | - | - | - | ≤ 0.5 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-B10 | (1-500) mN.m (divided into 7 small ranges) | - | - | 0.02 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-B11 | 0 to 30, 0 to 100 N,0 to 300 N | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-B12 | 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-B20 | 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220 V ± 10 %, 50 Hz |
TP-C10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 450×250×1100 mm | - | - |
TP-C20 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 420×250×380 mm | - | - |
TP-C21 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 270×400×300 mm | - | - |
TP-C30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 240×288×435 mm | - | - |
TP-D10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-E10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 200×230×350 mm | 15 kg | AC220 V ± 10 % , 50 Hz |
TP-E20 | 0 to 4 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 233×160×120 mm | 5.5 kg | - |
TP-E21 | 0 to 20 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 233×160×120 mm | 5.5 kg | - |
TP-F10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 275×302×297 mm | 25 kg | AC220 V ± 10 % , 50 Hz |
TP-G10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 240×520×70 mm | 4 kg | - |
TP-H10 | 10 to 1000 mN | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 570×410×200 mm | 33 kg | AC220 V ± 10 % , 50 Hz |
TP-I10 | 0.1 to 10 kN | - | - | < ± 1% | - | - | - | - | - | - | - | - | 500×500 mm (customized) | 500 mm (customized) | 10 mm/ min | - | - | - | - | 2 to 100 mm/ min | 2 mm/ min | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-I11 | 1 to 50 kN | - | - | < ± 1% | - | - | - | - | - | - | - | - | 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized) | 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized) | 10 mm/ min | - | - | - | - | 2 to 100 mm/ min | 2 mm/ min | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-J10 | 0 to 1000 ml/min | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 10 ± 0.02 cm2 | 1 ± 0.01 kPa | 35.68 ± 0.05 mm | 410×300×1160 mm | About 15kg | - |
TP-J12 |
A (1 to 6) J indicating error ± 0.05 J B (1 to 12) J indicating error ± 0.05 J C (1 to 24) J indicating error ± 0.05 J D (1 to 48) J indicating error ± 0.05 J The indicating errors w.r.t measurement range of 20 to 80 % |
- | - | - | - | - | - | - | - | - | <0.25 J | Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm | - | - | - | - | - | - | - | - | - | - | - | - | 800×470×840 mm | 185 kg | AC220 V ± 10 % , 50 Hz |
TP-J20 | 0 to 1000 mN | - | 0.1 mN | ± 1 % | 104 ± 1 mm | 27.5° ± 0.5° | - | - | - | 43 ± 0.5 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-J21 | - | 10 -16000 mN | 0.1 mN | - | 104 ± 1 mm | 27.5° ± 5° | 180 mm | 2.8 ± 0.3 mm | 20 ± 0.5 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 kg | - |
TP-K10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 170 ± 15 ml/min | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-K11 | - | - | 0.01 kPa | - | - | - | - | - | - | - | - | - | - | - | 95 ± 5 ml/min | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-L10 | - | - | 1 N | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-L20 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-M10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-E30 | 0 to 5 mm | - | - | ± 0.0025 mm or ± 0.5 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 25 Kg | - |
TP-J11 | - | - | 0.001lbf/in² | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 65 Kg | - |