What is Vertical Autoclave LVA-C13
Vertical Autoclave LVA-C13 is a digital top-loading steam sterilizer designed for sterilizing laboratory media, instruments, glassware, and biological waste using saturated steam up to 134 °C.
Product Snapshot
Attribute | Details |
Product Name | Vertical Autoclave |
Model Number | LVA-C13 |
Product Type | Laboratory Steam Sterilization Equipment |
Used For | Sterilization of media, instruments, glassware, and laboratory waste |
Industries | Pharmaceutical, Biotechnology, Healthcare, Research Laboratories, Food Testing |
Alternative Equipment | Horizontal Autoclave, Benchtop Autoclave, Portable Steam Sterilizer |
Warranty | 1 Year Standard Warranty |
Support | Technical documentation and application guidance available |
What Is This Product Used For
Vertical Autoclave LVA-C13 is used for sterilizing laboratory materials through high-pressure saturated steam exposure. It eliminates microorganisms from reusable instruments, microbiological media, glassware, and biological waste before disposal or reuse.
Industries That Use This Product
• Pharmaceutical manufacturing laboratories
• Biotechnology and microbiology research facilities
• Hospitals and clinical sterilization departments
• Academic and research institutes
• Food and environmental testing laboratories
How Does Vertical Autoclave LVA-C13 Work
Vertical Autoclave generates saturated steam inside a sealed chamber. Temperature and pressure rise to sterilization levels, allowing steam to penetrate loads and inactivate microorganisms. After the holding phase, controlled exhaust and cooling prepare materials for safe removal.
Core Functional Capabilities
• Steam sterilization with controlled temperature and pressure
• Digital monitoring of sterilization parameters
• Programmable cycle timing
• Pressure and temperature safety regulation
• Suitable for routine laboratory sterilization
• Applicable for microbiology, research, and clinical workflows
Technical Specifications
Parameter | Specification |
Sterilization Temperature | Up to 134 °C |
Working Pressure | Approx. 0.22 MPa |
Timer Range | Programmable cycle timing |
Heating Method | Electric steam generation |
Control System | Digital control interface |
Power Supply | 220 V AC, 50 Hz |
Best Fit vs Limitations
Best Fit | Limitations |
Microbiology and research laboratories | Chamber volume not specified |
Pharmaceutical QC workflows | Not ideal when exact capacity matching is required |
Clinical sterilization rooms | Requires proper cycle selection by load type |
Waste and media sterilization | Not suitable for very high-throughput central sterilization |
How to Choose This Vertical Autoclave
• Routine sterilization of glassware and media is required
• Programmable steam sterilization cycles are preferred
• Controlled temperature and pressure processing is needed
• Infectious waste sterilization is part of the workflow
• Research, clinical, or pharmaceutical sterilization programs are followed
Alternative Equipment
• Horizontal autoclaves for higher capacity sterilization
• Benchtop autoclaves for compact laboratory environments
• Portable steam sterilizers for field or small laboratory use
Frequently Asked Questions About Vertical Autoclave LVA-C13
Q1. What materials can be sterilized using this autoclave?
It sterilizes laboratory glassware, culture media, surgical instruments, textile materials, and microbiological waste.
Q2. What sterilization temperature is commonly used?
Typical cycles operate at 121 °C or 134 °C depending on load type and application.
Q3. Is this autoclave suitable for microbiology laboratories
Yes, it is suitable for sterilizing culture media, Petri dishes, glassware, and laboratory instruments.
Q4. How long does a sterilization cycle take?
Cycle time depends on load volume and selected parameters, typically ranging from 20 to 60 minutes.
Q5. Can biological waste be processed in this autoclave?
Yes, it can sterilize infectious and bio hazardous laboratory waste before disposal.
Typical Application Scenarios
• Sterilization of microbiological culture media
• Processing reusable surgical instruments
• Decontamination of laboratory glassware
• Sterilization of biological waste
Compliance and Standards
• Good Laboratory Practice
• Good Manufacturing Practice sterilization workflows
• Microbiological laboratory sterilization protocols
Internal Linking Opportunities
Section | Suggested Links |
Parent Category | Vertical Autoclaves |
Related Products | Horizontal Autoclaves, Benchtop Autoclaves |
Buying Guides | Guide to Steam Sterilization in Laboratories |
Technical Articles | Understanding Autoclave Sterilization Cycles |
Comparison Table of Vertical Autoclave LVA-C13
Feature | LVA-B12 | LVA-B13 | LVA-B14 | LVA-B15 | LVA-C10 | LVA-C11 | LVA-C12 | LVA-C13 |
Capacity | 12 L | ~50 L | 14 L | 15 L | 100 L | 50 L | 12 L | Not specified |
Loading | Vertical | Vertical | Vertical | Vertical | Vertical | Vertical | Vertical | Vertical |
Temperature | Up to 134 °C | Up to 134 °C | Up to 134 °C | Up to 134 °C | 121/134 °C | 121/134 °C | Up to 134 °C | Up to 134 °C |
Pressure | Up to 0.22 MPa | ~0.22 MPa | 0.22 MPa | 0.22 MPa | 0.12–0.22 MPa | 0.12–0.22 MPa | Up to 0.22 MPa | Approx. 0.22 MPa |
Control | Microprocessor | Digital | Preset | Microprocessor | Manual/Semi-auto | Microprocessor | Adjustable/Preset | Digital |
Use Case | Small labs | Medium labs | Teaching labs | Routine labs | High-volume labs | Medium labs | Small labs | Research and microbiology labs |
Executive Summary
Vertical Autoclave LVA-C13 is a digital top-loading steam sterilizer for laboratory, pharmaceutical, research, and healthcare applications. It operates up to 134 °C and approx. 0.22 MPa, with programmable timing for liquids, instruments, glassware, and biological waste. It is suitable for laboratories requiring controlled temperature, pressure, and timing for validated sterilization workflows.