A vertical autoclave is a steam sterilization system that uses pressurized saturated steam to eliminate microorganisms and spores from laboratory materials. It is used for sterilizing culture media, instruments, glassware, dressings, and biohazardous waste.
Labtron LVA-P10 Vertical Autoclave is used for high-temperature steam sterilization of reusable laboratory materials. It is applied for culture media preparation, glassware decontamination, surgical instrument processing, and microbiological waste treatment.
Materials are loaded into the vertical chamber.
The chamber is sealed before cycle starts.
Saturated steam is generated inside the chamber.
Air is displaced for uniform steam penetration.
Temperature and pressure reach selected sterilization levels.
Holding time is maintained for microbial inactivation.
Pressure is released safely after cycle completion.
Sterilized materials are removed after cooling.
Vertical top-loading chamber for laboratory containers
Steam sterilization using controlled temperature and pressure
Digital control panel for cycle monitoring and parameter setting
Over-temperature and over-pressure safety protection
Stainless steel chamber for repeated laboratory sterilization cycles
Manual or automatic water filling options depending on configuration
Choose LVA-P10 when medium-volume laboratory sterilization is required for culture media, instruments, glassware, dressings, and microbiological waste. It is suitable when vertical loading, programmable timing, and steam sterilization at 121 °C or 134 °C are required.
100 L chamber capacity is suitable
Medium-volume laboratory sterilization is required
121 °C and 134 °C cycles are needed
Digital cycle control is preferred
Vertical top-loading fits the available space
Small tabletop sterilization is preferred
High-throughput continuous sterilization is required
Pass-through cleanroom sterilization is required
Pharmaceutical manufacturing laboratories
Biotechnology and life science research labs
Hospital CSSD and clinical laboratories
Academic and teaching laboratories
Environmental and microbiology testing facilities
Q1. What items can be sterilized using this autoclave?
Glassware, culture media, laboratory instruments, dressings, and microbiological waste.
Q2. What sterilization temperatures are supported?
Standard laboratory cycles at 121 °C and 134 °C.
Q3. Is this unit suitable for pharmaceutical labs?
Yes, it is commonly used in pharmaceutical and regulated laboratory environments.
Q4. How is cycle time controlled?
Cycle duration is set through the digital control interface.
Q5. Does it include safety protection?
Yes, the system includes pressure and temperature safety controls.
Sterilization of culture media in microbiology labs
Decontamination of laboratory glassware
Processing of surgical instruments in clinical labs
Treatment of biohazardous laboratory waste
Vertical Autoclave LVA-P10 is used in sterilization programs aligned with Good Manufacturing Practice guidelines, laboratory biosafety protocols, and standard steam sterilization practices.
Vertical Autoclave LVA-P10 is a 100 L vertical steam sterilizer for instruments, glassware, culture media, dressings, and biohazardous waste. It operates at 121 °C or 134 °C under 0.22 MPa with a 0–99 minute timer, digital control interface, stainless steel chamber, and safety protection for repeatable laboratory sterilization workflows.