| pH Range | 2.00 to 18.00 pH |
| pH Resolution | 0.01 |
| pH Accuracy | ± 0.01 |
| Temperature Range | -5°C to 110°C |
| Temperature Resolution/Accuracy | 0.1°C / ±0.2°C |
| Display Screen | LCD, 6 inches |
| pH Calibration Point | 1 to 3 points |
| pH Standard Recognition | 3 pH Standard Solutions (4.00, 6.86, 9.18) |
| Temperature Compensation | Manual |
| Power Supply | AC Adapter, 100 V to 240V Input, DC9V Output |
| Product Dimension | 242 × 196 × 68 mm |
| Weight | 900g |
Wide Power Input Range
Electrode Stand Provided
Built-in Reaction Timer
Automatic Buffer Recognition
Data Logging Capability
Benchtop pH Meter LBPM-E11 is a laboratory-grade instrument designed to precisely measure the acidity or alkalinity (pH) of liquid or semi-solid sample. It is applied in cosmetics, agriculture and soil sciences for assessing pH levels
Labtron Benchtop pH Meter is versatile for measuring hydrogen ions from -2.00 to 20.00. They feature glass and reference electrode that produces reliable and reproducible results. Their digital display provides real-time readings, with additional information such as thermal condition and calibration status. They are equipped with temperature compensation system which adjusts readings based on temperature of solution being tested. Our Benchtop pH Meter measures acidity readings for cosmetics, aquaculture, food testing and environmental monitoring.







Labtron supplies premium benchtop pH Meter. Low ionic strength solutions, such as distilled water or deionized water, can yield unstable or inaccurate pH readings. This is because the low conductivity of such solutions interferes with the electrode’s ability to establish a stable junction potential. Use specialized low ionic strength electrodes or double junction electrodes to improve stability. Stirring the sample gently can enhance response time and accuracy. Allow extra time for the reading to stabilize, as it may be slower than in typical samples. Calibration should be performed with standard buffers that are close in ionic strength to the sample for better accuracy. Avoid prolonged exposure to low conductivity solutions, as they can dehydrate the electrode. Always rinse and recondition the electrode afterward. For high-precision tasks, consider adjusting ionic strength using an inert electrolyte like KCl if appropriate for the application.
Labtron supplies advanced models of Benchtop pH Meters. Reference electrode serves as a stable reference potential against which the pH electrode measures hydrogen ion activity. Its stability directly influences the accuracy and reliability of pH measurements. Most benchtop meters use a silver/silver chloride or calomel reference electrode combined with a junction to maintain electrical contact with the sample. If the reference electrode becomes clogged, contaminated, or dry, it causes erratic readings or slow response. A double junction reference design helps isolate the internal electrolyte from aggressive samples, extending electrode life and maintaining stable potential. Regular maintenance includes checking and refilling the reference electrolyte if applicable. The choice of reference electrode type depends on sample composition and required precision. A faulty reference electrode is often the root cause of measurement drift or instability, highlighting its crucial role in pH measurement systems.
Labtron supplies premium Benchtop pH Meters. Ionic strength affects the activity of hydrogen ions, which in turn impacts pH measurements. In solutions with low ionic strength, such as ultra-pure or distilled water, the electrode may exhibit unstable or drifting readings due to insufficient ion conductivity. Conversely, very high ionic strength samples, like brines or seawater, can cause junction potentials to fluctuate, leading to inaccuracies. To compensate, specialized electrodes with double junctions or porous ceramic junctions are recommended for challenging matrices. Calibrating the pH meter using buffer solutions that closely resemble the sample’s ionic strength improves accuracy. Additionally, careful electrode maintenance and proper temperature compensation are critical to reduce ionic interference.
Labtron’s Benchtop pH meters typically offer greater measurement accuracy, stability, and enhanced features compared to handheld models. They often incorporate larger, high-resolution displays and user-friendly interfaces, enabling easier calibration and data management. Benchtop meters support multiple calibration points and advanced temperature compensation, which improves precision in critical applications. Additionally, they frequently include GLP compliance features for audit trails, data logging, and connectivity options such as USB or Bluetooth for seamless data transfer. The robust design of benchtop units provides better resistance to laboratory conditions, such as spills or vibrations. For laboratories requiring consistent, high-throughput pH testing, benchtop meters deliver reliable performance and superior durability, justifying their preference in research and quality control environments.
Response time is crucial as it determines how quickly a benchtop pH meter stabilizes on a pH reading, affecting workflow efficiency and measurement reliability. A fast response time (typically under 10 seconds) enables quicker sample analysis and higher throughput in busy laboratories. Response time depends largely on the electrode’s condition, with fouled or aging electrodes responding more slowly. Sample matrix viscosity, temperature, and ionic strength also influence electrode response; viscous or low ionic strength samples can slow stabilization. Proper electrode maintenance, including cleaning and hydration, optimizes response speed. Modern benchtop meters often feature algorithms to detect stable readings automatically, reducing operator guesswork. Consistent response time helps improve reproducibility and accuracy in routine and research measurements.