Request A Quote
Tabletop Dangerous Liquid Detector LTLD-B10

Tabletop Dangerous Liquid Detector LTLD-B10

Tabletop Dangerous Liquid Detector LTLD-B10 can detect containers with a minimum capacity of 100 mL. It utilizes an ultra-wideband pulse microwave reflection and thermal conductivity method. This enables it to inspect various materials, including aluminum, glass, and ceramic packaging. The detector automatically identifies dangerous liquids with a high accuracy rate. Our Tabletop Dangerous Liquid Detector includes a sulfuric acid alarm that detects fumes, offering an early warning to prevent hazards and ensure safety.

Request Quote
Container Capacity ≥ 100 mL
Identify Dangerous Liquid Gasoline, kerosene, diesel, ether, isopropyl ether, petroleum ether, acetaldehyde, ethylene glycol, nitrobenzene, propylene oxide, n-heptane, perfume, acetone, benzene, toluene, xylene, dichloroethane, trichloromethyl, tetrahydrofuran, paint, n-hexane, hydrochloric acid, sulfuric acid, nitric acid, etc.
Height of Container ≥ 30 mm
Container Material Aluminum, glass, ceramic packaging liquid
Start-up Time 2.3 sec
Time for Conductive Container Within 5 sec
Time for Insulated Container Within 1sec
Humidity 0 to 90%
Working Temperature -10°C to 55°C
Atmospheric Pressure 86kPa to 106kPa
Data Storage Stores up to 10000 test results automatically
Power on Time 1 sec
Power Consumption < 20 W
Leakage Current < 5 mA
Power Supply AC 180 V to 240 V (50/60 Hz)
Dimension 350.5 × 400.5 × 195.5 mm
Weight ≤ 9 Kg
  • Adjustable Brightness
  • Self-Calibration
  • USB disk
  • LCD screen
  • Language selection
  • Alarm mode
  • Bottom testing

The Tabletop Dangerous Liquid Detector is suitable for use in safety inspection areas, including stations, subways, government agencies, stadiums, and other crowded locations.

1.5m USB cable × 1 unit
2m power cable × 1 unit
2m crossover internet cable × 1 unit
Accessories box × 1 unit
250 mL plastic sampling cup × 1 unit

Models of Dangerous Liquid Detector

Labtron manufactures highly sensitive Dangerous Liquid Detectors that identify a wide range of flammable and explosive liquids in various containers. They utilize non-invasive technologies such as electromagnetic waves, infrared spectroscopy, and ultrasonic methods. Our dangerous liquid detectors provide fast response times, delivering results in seconds. They are portable and user-friendly, making them suitable for any environment. Their simple interfaces allow for quick training, enabling efficient use in high-pressure situations. These detectors meet international safety standards and are widely used in airport security, government protocols, and hazardous material guidelines across various industries.

Handheld Liquid Detector LHLD-B10

Handheld Liquid Detector LHLD-B10

  • Detection Time : Within 1s
  • Test Bottle Volume : Greater than 50ml
  • Test Bottle Thickness : Less than 3.5mm
  • Detect Liquid Temperature : 5 to 40°C
Tabletop Dangerous Liquid Detector LTLD-A10

Tabletop Dangerous Liquid Detector LTLD-A10

  • Container Capacity : Less than or equal to 5000 ml
  • Height of Container : 30 mm
  • Container Wall Thickness : Less than 5.0 mm
  • Detectable Minimum Liquid Volume : 50 ml
Tabletop Dangerous Liquid Detector LTLD-C11

Tabletop Dangerous Liquid Detector LTLD-C11

  • Non-Metal Containers Detection Speed : 1 seconds
  • Container Detection Temperature : 5°C to 35°C
  • Storage Temperature : -40°C to 60°C
  • Operating Temperature : 15°C to 35°C
Tabletop Dangerous Liquid Detector LTLD-B11
Tabletop Dangerous Liquid Detector LTLD-B11
  • Container Material : Iron, aluminum, plastic, glass, ceramics
  • Detectable Dangerous Liquid Categories : Flammable, explosive, corrosive
  • Detectable Bottle Diameter : Ø 50 to 170 mm (plastic, glass, ceramic) Ø 50 to 80 mm (metal cans)
  • Detectable Container Capacity (Metallic and Non-metallic) : ≥ 100 ml
Tabletop Dangerous Liquid Detector LTLD-C10
Tabletop Dangerous Liquid Detector LTLD-C10
  • Minimum Detection Quantity : 100 ml
  • Non-Metal Containers Detection Speed : 1 to 2 seconds
  • Metal Containers Detection Speed : Less than or equal to 5 seconds
  • Self-Check Time : Less than or equal to 2 seconds
Handheld Liquid Detector LHLD-A10

Handheld Liquid Detector LHLD-A10

  • Container Capacity : No less than 50 mL
  • Identify Dangerous Liquid : More than 30 types, including gasoline, kerosene, diesel oil, hydrochloric acid, sulfuric acid, nitric acid, sodium hydroxide, potassium hydroxide, isopropyl ether, petroleum ether, propionaldehyde, benzene, carbon disulfide, hexane, isopropanol, nitroethane, diethylamine, trihalomethanes, ethylene glycol, xylene, and other flammable or corrosive liquids.
  • Container Size : No less than 55 mm × 15 mm
  • Container Material : Include iron, aluminum, plastic, glass, porcelain, pottery