Request A Quote
Benchtop PH Meter LBPM-E11

Benchtop PH Meter LBPM-E11

Benchtop pH Meter LBPM-E11 offers a pH resolution of 0.001, enabling precise detection of minute pH variations. The device has a pH Calibration Point of 1 to 3 points, ensuring accurate pH measurements across a wide range of samples. It features customizable pH standard solutions, selecting calibration buffers that match their specific measurement range. Our benchtop pH Meter includes an automatic power-off function for conserving energy and extending the device's lifespan. 

Benchtop pH Meter LBPM-E11_Top View
Benchtop pH Meter LBPM-E11_Top View
Request Quote
pH Range 2.00 to 18.00 pH
pH Resolution 0.01
pH Accuracy ± 0.01
Temperature Range -5°C to 110°C
Temperature Resolution/Accuracy 0.1°C / ±0.2°C
Display Screen LCD, 6 inches
pH Calibration Point 1 to 3 points
pH Standard Recognition 3 pH Standard Solutions (4.00, 6.86, 9.18)
Temperature Compensation Manual
Power Supply AC Adapter, 100 V to 240V Input, DC9V Output
Product Dimension 242 × 196 × 68 mm
Weight 900g
  • Wide Power Input Range

  • Electrode Stand Provided

  • Built-in Reaction Timer

  • Automatic Buffer Recognition

  • Data Logging Capability

Benchtop pH Meter LBPM-E11 is a laboratory-grade instrument designed to precisely measure the acidity or alkalinity (pH) of liquid or semi-solid sample. It is applied in cosmetics, agriculture and soil sciences for assessing pH levels

Models of Benchtop pH Meter

Labtron Benchtop pH Meter is versatile for measuring hydrogen ions from -2.00 to 20.00. They feature glass and reference electrode that produces reliable and reproducible results. Their digital display provides real-time readings, with additional information such as thermal condition and calibration status. They are equipped with temperature compensation system which adjusts readings based on temperature of solution being tested. Our Benchtop pH Meter measures acidity readings for cosmetics, aquaculture, food testing and environmental monitoring.

Benchtop pH Meter LBPM-A11

Benchtop pH Meter LBPM-A11

  • pH measurement range : 0.00 to 14.00 pH
  • pH accuracy : ± 0.01 pH
  • pH resolution : 0.01 pH
  • Calibration points : 2 points
Benchtop pH Meter LBPM-A12

Benchtop pH Meter LBPM-A12

  • pH Measuring Range : -2 to 16 pH
  • pH Resolution : 0.01 pH
  • pH Indication Error / Accuracy : ±0.03 pH
  • ORP / mV Range : ±1900 mV
Benchtop PH Meter LBPM-E12

Benchtop PH Meter LBPM-E12

  • pH Range : 2.000 to 20.000 pH
  • pH Resolution : 0.001
  • pH Accuracy : ±0.002
  • Temperature Range : 10.0° C to 135.0℃ / 14.0º F to 275.0º F
Benchtop pH Meter LBPM-C11
Benchtop pH Meter LBPM-C11
  • pH Measuring Range : -2.0 to 19.99 pH
  • pH Accuracy : Meter: ±0.01 pH; Complete Kit: ±0.02 pH
  • pH Resolution : 0.1 / 0.01 pH
  • Calibration Points : 1, 2, 3 points
Benchtop pH Meter LBPM-A20
Benchtop pH Meter LBPM-A20
  • pH measurement range : -1.00 to 15.00 pH
  • pH accuracy : ± 0.01 pH
  • pH resolution : 0.01 pH
  • Calibration points : 1-3 points
Benchtop pH Meter LBPM-B12

Benchtop pH Meter LBPM-B12

  • pH Range : -2.000 to 20.000 pH
  • pH Resolution : 0.1, 0.01, 0.001pH
  • pH Accuracy : ±0.002 pH
  • pH Calibration Points : Up to 5
Benchtop PH Meter LBPM-E10

Benchtop PH Meter LBPM-E10

  • pH Range : 0.00 to 14.00 pH
  • pH Resolution : 0.01pH
  • pH Accuracy : ± 0.01
  • Display Screen : LCD, 6.0 inches
Benchtop PH Meter LBPM-C10

Benchtop PH Meter LBPM-C10

  • pH Measuring Range : -2.000 to 18.000 pH
  • pH Accuracy : ±0.01 pH
  • pH Resolution : 0.001 / 0.01 pH
  • Calibration Points : 1, 2, 3 points, automatic

Benchtop PH Meter LBPM-E11 FAQ's
  • Labtron supplies premium benchtop pH Meter. Low ionic strength solutions, such as distilled water or deionized water, can yield unstable or inaccurate pH readings. This is because the low conductivity of such solutions interferes with the electrode’s ability to establish a stable junction potential. Use specialized low ionic strength electrodes or double junction electrodes to improve stability. Stirring the sample gently can enhance response time and accuracy. Allow extra time for the reading to stabilize, as it may be slower than in typical samples. Calibration should be performed with standard buffers that are close in ionic strength to the sample for better accuracy. Avoid prolonged exposure to low conductivity solutions, as they can dehydrate the electrode. Always rinse and recondition the electrode afterward. For high-precision tasks, consider adjusting ionic strength using an inert electrolyte like KCl if appropriate for the application.

  • Labtron supplies advanced models of Benchtop pH Meters. Reference electrode serves as a stable reference potential against which the pH electrode measures hydrogen ion activity. Its stability directly influences the accuracy and reliability of pH measurements. Most benchtop meters use a silver/silver chloride or calomel reference electrode combined with a junction to maintain electrical contact with the sample. If the reference electrode becomes clogged, contaminated, or dry, it causes erratic readings or slow response. A double junction reference design helps isolate the internal electrolyte from aggressive samples, extending electrode life and maintaining stable potential. Regular maintenance includes checking and refilling the reference electrolyte if applicable. The choice of reference electrode type depends on sample composition and required precision. A faulty reference electrode is often the root cause of measurement drift or instability, highlighting its crucial role in pH measurement systems.

  • Labtron supplies premium Benchtop pH Meters. Ionic strength affects the activity of hydrogen ions, which in turn impacts pH measurements. In solutions with low ionic strength, such as ultra-pure or distilled water, the electrode may exhibit unstable or drifting readings due to insufficient ion conductivity. Conversely, very high ionic strength samples, like brines or seawater, can cause junction potentials to fluctuate, leading to inaccuracies. To compensate, specialized electrodes with double junctions or porous ceramic junctions are recommended for challenging matrices. Calibrating the pH meter using buffer solutions that closely resemble the sample’s ionic strength improves accuracy. Additionally, careful electrode maintenance and proper temperature compensation are critical to reduce ionic interference.

  • Labtron’s Benchtop pH meters typically offer greater measurement accuracy, stability, and enhanced features compared to handheld models. They often incorporate larger, high-resolution displays and user-friendly interfaces, enabling easier calibration and data management. Benchtop meters support multiple calibration points and advanced temperature compensation, which improves precision in critical applications. Additionally, they frequently include GLP compliance features for audit trails, data logging, and connectivity options such as USB or Bluetooth for seamless data transfer. The robust design of benchtop units provides better resistance to laboratory conditions, such as spills or vibrations. For laboratories requiring consistent, high-throughput pH testing, benchtop meters deliver reliable performance and superior durability, justifying their preference in research and quality control environments.

  • Response time is crucial as it determines how quickly a benchtop pH meter stabilizes on a pH reading, affecting workflow efficiency and measurement reliability. A fast response time (typically under 10 seconds) enables quicker sample analysis and higher throughput in busy laboratories. Response time depends largely on the electrode’s condition, with fouled or aging electrodes responding more slowly. Sample matrix viscosity, temperature, and ionic strength also influence electrode response; viscous or low ionic strength samples can slow stabilization. Proper electrode maintenance, including cleaning and hydration, optimizes response speed. Modern benchtop meters often feature algorithms to detect stable readings automatically, reducing operator guesswork. Consistent response time helps improve reproducibility and accuracy in routine and research measurements.

Post your question?

Our experts are here to help!

Benchtop pH Meter:
Benchtop pH Meter LBPM-A11, Benchtop pH Meter LBPM-A12, Benchtop PH Meter LBPM-E12, Benchtop pH Meter LBPM-C11, Benchtop pH Meter LBPM-A20, Benchtop pH Meter LBPM-B12, Benchtop PH Meter LBPM-E10, Benchtop PH Meter LBPM-C10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608