Vertical Autoclave LVA-E10 - Certified Laboratory Vertical Sterilizer


What Is a Vertical Autoclave?

A vertical autoclave is a steam sterilization system that uses pressurized saturated steam to sterilize laboratory materials. It features a top-loading vertical chamber designed for space-efficient installation and routine sterilization of media, instruments, and laboratory waste.


Product Snapshot

Attribute

Details

Product Name

Vertical Autoclave

Model Number

LVA-E10

Product Type

Steam Sterilization Equipment

Used For

Sterilization of laboratory media, instruments, and waste

Industries

Pharmaceutical, Biotechnology, Clinical Diagnostics, Research Laboratories, Healthcare

Alternative Equipment

Horizontal Autoclave, Table Top Autoclave

Warranty

1 Year Standard Warranty

Support

Technical documentation and application guidance available


What Is This Product Used For?

Vertical Autoclave LVA-E10 is used for sterilizing microbiological media, glassware, metal instruments, and laboratory waste using saturated steam under pressure.

Key Uses

  • Culture media sterilization

  • Glassware and instrument processing

  • Biohazard waste treatment

  • Routine laboratory sterilization

  • Microbiology and research workflows


How Does Vertical Autoclave LVA-E10 Work?

Step-by-Step Process

  1. Load materials into the vertical chamber

  2. Secure the lid with safety locking

  3. Generate saturated steam inside the chamber

  4. Increase temperature and pressure to sterilization levels

  5. Maintain holding phase for microbial inactivation

  6. Monitor parameters via digital control system

  7. Perform controlled exhaust

  8. Remove sterilized materials after cooling


Core Functional Capabilities

  • Vertical chamber design for space-efficient installation

  • Steam sterilization for media, instruments, and waste

  • Microprocessor-controlled temperature and cycle settings

  • Pressure and temperature monitoring via digital display

  • Safety interlock system for secure operation

  • Stainless steel chamber for laboratory use


Technical Specifications

Parameter

Specification

Chamber Capacity

100 Liters

Sterilization Temperature

Up to 134 °C

Working Pressure

0.22 MPa

Control System

Microprocessor-based control

Chamber Material

Stainless Steel

Heating Method

Electric heating

Power Supply

220 V AC, 50 Hz

Installation Type

Floor-standing vertical unit


How to Choose This Vertical Autoclave

Choose This Model If:

  • Medium-volume sterilization is required

  • Laboratory space is limited

  • Routine sterilization of media and instruments is needed

  • Programmable cycles are required

  • GMP or institutional sterilization workflows are followed

Avoid This Model If:

  • High-capacity batch sterilization is required

  • Large or heavy loads are processed regularly

  • Horizontal loading is preferred

  • Industrial-scale sterilization is needed


Industries That Use This Product

This vertical autoclave is commonly applied in:

  • Pharmaceutical production and quality control laboratories

  • Biotechnology and life science research facilities

  • Clinical and diagnostic laboratories

  • Academic and institutional research centers

  • Hospital laboratory and central service departments

Its use spans both regulated and quality-managed laboratory environments.


Typical Application Scenarios

  • Sterilization of culture media in pharmaceutical laboratories

  • Decontamination of reusable laboratory instruments

  • Sterilization of microbiological waste

Routine lab sterilization in research and academic institutions


Frequently Asked Questions  About Vertical Autoclave LVA-E10

Q1. What materials can be sterilized?
       Culture media, laboratory glassware, metal instruments, and biological waste.

Q2. Is it suitable for microbiology laboratories?
       Yes, it is used for routine sterilization of media and instruments.

Q3. How is temperature controlled?
       Through a microprocessor-based control system.

Q4. Can it sterilize waste?
      Yes, it is used for biohazard and laboratory waste sterilization.

Q5. What safety features are included?
       Pressure relief valves, door interlocks, and automatic shutoff.


Comparison Table Of Vertical Autoclave LVA-E10 

Feature

LVA-B12

LVA-B13

LVA-B14

LVA-D10

LVA-D11

LVA-D12

LVA-D13

LVA-E10

Chamber Volume

12 L

~50 L

14 L

Medium (~unspecified)

50 L

75 L

Mid-capacity (~50–60 L)

100 L

Loading Type

Vertical / Top

Vertical / Top

Vertical / Top

Vertical / Top

Vertical / Top

Vertical / Top

Vertical / Top

Vertical / Top

Sterilization Temperature

Up to 134 °C

Up to 134 °C

Up to 134 °C

121–134 °C

134 °C

105–134 °C

Up to 134 °C

Up to 134 °C

Working Pressure

Up to 0.22 MPa

Approx. 0.22 MPa

0.22 MPa

0.1–0.22 MPa

0.22 MPa

0.22 MPa

0.22 MPa

0.22 MPa

Control System

Microprocessor digital

Programmable digital

Preset temperature & timer

Programmable digital interface

Digital touchscreen interface

Digital LCD with touch keypad

Digital control interface

Microprocessor-based

Cycle Options

Programmable / adjustable

Programmable cycles

Preset cycles

Programmable / customizable

Programmable, customizable

Programmable with auto discharge

Programmable & holding cycles

Programmable / adjustable

Materials Processed

Media, instruments, glassware, waste

Media, instruments, biohazard waste

Media, instruments, glassware, waste

Media, instruments, glassware, biohazard waste

Media, instruments, glassware, biological materials

Glassware, biological samples, culture media, instruments

Glassware, culture media, instruments, biohazard waste

Media, instruments, glassware, biohazard waste

Safety Features

Over-temp, pressure interlock

Safety interlocks, monitoring

Pressure interlock, over-temp protection

Over-pressure & temperature protection

Safety interlocks, auto-shutdown, optional drying

Safety interlocks, over-temp & over-pressure, auto shutdown

Over-pressure & over-temperature protection, door interlocks

Safety interlocks, pressure relief, door locks, auto shutoff

Optional Drying

No

No

No

No

Yes

Yes

No

No

Mobility

Fixed

Fixed

Fixed

Fixed

Fixed

Yes (castor wheels)

Fixed

Fixed

Typical Use

Small to medium lab sterilization

Lab, healthcare, research sterilization

Small batch sterilization

Routine lab sterilization, research

Laboratory, healthcare, research sterilization

Sterilization with mobility

Routine & mid-capacity lab sterilization

Medium-volume lab sterilization, research & clinical workflows

Industries

Pharmaceutical, Biotech, Healthcare, QC

Pharmaceutical, Clinical, Biotech, Healthcare, Research

Pharmaceutical, Biotech, Healthcare, Academic

Pharmaceutical, Biotech, Clinical, Research, Food Testing

Pharmaceutical, Biotech, Microbiology, Healthcare

Pharmaceutical, Biotech, Microbiology, Healthcare

Pharmaceutical, Biotech, Healthcare, Research, Food Testing

Pharmaceutical, Biotechnology, Clinical Diagnostics, Research Laboratories, Healthcare

Space Requirement

Compact / Bench-top

Medium

Compact

Moderate

Moderate

Compact + Mobile

Moderate / Mid-size

Floor-standing / Moderate


Executive Summary

Vertical Autoclave LVA-E10 is a 100 L floor-standing steam sterilizer designed for sterilizing culture media, instruments, glassware, and laboratory waste. It operates at up to 134 °C and 0.22 MPa using saturated steam, with microprocessor-controlled cycles, safety interlocks, and a vertical top-loading chamber for consistent sterilization in laboratory environments.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608