Our broad list of spectrophotometers includes Visible spectrophotometers, UV/Vis spectrophotometers and Double beam UV/Vis spectrophotometers with broad wavelength range covering 190mm to 1100mm.
Wavelength Range : 190 to 1100 nm
Spectral Bandwidth : 1.8 nm
Optical System : Double beam
Wavelength Accuracy : ±0.3 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 1.8 nm
Optical system : Double beam; 1200 lines/mm grating
Wavelength accuracy : ±0.1nm (D2 656.1nm), ±0.3nm @ all
Wavelength Range : 190 to 1100 nm
Spectral Bandwidth : 1.8 nm
Optical System : Double beam, C-T monochromator,1200 L/mm holographic grating
Wavelength Accuracy : ±0.3 nm
Wavelength Range : 190 to 1100 nm
Spectral Bandwidth : 1.0 nm
Optical System : Double beam
Wavelength Accuracy : ±0.3 nm
Optical System : Double beam
Wavelength Range : 190 to 1100 nm
Band Width : 1.8 nm
Wavelength Accuracy : ± 0.3 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 1.0 to 5.0 nm (adjustable)
Optical system : Double beam, C-T monochromator, 1600 L/mm holographic grating
Wavelength accuracy : ±0.3 nm
Wavelength Range : 190 to 900nm
Spectral Bandwidth : 4nm, 2nm, 1nm, 0.5nm, 0.2nm, 0.1nm
Optical System : Double beam
Wavelength Accuracy : ±0.1nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 0.5/1/2/4 nm
Wavelength Accuracy : ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range
Wavelength Repeatability : ≤ 0.1 nm
Wavelength Range : 190 to 1100nm
Wavelength Accuracy : ±0.3nm
Wavelength Repeatability : ≤ 0.1nm
Spectral Bandwidth : 2nm or 1nm
Wavelength range : 190 ~ 1100 nm
Spectral bandwidth : 2 nm
Wavelength accuracy : 0.5 nm
Wavelength repeatability : ≤ 0.2 nm
Wavelength Range : 190 ~ 1100 nm
Setting Wavelength : Automatic
Spectral Bandwidth : 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Wavelength Accuracy : ± 0.3 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 2 nm
Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability : ≤ 0.1 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 1 nm
Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability : ≤ 0.1 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 0.5/1/2/4/5 nm
Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability : ≤ 0.1 nm
Wavelength Range : 190 to 1100 nm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.2 nm
Spectral Bandwidth : 1.8/1.0 nm
Wavelength Range : 190nm to 1100nm
Wavelength Accuracy : ± 0.3nm
Wavelength Repeatability : ≤ 0.1nm
Spectral Bandwidth : 0.5 to 6.0nm
Wavelength range : 200 - 800 nm
Path length : 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy : ± 1 nm
Wavelength Resolution : ≤ 3 nm (FWHM at Hg 546 nm)
Wavelength range : 190 to 850 nm
Wavelength accuracy : ± 1 nm
Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
Cuvette details : Recyclable micro cuvette, 8.5 mm sample level height
Wavelength range : 200 - 850 nm
Path length : 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy : ± 1 nm
Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
Wavelength : 260 nm and 280 nm; Fixed
Spectral resolution : ≤ 8 nm
Path length : 0.5 mm
Minimum sample size : 1 to 2 µl
Wavelength range : 230 nm, 260 nm, 280 nm
Path length : 1.0 mm, 0.2 mm
Minimum Sample size : 0.3 - 2.0 µl
Absorbance range : 0.2 - 75A (10 mm equivalent absorbance)
Cuvette : No
PC : Inbuilt
Wavelength range : 190 - 850 nm
Path length : 1 mm, 0.2 mm ,0.04 mm
Cuvette : Yes
Wavelength Range : 190 - 850 nm
Light Path Length : 1 mm, 0.05 mm
Wavelength Accuracy : ± 1 nm
Cuvette : Yes
Temperature : Room Temperature 42 ºC
PC : Inbuilt
Wavelength range : 190 - 850 nm
Cuvette : Yes
Temperature : 4 ºC - 42 ºC (Heating & Cooling)
PC : Inbuilt
Wavelength range : 190 - 850 nm
Wavelength Range : 200 to 1000 nm
Spectral Bandwidth : 4.0 nm
Optical System : Single beam
Wavelength Accuracy : ±0.2 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 2 nm
Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability : ≤ 0.1 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 1 nm
Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability : ≤ 0.1 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 0.5/1/2/4/5 nm
Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability : ≤ 0.1 nm
Wavelength Range : 190 ~ 1100 nm
Spectral Bandwidth : 1 nm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : 0.2 nm
Wavelength Range : 190 ~ 1100 nm
Spectral Bandwidth : 1.8 nm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : 0.2 nm
Wavelength Range : 190 ~ 1100 nm
Setting Wavelength : Automatic
Spectral Bandwidth : 2 nm
Wavelength Accuracy : ± 0.5 nm
Wavelength Range : 190 ~ 1100 nm
Setting Wavelength : Automatic
Spectral Bandwidth : 1.8 nm
Wavelength Accuracy : ± 0.3 nm
Wavelength Range : 190 ~ 1100 nm
Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm adjustable
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm
Wavelength Range : 190 ~ 1100 nm
Setting Wavelength : Automatic
Spectral Bandwidth : 4 nm
Wavelength Accuracy : ± 0.5 nm
Wavelength Range : 190 ~ 1100 nm
Spectral Bandwidth : 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : 0.2 nm
Wavelength Range : 330 to 1000 nm
Spectral Bandwidth : 5 nm
Wavelength Accuracy : ± 2 nm
Wavelength Repeatability : ≤ 1.0 nm
Wavelength Range : 335 ~ 1000 nm
Spectral Bandwidth : 4 nm
Wavelength Accuracy : ± 2 nm
Wavelength Repeatability : 1 nm
Wavelength Range : 325 ~ 1000 nm
Setting Wavelength : Automatic
Spectral Bandwidth : 2 nm
Wavelength Accuracy : ± 1.0 nm
Wavelength Range : 320 ~ 1100 nm
Spectral Bandwidth : 4 nm
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.2 nm
Wavelength Range : 320 ~ 1000 nm
Spectral Bandwidth : 2 nm
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.2 nm
Photometry : Single Beam
Monochromatic Type : Czerny-Turner
Wavelength range : 340 to 1000nm
Spectral bandwidth : 5 nm
Photometry : Single Beam
Monochromatic Type : Czerny-Turner
Wavelength range : 325 to 1000nm
Spectral bandwidth : 2 nm
Wavelength range : 320 to 1100 nm
Spectral bandwidth : 2.0 nm
Wavelength Accuracy : ± 0.8 nm
Wavelength Repeatability : ≤ 0.3 nm
Illumination system : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
Illumination light source : CLED
Sensor : Dual light path sensor array
Illumination system : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
Illumination light source : CLED
Sensor : Dual light path sensor array
Illumination system : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere : 15.2 cm, alvan diffused reflection surface coating
Illumination light source : CLED
Sensor : Dual light path sensor array
Illumination system : d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
Illumination light source : CLED
Sensor : Dual light path sensor array
Wavelength Range : 400 nm to 700 nm
Wavelength Interval : 10 nm
Sensor : High sensitivity silicon photodiode
Light Source : LED
Wavelength Range : 360 nm to 780 nm
Wavelength Pitch : 10 nm
Sensor : Silicon Photodiode Array
Grating Method : Concave Grating
Illumination : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
Sensor : Blue light enhanced sensor array
Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
Illumination : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab Maximum:0.03
Sensor : Dual light path sensor array
Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
Illumination : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
Sensor : Photoelectric diode sensor
Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
Illumination : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
Sensor : Photoelectric diode sensor
Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
Illumination : Observation angles 2°/10° Illumination: d/8 (Diffused lighting, 8° observation angle) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
Sensor : Dual light path sensor array
Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
Illumination : 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab
Sensor : High sensitivity silicon photodiode
Test angle : -
Illumination : 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab
Sensor : High sensitivity silicon photodiode
Test angle : 60°
Optical Geometry : D/8 (diffused illumination,8° viewing), Specular Component Included (SCI)
Integrating Sphere Size : Φ 40 mm
Light Source : LED (Full band balanced LED)
Color Spaces and Indices : Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strength
Optical Geometry : D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded)
Integrating Sphere Size : Φ 40 mm
Light Source : LED (Full band balanced LED)
Color Spaces and Indices : Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strength
Reflect : 8º(diffused illumination, 8 degree viewing angle)
Optical Geometry : SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source
Standards : ISO7724-1, ASTM E1164, DIN5033 Teil7
Integrating Sphere Size : Φ 40 mm
Reflect : 8º(diffused illumination, 8 degree viewing angle)
Optical Geometry : SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source
Standards : ISO7724-1, ASTM E1164, DIN5033 Teil7
Integrating Sphere Size : Φ 40 mm
Measuring geometry : D/8, SCI/SCE
Spectroscopic method : Grating spectroscopy
Sensor : Dual column high precision CMOS array sensor
Repeatability : ≤0.02
Wavelength Range : 900 nm to 2500 nm
Wavelength Accuracy : ≤ 0.2
Wavelength Reproducibility : ≤ 0.05
Bandwidth : 8 nm
Light source : 150 W Xenon lamp
Excitation wavelength : 200 nm to 900 nm
Emission wavelength : 200 nm to 900 nm
Excitation slit : 2 nm, 5 nm, 10 nm, 20 nm
Excitation Source : 150 W Xenon Lamp
Excitation Wavelength : 200 nm to 900 nm
Excitation Slit : 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Emission Slit : 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Light source : 150 W Xenon lamp
Excitation wavelength : 200 nm to 900 nm
Emission wavelength : 200 nm to 900 nm
Excitation slit : 2 nm, 5 nm, 10 nm, 20 nm
Light Source : 150W Xenon lamp
Excitation Wavelength : 200 to 900nm or zero-stage light
Bandwidth : EX \ EM: 1.0nm, 2.5nm, 5nm, 10nm, 20nm
Sensitivity : > 200:1 water Raman peak (P-P)
Optical system : Double Beam, Grating 1200 lines/mm
Wavelength Range : 190 nm to 1100 nm
Spectral Bandwidth : 2 nm
Wavelength Accuracy : ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system : Double Beam, Grating 1200 lines/mm
Wavelength Range : 190 nm to 1100 nm
Spectral Bandwidth : 1 nm
Wavelength Accuracy : ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system : Double Beam, Grating 1200 lines/mm
Wavelength Range : 190 nm to 1100 nm
Spectral Bandwidth : 2 nm
Wavelength Accuracy : ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system : Double Beam, Grating 1200 lines/mm
Wavelength Range : 190 nm to 1100 nm
Spectral Bandwidth : 1 nm
Wavelength Accuracy : ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 2 nm
Wavelength Accuracy : ±1 nm
Wavelength Repeatability : ≤0.5 nm