Mullen burst tester TP-K11 is used to measure the bursting strength of paper submitted to increasing hydraulic pressure. Used in testing bursting strength of all types of papers in the 0 to 1600 kPa range depending on clamp pressure. It has mechanically & electrically integrated modern design, with compact structure & easy for maintenance. The advantage of user-friendly operations, stable performance makes this tester an essential instrument for papermaking, packing, inspection and research.
Request QuoteMeasurement range | 50 to 1600 kPa-paper and 50 to 5600 kPa-paper |
Resolution | 0.01 kPa |
Accuracy | ≤± 0.5 % |
Compression speed | 95 ± 5 ml/min |
Clamp pressure | 400 kPa to 1200 kPa(adjustable) |
Diameter of upper clamp | 30.5 ± 0.1 mm |
Diameter of lower clamp | 33.1 ± 0.1 mm |
Pneumatic pressure | 0.3 to 0.5 MPa |
Film resistance | (9±0.2)mm/(30±5)kPa |
Dimension (L×W×H) | 428×318×412 mm |
Net weight | 50 kg |
Power supply | AC220 V ± 10 % , 50 Hz |
Mullen burst tester is used to measure bursting strength of paperboard, paper across paper industry, packaging industry, printing industry.
Available Range :
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : 38×70 mm Sample (size) length : 90 to 200 mm Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable) Sample (size) length : 0 to 200 mm adjustableRelated Models :
Model | Measurement range | Measuring scope | Folding angle | Tensile scope | Folding head suture size | Folding radius | Resolution | Accuracy | Variability | Speed | Vacuum system volume (ml) | Contact pressure | Vacuum scope | Air volume (50.66 kPa down to 48.00 kPa) | Maximum distance | Compression speed | Clamp pressure | Diameter of upper clamp | Diameter of lower clamp | Pneumatic pressure | Film resistance | Dimension (L×W×H) | Net weight | Power supply |
TP-A10 | - | - | - | - | - | - | - | Chromaticity co-ordinate 0.0001 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 23 kg | 220 V ± 10 %, 50 Hz |
TP-A11 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 kg | 220 V ± 10 %, 50 Hz |
TP-B10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 15 kg | 220 V ± 10 %, 50 Hz |
TP-B11 | - | - | - | - | - | - | - | ± 1 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 65 kg | 220 V ± 10 %, 50 Hz |
TP-B12 | - | - | - | - | - | - | - | ± 1 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 40 kg | 220 V ± 10 %, 50 Hz |
TP-B20 | - | - | - | - | - | - | - | ± 1 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 55 kg | 220 V ± 10 %, 50 Hz |
TP-C10 | 0 to 100° SR | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-C20 | 0 to 200 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-C21 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-C30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-D10 | 0.01 to 10 N | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-E10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-E20 | - | - | - | - | - | - | - | 0.01 or 0.001 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-E21 | - | - | - | - | - | - | - | 0.01 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-F10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-G10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-H10 | - | - | - | - | - | - | - | ± 1% | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-I10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 10 mm/ min | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-I11 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 10 mm/ min | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-J10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-J12 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-J20 | - | - | - | - | - | - | 0.1 mN | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-J21 | - | - | - | - | - | - | 0.1 mN | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-K10 | 0 to 5600 kPa | - | - | - | - | - | - | ± 0.5 % F.S. | - | - | - | - | - | - | - | 170 ± 15 ml/min | ≥ 690 kPa | 31.5 ± 0.05 mm | 31.5 ± 0.05 mm | 0.45 to 0.6 MPa |
For bulge height = 10 mm, The pressure = 170 to 220 kPa For bulge height = 18 mm, The pressure = 250 to 350 kPa |
480×420×600 mm | 65 kg | AC220 V ± 10 % , 50 Hz |
TP-K11 | 50 to 1600 kPa-paper and 50 to 5600 kPa-paper | - | - | - | - | - | 0.01 kPa | ≤± 0.5 % | - | - | - | - | - | - | - | 95 ± 5 ml/min | 400 kPa to 1200 kPa(adjustable) | 30.5 ± 0.1 mm | 33.1 ± 0.1 mm | 0.3 to 0.5 MPa | (9±0.2)mm/(30±5)kPa | 428×318×412 mm | 50 kg | AC220 V ± 10 % , 50 Hz |
TP-L10 | 5 to 500 N, 50 to 3000 N | - | - | - | - | - | 1 N | ± 1 % | ≤ 1 % | 12.5 ± 2.5 mm/min | - | - | - | - | 78 mm | - | - | - | - | - | - | 450×400×500 mm | 75 kg | AC220 V ± 10 % , 50 Hz |
TP-L20 | - | ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s) | - | - | - | - | - | ±0.1 s within 300 s | - | - |
Bigger volume: 380 ± 1 Smaller volume: 38 ± 1 |
100 ± 2 kPa |
I) 50.66 to 48.00 II) 50.66 to 48.00 III) 50.66 to 29.33 Automatic: No limit |
Big vacuum volume: 10.00 ± 0.20 ml Small vacuum volume: 1.00 ± 0.05 ml |
- | - | - | - | - | - | - | 325×390×430 mm | 30 kg | AC220 V ± 10 % , 50 Hz |
TP-M10 | - | 0 to 99999 s | 135° ± 2° | 4.9 to 14.7 N | 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm | 0.38 ± 0.02 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 320×320×450 mm | 35 kg | AC220 V ± 10 % , 50 Hz |
TP-E30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-J11 | - | - | - | - | - | - | 0.001lbf/in² | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |