Vertical Autoclave LVA-A14 is a laboratory steam sterilization system used to sterilize culture media, instruments, glassware, and waste using saturated steam at temperatures up to 134 °C. It is designed for small to medium capacity sterilization where controlled temperature, pressure, and cycle duration are required.
Vertical Autoclave LVA-A14 is used to sterilize laboratory materials by exposing them to high-pressure saturated steam. It helps eliminate microorganisms and supports contamination control in laboratory and healthcare environments.
Best for
• Small to mid-volume sterilization
• Laboratory and clinical environments
• Routine sterilization of media and instruments
• Facilities handling laboratory waste
Not suitable for
• High-volume industrial sterilization
• Large centralized sterilization systems
• Fully automated high-throughput operations
• Water is heated to generate saturated steam
• Steam fills the sealed vertical chamber
• Temperature and pressure reach sterilization levels
• Steam penetrates materials and destroys microorganisms
• Pressure is released safely before unloading
• Vertical chamber for space-efficient installation
• Steam sterilization using controlled parameters
• Programmable sterilization cycles
• Microprocessor-based control system
• Stainless steel chamber for durability
• Safety interlock mechanism for safe operation
• Required sterilization capacity
• Type of materials such as media, instruments, or waste
• Available laboratory space
• Required temperature and cycle control
• Laboratory or clinical workflow requirements
• Table Top Autoclaves for compact bench-top use
• Horizontal Autoclaves for high-capacity sterilization
• Steam Sterilizers for dedicated applications
Q1. What materials can be sterilized using this autoclave?
Culture media, glassware, instruments, dressings, and laboratory waste can be sterilized
Q2. Is this autoclave suitable for laboratory waste sterilization?
Yes, it is suitable for decontaminating laboratory waste
Q3. What temperature is used during sterilization?
Sterilization cycles operate up to 134 °C
Q4. Does the unit include safety protection?
Yes, it includes pressure control and safety interlock systems
Q5. Is this autoclave suitable for pharmaceutical labs?
Yes, it is used in pharmaceutical and clinical laboratories
Q6. Can liquid media be sterilized using this autoclave?
Yes, it supports sterilization of liquid culture media
Q7. Does it support gravity displacement cycles?
Yes, it operates using gravity displacement sterilization
Q8. Is the chamber suitable for repeated high-temperature exposure?
Yes, the stainless steel chamber is designed for repeated use
Q9. Can glassware be sterilized safely?
Yes, laboratory-grade glassware can be sterilized under proper conditions
Q10. Is manual water filling required?
Yes, manual water filling is typically required
This autoclave is used in laboratory environments aligned with GLP and GMP practices where controlled steam sterilization is required for contamination control and process consistency.
• Sterilization of microbiological culture media
• Decontamination of laboratory instruments
• Processing of laboratory waste
• Routine sterilization in research laboratories
• For compact systems refer to Table Top Autoclaves
• For high-capacity systems refer to Horizontal Autoclaves
• For selection guidance refer to Autoclave Buying Guide
Vertical Autoclave LVA-A14 is a 14 L steam sterilization system operating up to 134 °C and 0.22 MPa. With microprocessor control and programmable cycles, it provides compact and accurate sterilization of laboratory media, instruments, and waste.