Horizontal Laminar flow clean bench LHCB-B13 delivers 1152 to 2376 m³/h airflow with recommended velocity of 0.3 m/s. Features durable horizontal structure with stainless steel surface allowing easy routine cleaning. Integrated UV sterilization reliably prevents contamination and enhances culture safety. Equipped with high-efficiency ironclad centrifugal fan, ensuring quiet operation and stable work. Widely used in food quality control, pharmaceutical preparation and medical device packaging.
| External Dimension (W × L × H) | 1750mm × 720mm × 1460mm |
| Internal Dimension (W × L × H) | 1680mm × 480mm × 600mm |
| Illumination | More than or equal to 300lux |
| Air Flow | 1152 to 2376 m³⁄h (Recommended speed: 0.3m/s) |
| Airflow Direction | Horizontal |
| Noise Level | Less than or equal to 65dB |
| Vibration Semi-Peak Value | Less than or equal to 5um |
| Power Supply | AC 220V/50Hz |
| Power Rating | 800W |
| Packaging Dimension (W × L × H) | 1890mm × 840mm × 1630mm |
| Weight | 160Kg |
Our Horizontal Laminar flow clean bench LHCB-B13 is widely applicable for food quality control, pharmaceutical preparation, medical device packaging and microbiological research.
Download catalog for
Horizontal Laminar Flow Clean Bench LHCB-B13 Catalog
Labtron Clean Benches are specialized for controlling and cleaning air at certain level ensuring minimal contamination. Their surface is made from non-porous materials that are easy to sanitize and resistant to microbes. They are featured with sash shields and alarms to prevent accidental exposure from hazardous agents. Their adjustable airflow system allows to set both rate and direction according to requirement. Our Clean Benches are versatile for cosmetic manufacturing, Aerospace industry, Biomedical engineering and medical research.








The Horizontal Laminar flow clean bench LHCB-B13 is featured with high efficiency ironclad centrifugal fan drives air through the HEPA filter. Filtered air exits uniformly across the rear plenum and sweeps forward horizontally. This unidirectional curtain pushes particulates away from the critical work zone. Because airflow originates behind the samples, turbulence at the front opening is minimal. The operator remains outside the clean airstream, reducing cross contamination risk. Consistent 0.3?m/s velocity maintains positive pressure inside the bench. Samples thus stay sheltered from ambient airborne contaminants throughout procedures.
Labtron’s Horizontal Laminar flow clean bench LHCB-B13 is engineered for any process demanding a particle free workspace. Food quality laboratories employ it for microbial plating, ingredient weighing, and shelf life studies. Pharmaceutical facilities rely on it during aseptic formulation, sterile filtration, and vial filling. Medical device manufacturers use the bench for clean packaging of sterilized components. R&D groups handling cell cultures or vaccine candidates appreciate its contamination control. Optics and precision instrument shops adopt it to protect lenses and sensors from dust. Any environment requiring ISO class cleanliness benefits from this versatile workstation.
The Horizontal Laminar flow clean bench LHCB-B13 provides a broad airflow range of 1?152?–?2?376?m³/h. Factory set velocity is an optimal 0.3?m/s for laminar consistency. Adjustable fan speed lets users fine tune flow to match workload needs. Stable airflow supports ISO 5 cleanliness across the entire work surface. Large LCD readout continuously shows real time airflow and system status. If velocity deviates, visual alarms alert the operator immediately. This precise control safeguards product integrity and replicability.
Horizontal Laminar flow clean bench LHCB-B13 features HEPA filter, that captures less than or equal to 99.995?% of 0.3?µm particulates. Built in UV C lamp provides surface sterilization between work sessions. Timer settings prevent accidental UV exposure during active operations. The stainless steel work zone resists chemicals and allows thorough wipe downs. Smooth corner radii eliminate dust collecting crevices and ease disinfection. Optional prefilter extends HEPA life by trapping coarse particles early. These layered defence create a consistently sterile environment for sensitive tasks.
The Horizontal Laminar flow clean bench LHCB-B13 features ironclad centrifugal fan, which is acoustically balanced for less than or equal to 65?dB noise output. Low sound levels reduce operator fatigue in open plan laboratories. Vibration semi peak value remains below 5?µm, protecting delicate weighing. A spring assisted sliding sash positions smoothly without jerks or drifts. Bright more than or equal to 300?lux LED lighting ensures excellent visibility of samples. The stainless steel surface stays cool to the touch during extended runs. All controls sit at eye level on an intuitive LCD interface.