Request A Quote
Dental Xray System LDXS-A16

Dental Xray System LDXS-A16

Dental Xray System LDXS-A16 harnesses high-frequency technology at 30 kHz to deliver precise, high-resolution imaging. Its monochromatic screen offers intuitive visual feedback during procedures, enhancing user control. Dual tube voltage and broad compatibility enable versatile diagnostics across clinical settings. This system features adjustable tube currents and optimized power consumption, ensuring both operational flexibility and energy efficiency. Our Dental Xray System combines reliability with a low environmental footprint, making it a smart choice for modern dental practices.

Dental Xray System LDXS-A16_Front view
Dental Xray System LDXS-A16_back view
Request Quote
Working Frequency 30 kHz
Screen Monochromatic Screen
Exposure Time 0.1 to 2.0 seconds
Leak Radiation ≤ 0.002 mGy/h at 1 meter distance
Tube Voltage 60 KVP or 70 KVP
Tube Current 1.5
Rated Power 100 to 300VA
Input Power AC 100 to 240V, 50/60Hz
Dimensions 11 × 14 × 16.5 cm
Gross Weight 1.7 kg
  • High-Frequency Technology
  • Wide Voltage Compatibility
  • Dual Tube Voltage Options
  • Compact and Lightweight Design
  • Low Radiation Emission

Our Dental Xray System LDXS-A16 supports a wide range of imaging needs in both general and specialized dentistry. Its adjustable settings enable tailored exposures for periapical, bitewing, and occlusal views. Compact and precise, it’s ideal for clinics, mobile units, and academic use.

Models of Dental Xray System

Labtron Dental Xray Systems employ advanced imaging to detect cavities, bone loss, and oral health issues, enabling precise treatment planning. They offer intuitive controls, rapid image processing, and seamless electronic health record integration, enhancing workflow and patient management. Reduced radiation exposure and AI-assisted imaging improve patient safety and ensure comprehensive diagnostics. Their ergonomic design and automation ensure easy operation, making them indispensable for dental professionals.

Dental Xray System LDXS-A19

Dental Xray System LDXS-A19

  • Screen : 3.5inch Touch screen
  • Working Frequency : 30 kHz
  • Exposure Time : 0.1 to 2.0 seconds
  • Leak Radiation : ≤ 0.002 mGy/h at 1 meter distance
Dental Xray System LDXS-A12

Dental Xray System LDXS-A12

  • Frequency : 30 to 100 kHz
  • Exposure Time : 0.1 to 2.5 s
  • Focal Spot to Skin Distance : 100 mm ± 10 mm
  • Focus Size : 0.7 × 0.7 mm
Dental Xray System LDXS-A22

Dental Xray System LDXS-A22

  • Frequency : 30 kHz
  • Screen : 2.4 Inch Dot Matrix screen
  • Ambient Temperature : 5°C to 40°C
  • Relative Humidity :
Dental Xray System LDXS-A13
Dental Xray System LDXS-A13
  • Frequency : 30 kHz
  • Exposure Time : 0.1 to 2 seconds
  • Focus Size : 0.7 × 0.7 mm
  • Tube Voltage : 60 kV
Dental Xray System LDXS-A15
Dental Xray System LDXS-A15
  • Frequency : 30 kHz
  • Time of Exposure : 1 to 9 seconds
  • Radiation Leakage : < 20 μGy/h
  • Environmental Temperature : 5 to 40 ℃
Dental Xray System LDXS-A26

Dental Xray System LDXS-A26

  • Frequency : 30 kHz
  • Display : 2.4 Inch Dot Matrix screen
  • Operating Temperature Range : 5°C to 40°C
  • Relative Humidity :
Dental Xray System LDXS-A10

Dental Xray System LDXS-A10

  • Focal Spot Size : 0.8 mm
  • Total Filtration : 2.5 mm AL
  • Exposure Time Range : 0.2 to 4 seconds
  • Leakage Radiation Test : ≤ 0.002 mGy/h at 1 meter
Dental Xray System LDXS-A18

Dental Xray System LDXS-A18

  • Screen : 2.4 Inch Dot Matrix screen
  • Working Frequency : 30 kHz
  • Exposure Time : 0.1 to 2.0 seconds
  • Leak Radiation : ≤ 0.002 mGy/h at 1 meter distance
Dental Xray System LDXS-A16 FAQ's
  • Dental Xray System LDXS-A16 is designed for precision imaging in dental diagnostics, offering high-frequency technology and low radiation emission for safe and efficient operation.

  • Dental Xray System LDXS-A16 equipped with a monochromatic screen that provides clear visual feedback during operation.

  • Dental Xray System LDXS-A16 minimizes radiation exposure with low leakage emission and optimized settings, ensuring safety for both patients and operators.

  • Yes, Dental Xray System LDXS-A16 can be integrated with various digital dental imaging systems for enhanced diagnostic capabilities.

  • Dental Xray Systems utilize advanced imaging technology to detect cavities, bone loss, and other oral health issues. They provide high-resolution imaging for accurate diagnosis and treatment planning.

  • Yes, Dental Xray Systems are designed with optimized radiation settings, reducing exposure while maintaining high-quality imaging. AI-assisted enhancements further improve diagnostic accuracy while prioritizing patient safety.

  • Yes, Dental Xray System supports wireless connectivity, allowing instant image transfer to computers, tablets, and cloud storage for efficient diagnostics and record-keeping.

  • Yes, automated positioning and pre-set exposure settings ensure accurate image capture, reducing retakes and improving workflow efficiency.

  • Yes, Dental Xray Systems support cloud connectivity, allowing for secure image storage and access across multiple devices for streamlined patient record management.

  • Dental Xray system eliminates the need for chemical-based film processing, reducing waste and environmental impact while offering instant digital imaging.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.