Automatic Tag Closed Flash Point Tester LACF-A10

Automatic Tag Closed Flash Point Tester LACF-A10

Automatic Tag Closed Flash Point Tester LACF-A10 is a highly automated machine with -50°C lowest flash point and simple operations. Used to determine flash point of liquids with viscosity below 5.5 cSt (mm2/s) at 40°C (104°F) or below 9.5 cSt (mm2/s) at 25°C (77°F) and flash point below 93°C (200°F) . Test method is complied with ASTM D56 international standard.

Request Quote
Experimental temperature range -50 to 70°C
Test sample volume 50 ml
Ambient temperature range 10 to 40°C
Humidity ≤ 85%
Ignition gas source Pipelined gas or LPG
Gas pressure < 10 kPa
Cooling method 2 Danfoss compressor refrigeration
Temperature Sensor Glass PT100 sensor
Display Touch screen LCD display
Printing method Thermal printer
Dimension 700 × 700 × 750 mm
Weight 110 kg
Power supply AC 200 V ± 10 % 50 Hz
Power 1500 W
  • Fast cooling speed
  • Equipped with liquid position overflow port, filling port
  • High depth testing at -50°C (lowest flash point) for test sample
  • Adopted with stainless steel, anti-aging gas circuit
  • 50 ml Test sample volume

Used in analysis of flash point of materials at low temperature value across petroleum, chemical, oil, paint and other industries.

Models of Automatic Tag Closed Flash Point Tester

Labtron Automatic Tag Closed Flash Point Tester determine flash point of liquid materials at experimental temperature ranging from -50℃ to 70℃. They reduce human error and increases efficiency by automating heating and testing process. Their ability to test several samples in succession, enhances throughput. They test liquid in closed environment, preventing escape of vapors and providing more accurate reading. Our Automatic Tag Closed Flash Point Tester is versatile in petroleum industry, research and development and for transportation safety.

Automatic Tag Closed Flash Point Tester LACF-A11

Automatic Tag Closed Flash Point Tester LACF-A11

  • Flash Point Temperature Range : -35℃ to 105℃
  • Tested Flash Point Temperature Accuracy : ±0.5℃ (≤100℃); ±2℃ (>100℃)
  • Sample Volume : 2 ml
  • Heating Rate : 5℃ /min
Automatic Tag Closed Flash Point Tester LACF-A10 FAQ's
  • Labtron Automatic Tag Closed Flash Point Tester LACF-A10 uses the closed cup method to limit vapor loss during testing, delivering more accurate and lower flash point readings compared to open cup methods. The closed system simulates real-world storage and transport conditions where vapors are confined. This makes it essential for evaluating the safety risks of volatile substances. The Tag closed cup design in the tester ensures higher sensitivity, repeatability, and compliance with ASTM D56 standards.

  • Our Automatic Tag Closed Flash Point Tester LACF-A10 may fail to detect a flash point if the sample volume is incorrect or the test chamber is not properly sealed. Ensure the ignition source is functioning and the gas supply is within the recommended pressure range. Also, check that the cooling system is active, particularly for low-temperature samples. Regular cleaning, maintenance, and calibration of the tester help prevent such issues and maintain reliable performance.

  • The Automatic Tag Closed Flash Point Tester LACF-A10 automatically halts operation during a power failure, preserving its last known status. Once power returns, the system must be restarted manually and the test repeated to ensure accuracy. It is recommended to connect the tester to a voltage stabilizer or UPS to protect against such interruptions. The rugged design safeguards the instrument's internal components from electrical damage.

  • The Automatic Tag Closed Flash Point Tester LACF-A10 is suitable for testing liquids with viscosities up to 5.5 cSt at 40?°C or 9.5 cSt at 25?°C. For samples exceeding this range, proper vaporization and ignition may be compromised, affecting accuracy. The device is best used for low to moderately viscous samples such as fuels, alcohols, and solvents. For high-viscosity materials, pre-treatment or alternative testing methods may be required.

  • Labtron Automatic Tag Closed Flash Point Tester LACF-A10 enhances sample safety through its dedicated filling port and overflow outlet, which help maintain accurate sample volume while preventing spills. The closed test chamber design limits vapor exposure, reducing the risk of fire or inhalation of hazardous fumes. Additionally, the automatic ignition system eliminates open flame use, improving operator safety. These built-in features make the tester ideal for routine, safe testing in lab environments.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.