Auto Chemistry Analyzer LACA-A40 is a sophisticated instrument designed to perform biochemical analysis. It automates the analysis, providing accurate and timely results for patient diagnosis and monitoring. Analyzer conducts tests with a high degree of accuracy to assess liver, kidney, lipid, and cardiac function. Excellent detection mechanism guarantees minimal human assistance. Automatic washing function ensures efficiency and prevents cross-contamination between samples.
Request QuoteThroughput | 120 tests/hr |
Test parameters | ALT, AST, ALP, T-BIL, D-BIL, TP, ALB, CHE, Nh3, BUN, CRE, UA, URE, γ GT, T-CHO, TG, HDL-C, LDL-C, CK, CK-MB, LDH, GLU, AMS, Anti-CCP, ASO, CRP, D-dimer, HbA1c, RF, SAA, B2M, Cys-C, LP(a), mAIb, MB, NGAL, RBP |
Sample volume | 2 to 30 µL, 0.1 µL increasing |
Reagent volume | 20 to 350 µL, 0.1 µL increasing |
Analysis methods | Kinetic, End point, Fixed Time, Turbidimetry, Absorbance |
Sample positions | 24 + 5 |
Calibration position | 1 |
QC position | 1 |
ST position | 1 |
Reagent positions | 54 (27 for 6 ml, 27 for 24 ml) |
Cuvette positions | 81 |
Wavelength | 340, 405, 450, 510, 546, 578, 630,700 nm |
Absorbance range | 0 to 4.000 Abs |
Absorbance precision | Inside 0.00001Abs |
Repeatability CV | <1% |
Carry over | <0.1% |
Water consumption for automatic washing mode | 5 L/hr |
Water consumption for disposable cuvette mode | 2.5 L/hr |
Quality control curve | x̅, SD, CV%, L-J quality control curve for every test item |
Printer | Internal thermal sensitive printer |
Interface | RS-232 |
Power supply | 100 to 240 VAC, 50/60 Hz, 100 VA |
Auto chemistry analyzers play a crucial role in clinical laboratories and other scientific settings including fields like hematology, endocrinology, urinalysis, toxicology, research and development.
Model | Throughput | Test parameters | Sample volume | Reagent volume | Analysis methods | Sample positions | Calibration position | QC position | ST position | Reagent positions | Cuvette positions | Wavelength | Absorbance range | Absorbance precision | Repeatability CV | Carry over | Water consumption for automatic washing mode | Water consumption for disposable cuvette mode | Quality control curve | Printer | Interface | Power supply |
LACA-A10 | 400 tests/hour | - | - | - | - | - | - | - | - | - | - | 340,405,450,510,546,578,630,700nm | - | - | - | - | - | - | - | External, multiple reporting mode available | LAN port access | - |
LACA-A11 | 600 tests/hour | - | - | - | - | - | - | - | - | - | - | 340,405,450,510,546,578,630,700nm | - | - | - | - | - | - | - | External, multiple reporting mode available | LAN port access | - |
LACA-A20 | 200 tests/hour | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | External, multiple reporting mode available | LAN port access | - |
LACA-A21 | 200 tests/hour | - | - | - | - | - | - | - | - | - | - | 340,405,450,510,546,578,630,700nm | - | - | - | - | - | - | - | External, multiple reporting mode available | LAN port access | - |
LACA-A30 | 800 tests/hour, 1200 tests/hour with ISE | - | - | - | - | - | - | - | - | - | - | 340 to 800 nm | - | - | - | - | - | - | - | External, multiple reporting mode available | LAN port access | - |
LACA-A40 | 120 tests/hr | ALT, AST, ALP, T-BIL, D-BIL, TP, ALB, CHE, Nh3, BUN, CRE, UA, URE, γ GT, T-CHO, TG, HDL-C, LDL-C, CK, CK-MB, LDH, GLU, AMS, Anti-CCP, ASO, CRP, D-dimer, HbA1c, RF, SAA, B2M, Cys-C, LP(a), mAIb, MB, NGAL, RBP | 2 to 30 µL, 0.1 µL increasing | 20 to 350 µL, 0.1 µL increasing | Kinetic, End point, Fixed Time, Turbidimetry, Absorbance | 24 + 5 | 1 | 1 | 1 | 54 (27 for 6 ml, 27 for 24 ml) | 81 | 340, 405, 450, 510, 546, 578, 630,700 nm | 0 to 4.000 Abs | Inside 0.00001Abs | <1% | <0.1% | 5 L/hr | 2.5 L/hr | x̅, SD, CV%, L-J quality control curve for every test item | Internal thermal sensitive printer | RS-232 | 100 to 240 VAC, 50/60 Hz, 100 VA |