Blood Gas Analyzer LBGS-A11

Blood Gas Analyzer LBGS-A11

Blood Gas Analyzer LBGS-A10 is a compact unit that offers test parameters of pO₂, pCO₂, pH, and HCT for blood gas analysis. It utilizes 95 µl for whole blood, 50 µl for capillary blood, and 120 µl for Glu/Lac. It allows fast and easy data output with a built-in thermal printer. Our analyzer comes with long-life maintenance-free electrodes to ensure continuous operation. Equipped with a high-resolution 10.4-inch touch screen for easy operation.

Request Quote
Sample Whole blood, Serum, Plasma, Dialysate, CSF
Sample Volume 95 µl whole blood, 50 µl capillary blood, 120 µl Glu and Lac
Analysis Time < 90s
Test Parameter pO2, pCO2, pH, and HCT
Working Temperature 15 to 30°C
Input Parameter Patient temperature, Hemoglobin, FiO2, BP
Measured Parameter Hydrogen ion activity (pH): 6.000 to 9.000 pH
Carbon dioxide: 0.667 to 26.67 kPa Partial pressure (pCO₂,): 5.0 to 200.0 mmHg
Oxygen partial pressure (PO₂,): 0 to 106.7 kPa,0 to 800.0 mmHg
Hct: 12.0 to 65.0%
B.P.: 500 to 800 mmHg
Glucose: 1.1 to 66.7 mmol/L
Lactate: 0.4 to 30.0 mmol/L
Derived Parameters pH (TC), pCO2 (TC), pO2 (TC), TCO2, HCO3, BEb, BEecf, SBC, sO2%, Ca** (7.4), TCa, AG, RI, AaDO2, O2SAT, tHb( c )
Calibration Automatic, programmable 1-point and 2-point calibration
Data Storage >10000 result
Display 10.4 inches TFT touch screen
Printer Built-in thermal printer
Bar Code Reader >14 kinds barcode type
Results Maximum 90s results from the aspiration, less than 120s from sample to sample
Interface RS-232, TCP/IP interface, USB port, Integrated Bar-Code Reader
Battery Nickel-metal hydride battery, 3.0 Ah
Power Supply 100 to 240 V, 50/60 Hz
Cartridge Dimension (W×D×H) 103×70×180 mm
Dimension (W×D×H) 400×344×574 mm
Weight 18 kg
  • Disposable calibrant cartridge for convenience
  • Infrared human detector ensures accuracy
  • Barcode identification for easy tracking
  • Flexible sample adaptor for syringe and capillary
  • Auto-stop analysis on QC failure
  • Gas tank-free operation with battery
  • Auto-QC cartridge replacement
  • Residue tracking facilitates efficient maintenance

Blood gas analyzers are used to measure combinations of pH, blood gas (i.e., pCO2 and pO2), electrolytes, and metabolites parameters from whole blood samples across hospital, medicine, research institutes and labs etc.

Compare Models

Model Sample Sample Volume Analysis Time Test Parameter Working Temperature Input Parameter Measured Parameter Derived Parameters Calibration Data Storage Display Printer Bar Code Reader Results Interface Battery Power Supply Cartridge Dimension (W×D×H) Dimension (W×D×H) Weight
LBGS-A10 Whole blood, Serum, Plasma, Dialysate, CSF 95 µl whole blood,50 µl capillary blood, 120 µl Glu and Lac < 90s pO2, pCO2, pH, K, Na, Cl, Ca, and HCT 15 to 30°C Patient temperature, Hemoglobin, FiO2, BP Hydrogen ion activity (pH): 6.000 to 9.000 pH
Carbon dioxide: 0.667 to 26.67 kPa
Partial pressure (pCO₂): 5.0 to 200.0 mmHg Oxygen partial pressure (PO₂): 0 to 106.7 kPa,0 to 800.0 mmHg Potassium ion (K): 0.50 to 10.00 mmol/L Sodium ion (Na): 50.0 to 200.0 mmol/L Chloride ion (Cl): 20.0 to 200.0 mmol/L Ionized calcium (Ca): 0.10 to 5.00 mmol/L Hct: 12.0 to 65.0% B.P.: 500 to 800 mmHg Glucose: 1.1 to 66.7 mmol/L Lactate: 0.4 to 30.0 mmol/L
pH (TC), pCO2 (TC), pO2 (TC), TCO2, HCO3, BEb, BEecf, SBC, sO2%, Ca** (7.4), TCa, AG, RI, AaDO2, O2SAT, tHb( c ) Automatic, programmable 1-point and 2-point calibration >10000 result 10.4 inches TFT touch screen Built-in thermal printer >14 kinds barcode type Maximum 90s results from the aspiration, less than 120s from sample to sample RS-232, TCP/IP interface, USB port, Integrated Bar-Code Reader Nickel-metal hydride battery, 3.0 Ah 100 to 240 V, 50/60 Hz 103×70×180 mm 400×344×574 mm 18 kg
LBGS-A11 Whole blood, Serum, Plasma, Dialysate, CSF 95 µl whole blood, 50 µl capillary blood, 120 µl Glu and Lac < 90s pO2, pCO2, pH, and HCT 15 to 30°C Patient temperature, Hemoglobin, FiO2, BP Hydrogen ion activity (pH): 6.000 to 9.000 pH
Carbon dioxide: 0.667 to 26.67 kPa Partial pressure (pCO₂,): 5.0 to 200.0 mmHg
Oxygen partial pressure (PO₂,): 0 to 106.7 kPa,0 to 800.0 mmHg
Hct: 12.0 to 65.0%
B.P.: 500 to 800 mmHg
Glucose: 1.1 to 66.7 mmol/L
Lactate: 0.4 to 30.0 mmol/L
pH (TC), pCO2 (TC), pO2 (TC), TCO2, HCO3, BEb, BEecf, SBC, sO2%, Ca** (7.4), TCa, AG, RI, AaDO2, O2SAT, tHb( c ) Automatic, programmable 1-point and 2-point calibration >10000 result 10.4 inches TFT touch screen Built-in thermal printer >14 kinds barcode type Maximum 90s results from the aspiration, less than 120s from sample to sample RS-232, TCP/IP interface, USB port, Integrated Bar-Code Reader Nickel-metal hydride battery, 3.0 Ah 100 to 240 V, 50/60 Hz 103×70×180 mm 400×344×574 mm 18 kg