Request A Quote
Chemiluminescence Imaging System LCIS-A23

Chemiluminescence Imaging System LCIS-A23

Labtron Chemiluminescence Imaging System LCIS-A23 is an all-in-one western blot and gel imager for capturing faint chemiluminescent signals with high sensitivity and wide dynamic range. Its high quantum efficiency CCD camera has a 12.49 × 9.99 mm sensor and 6.05 MP resolution (2750 × 2200) with 4.54 µm pixels, so even weak bands are recorded with sharp detail. Cooling to -30 °C keeps background noise low during long exposures, and 16-bit depth (65,536 grey levels) preserves subtle intensity differences for quantitative analysis. A fast F0.95 motorised lens gathers maximum light and focuses automatically, cutting exposure times for ECL western blots and other chemiluminescent assays. An integrated 10.1-inch touchscreen lets you capture, view, and adjust images without a separate computer, and the small footprint saves bench space. Chemiluminescence Imaging System LCIS-A23 suits western blotting, immunoassays, protein and nucleic acid gel imaging, and cellular studies in molecular biology, biomedical research, and university laboratories.

Request Quote
CCD Sensor Size 12.49 × 9.99 mm
Resolution 6.05 Megapixels, 2750 × 2200
Pixel Density 16bit (65536 Grey Scales)
Pixel Size 4.54 × 4.54 µm
Lens F0.95 motorized lens
Light Source LED Epi-white light × 2
UV-Transilluminator (302 nm)
White-LED Transilluminator
Display 10.1 inch touch Screen Display
Quantum efficiency ≥ 75 %
Readout noise < 5.5e- RMS
Dark current 0.0003 e/p/s
Dynamic range 4 order of magnitude
Standard Filter 590 nm filter
Filter Wheel 8 Sockets Filter Wheel
Max Image Area 260 × 210 mm
Cooling Temperature -30˚C
Software Image acquisition and analysis software
Dimension 560 × 480 × 780 mm + 380 × 350 × 490 mm
Gross Weight 39 kg
  • 10.1-inch touch screen display with user-friendly operation mode
  • ≥ 75 % High Quantum efficiency of the CCD camera
  • CCD Sensor Size offered is 12.49 × 9.99 mm, with a 6.05 MP resolution
  • Offers convenient image navigation and browsing
  • Optional attachment of different fluorescent light sources and filters
  • Automatic pixel binning technology
  • Marker image capture and composition with objective bands
  • Small footprint - takes up minimal bench space
  • Configured for maximum sensitivity to ensure even the faintest band on a blot can be captured
  • Optional full configuration system Analysis System (DNA, RNA, Protein, Chemiluminescence, Fluorescence)

Chemiluminescence Imaging System used in genetic engineering, biotechnology, molecular biology for obtaining high-quality images of DNA/RNA bands, also for protein detection, ELISA plate reading, and Chemiluminescence analysis.

Optional System Configuration of RNA, DNA, Protein, Chemiluminescence, Fluorecence System

High precise automatic exposure and automatic recognition of the gel bands
Offers one touch image acquisition and save 
Marker image capture and composition with objective bands
Automatic access of capture parameters and calculation of the density and the peak value of each band 
Convenient image navigation and browsing 
It adopts image rotation, cropping and counter color processing 
Advanced pixel binning technology 
Optional save of analysis results as excels files 
Calculation of the optical density for the quantitative analysis 
It offers optimization of the visual effects by wiping background mode

Chemiluminescence Imaging System LCIS-A23 CCD Sensor Size	12.49 × 9.99 mm Pixel Size	4.54 × 4.54 µm
Chemiluminescence Imaging System LCIS-A23 Small footprint - takes up minimal bench space

Models of Chemiluminescence Imaging System

Labtron Chemiluminescence Imaging System is specialized to detect and visualize light emitted from chemical reactions. They are equipped with specialized cameras to capture less visibility images. Their advanced radiant-sensitive detectors enhance system ability to envision faint luminescent signals. They incorporate high-performance optics for improved resolution and clarity in captured images. Our Chemiluminescence Imaging System is applicable for western blotting, immunoassay and cellular studies in biomedical research.

Chemiluminescence Imaging System LCIS-A22

Chemiluminescence Imaging System LCIS-A22

  • CCD Sensor Size : 12.49 × 9.99 mm
  • Resolution : 6.05 Megapixels, 2750 × 2200
  • Pixel Density : 16bit (65536 Grey Scales)
  • Pixel Size : 4.54 × 4.54 µm
Chemiluminescence Imaging System LCIS-A20

Chemiluminescence Imaging System LCIS-A20

  • CCD Sensor Size : 12.49 × 9.99 mm
  • Resolution : 6.05 Megapixels, 2750 × 2200
  • Pixel Density : 16bit (65536 Grey Scales)
  • Pixel Size : 4.54 × 4.54 µm
Chemiluminescence Imaging System LCIS-A10

Chemiluminescence Imaging System LCIS-A10

  • Digital Camera Type : Cooled CCD
  • Resolution : 6 Megapixels
  • Pixel Density : 16bit (65536 Grey scales)
  • Pixel Size : 4.54 × 4.54 µm
Chemiluminescence Imaging System LCIS-A21
Chemiluminescence Imaging System LCIS-A21
  • CCD Sensor Size : 12.49 × 9.99 mm
  • Resolution : 6.05 Megapixels, 2750 × 2200
  • Pixel Density : 16bit (65536 Grey Scales)
  • Pixel Size : 4.54 × 4.54 µm
Chemiluminescence Imaging System LCIS-A11
Chemiluminescence Imaging System LCIS-A11
  • Digital Camera Type : Cooled CCD
  • Resolution : 6 Megapixels
  • Pixel Density : 16bit (65536 Grey scales)
  • Pixel Size : 4.54 × 4.54 µm

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608