Auto Chemistry Analyzer LACA-A21 is a bench top, fully automated chemistry analyzer with a throughput of 200 tests per hour. This is an ideal chemistry analyzer for mid to high volume hospitals and laboratories with an increased-on board testing, reduced sample volume and easy operation for laboratories around the world. The user-friendly interface provides a long-life platform for analytical excellence. This system includes reagents, controls and calibrators along with standardized test menus, assay protocols, instrument processes and reference ranges that reduce operator variation and provide consistent quality results.
Request QuoteThroughput | 200 tests/hour |
Sample Volume | 2-70 µl |
Reagent Volume | 20-350 µl |
Sample Positions | 49 sample positions |
Reagent Positions | 56 reagent positions |
Wavelength | 340,405,450,510,546,578,630,700nm |
Absorbance | 0~3.0 Abs |
Humidity | 30-80% |
Washing | Automatic cuvettes washing |
Probe Washing | Automatic washing interior and exterior |
Reagent Cooling | Refrigerated tray with independent switch |
Cuvettes | 120 reusable cuvettes, optical length 6mm |
Mixed Probe | Independent stirring |
Stat Function | Yes |
Light Source | 12V/30W halogen lamp |
Spectrophotometry | Post-spectral spectrophotometry |
Calibration | Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Index, Logarithm, Logit-4P,Logit-5 |
Quality Control | Real-time QC, Westward multi rule, Cumulative sum check, Twin Plot(2D) |
Software | Windows 7/8/10 LIS system available |
LIS System | Bi-direction, support HL7 protocol |
Interface | LAN port access |
Printer | External, multiple reporting mode available |
Temperature | 10 - 30°C |
Temperature Control | 37±0.1°C, real time monitor |
Water Consumption | Deionized water: 5 L/H |
Power Supply | AC220V±10%, 60/50Hz,, 110V±10%, 60Hz, 300W |
External Dimension (W×D×H) | 950x612x510 mm |
Package Dimension (W×D×H) | 1118x728x1151 mm |
Net Weight | 75 kg |
Gross Weight | 130 kg |
This device is used in many Biology and Histopathology Laboratories to extract the serum, plasma, urine or any other body fluid, Research institutes etc.
Model | Throughput | Sample Volume | Reagent Volume | Sample Positions | Reagent Positions | Wavelength | Absorbance | Humidity | Washing | Probe Washing | Reagent Cooling | Cuvettes | Mixed Probe | Stat Function | Light Source | Spectrophotometry | Calibration | Quality Control | Software | LIS System | Interface | Printer | Temperature | Temperature Control | Water Consumption | Power Supply | External Dimension (W×D×H) | Package Dimension (W×D×H) | Net Weight | Gross Weight |
LACA-A10 | 400 tests/hour | 2 to 70 µl | 20 to 350 µl | 60/90 sample positions | 45 reagent positions | 340,405,450,510,546,578,630,700nm | 0~3.0 Abs | 30 to 80% | Automatic cuvettes washing | Automatic washing interior and exterior | Refrigerated tray with independent switch | 120 reusable cuvettes, optical length 6mm | Independent stirring | Yes | 12V/30W halogen lamp | Post-spectral spectrophotometry | Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Index, Logarithm, Logit-4P,Logit-5 | Real-time QC, Westward multi rule, Cumulative sum check, Twin Plot(2D) | Windows 7/8/10, 32 or 64bit | Bi-direction, support HL7 protocol | LAN port access | External, multiple reporting mode available | 10 to 30°C | 37±0.1°C, real time monitor | Deionized water: 12L/H | AC220V±10%, 60/50Hz,, 110V±10%, 60Hz, 300W | 1167×780×1016 mm | 1348×928×1399 mm | 193 kg | 267 kg |
LACA-A11 | 600 tests/hour | 2 to 70 µl | 20 to 350 µl | 90 sample positions | 180 refrigerated reagent positions | 340,405,450,510,546,578,630,700nm | 0~3.0 Abs | 30 to 80% | Automatic cuvettes washing | Automatic washing interior and exterior | Refrigerated tray with independent switch | 120 reusable cuvettes, optical length 6mm | Independent stirring | Yes | 12V/30W halogen lamp | Post-spectral spectrophotometry | Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Index, Logarithm, Logit-4P,Logit-5 | Real-time QC, Westward multi rule, Cumulative sum check, Twin Plot(2D) | Windows 7/8/10, 32 or 64bit | Bi-direction, support HL7 protocol | LAN port access | External, multiple reporting mode available | 10 to 30°C | 37±0.1°C, real time monitor | Deionized water: 15L/H | AC220V±10%, 60/50Hz,, 110V±10%, 60Hz, 300W | 1167×780×1016 mm | 1348×928×1399 mm | 216 kg | 290 kg |
LACA-A20 | 200 tests/hour | 2 to 70 µl | 20 to 350 µl | 37 sample positions | 28 reagent positions | - | 0~3.0 Abs | 30 to 80% | Automatic cuvettes washing | Automatic washing interior and exterior | Refrigerated tray with independent switch | 48 reusable cuvettes, optical length 6mm | Independent stirring | Yes | 6V/10W halogen lamp | Post-spectral spectrophotometry | Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Index, Logarithm, Logit-4P,Logit-5 | Real-time QC, Westward multi rule, Cumulative sum check, Twin Plot(2D) | Windows 7/8/10, 32 or 64bit | Bi-direction, support HL7 protocol | LAN port access | External, multiple reporting mode available | 10 to 30°C | 37±0.1°C, real time monitor | Deionized water: 5 L/H | AC220V±10%, 60/50Hz,, 110V±10%, 60Hz, 300W | 625×425×460 mm | 721×531×855 mm | 36 kg | 55 kg |
LACA-A21 | 200 tests/hour | 2-70 µl | 20-350 µl | 49 sample positions | 56 reagent positions | 340,405,450,510,546,578,630,700nm | 0~3.0 Abs | 30-80% | Automatic cuvettes washing | Automatic washing interior and exterior | Refrigerated tray with independent switch | 120 reusable cuvettes, optical length 6mm | Independent stirring | Yes | 12V/30W halogen lamp | Post-spectral spectrophotometry | Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Index, Logarithm, Logit-4P,Logit-5 | Real-time QC, Westward multi rule, Cumulative sum check, Twin Plot(2D) | Windows 7/8/10 LIS system available | Bi-direction, support HL7 protocol | LAN port access | External, multiple reporting mode available | 10 - 30°C | 37±0.1°C, real time monitor | Deionized water: 5 L/H | AC220V±10%, 60/50Hz,, 110V±10%, 60Hz, 300W | 950x612x510 mm | 1118x728x1151 mm | 75 kg | 130 kg |
LACA-A30 | 800 tests/hour, 1200 tests/hour with ISE | 2 to 70 µl | 20 to 350 µl | 150 sample positions | 180 refrigerated reagent positions | 340 to 800 nm | -0.3~3.3 Abs | 30 to 80% | Automatic cuvettes washing | Automatic washing interior and exterior | Refrigerated tray with independent switch | 160 reusable cuvettes, optical length 6mm | Independent stirring | Yes | 12V/20W halogen lamp/fiber brag | Post-spectral spectrophotometry | Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Index, Logarithm, Logit-4P,Logit-5 | Real-time QC, Westward multi rule, Cumulative sum check, Twin Plot(2D) | Windows 7/8/10, 32 or 64bit | Bi-direction, support HL7 protocol | LAN port access | External, multiple reporting mode available | 10 to 30°C | 37±0.1°C, real time monitor | Deionized water: 20L/H | AC220V±10%, 60/50Hz,, 110V±10%, 60Hz, 1500 W | 1360×791×1157 mm | 1348×928×1399 mm | 286 kg | 390 kg |
LACA-A40 | 120 tests/hr | - | - | - | - | 340, 405, 450, 510, 546, 578, 630,700 nm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | RS-232 | Internal thermal sensitive printer | - | - | - | - | - | - | - | - |