Table Top Autoclave LTTA-L11 is a compact laboratory steam sterilizer used to sterilize instruments, glassware, and culture media using saturated steam at 121°C and 134°C. It is designed for routine sterilization where controlled temperature, pressure, and repeatable cycles are required.
Table Top Autoclave LTTA-L11 is used to perform moist heat sterilization of reusable laboratory items including instruments, glassware, and culture media. It helps maintain contamination control and supports routine sterilization practices aligned with laboratory protocols.
Best for
• Small to medium laboratories
• Routine sterilization workflows
• Bench-top installation
• Instruments, glassware, and media
Not suitable for
• High-volume bulk sterilization
• Large centralized sterilization facilities
• Continuous industrial-scale operations
• Water is heated to generate saturated steam
• Steam fills the sealed chamber
• Temperature and pressure reach sterilization levels
• Steam penetrates materials and inactivates microorganisms
• Controlled exhaust and cooling complete the cycle
• Steam sterilization using controlled temperature and pressure
• Programmable sterilization cycles
• Stainless steel chamber for repeated use
• Digital control panel for monitoring
• Safety interlock system
• Compact tabletop installation
Q1. What items can be sterilized using this autoclave?
Glassware, instruments, culture media, and heat-resistant consumables can be sterilized using steam under pressure
Q2. What sterilization temperatures are available?
Standard sterilization cycles operate at 121°C and 134°C
Q3. Is this autoclave suitable for routine laboratory use?
Yes, it is designed for repeated sterilization cycles in laboratory environments
Q4. How are sterilization cycles monitored?
Temperature, pressure, and time are displayed on a digital control panel for real-time monitoring
Q5. Can it be placed on a laboratory bench?
Yes, the compact design allows tabletop installation
Q6. What type of sterilization method does LTTA-L11 use?
It uses moist heat sterilization through saturated steam under controlled conditions
Q7. Is the autoclave suitable for wrapped instruments?
Yes, it supports both wrapped and unwrapped instruments
Q8. Can liquid media be sterilized in this unit?
Yes, it allows safe sterilization of compatible liquid media
Q9. Does the autoclave include safety protection features?
Yes, it includes a door interlock system for safe operation
Q10. How is sterilization cycle completion indicated?
Cycle completion is shown on the digital display panel
This autoclave is used in laboratory environments following standard sterilization practices where controlled steam sterilization is required for contamination prevention and process consistency.
• Sterilization of laboratory instruments
• Preparation of culture media
• Clinical laboratory sterilization workflows
• Biotechnology laboratory operations
• For higher capacity sterilization refer to Vertical Autoclaves
• For similar models refer to Table Top Autoclave LTTA-L10
• For process understanding refer to Steam Sterilization Guide
Table Top Autoclave LTTA-L11 is an 11 L steam sterilizer operating at 121°C and 134°C for routine laboratory and clinical sterilization. It offers programmable cycles, digital control, and safety interlock for consistent sterilization of instruments, media, and glassware.
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608