Salt Spray Test Chamber LSSC-A14 is designed as per ASTMB117, ISO9227 configurations, and is comprised with 1030 L of capacity and external 78 L salt solution tank with a brine mixing system. Features continuous/periodic spray with adjustable spray tower and quartz nozzle with high temperature, corrosion and clogging resistance. Incorporated with PID programmable touch screen controller, PT100 Ω / MV A-class sensor, Nichrome heater and Saturated air barrel, this salt spray test chamber has air source diverting device to distribute the compressed air to the opening system. With round bars and V-shaped groove sample holder, it is provided with protection against humidifier dry-combustion, over-temperature, over-current, water shortage and earth leakage. Designed with glass fiber reinforced plastics, transparent window, pneumatic switch lid, pneumatic seal and adjustable castors with brakes, this salt spray test chamber ensures long service life with high temperature and corrosion resistance.
Testing room capacity | 1030 L |
Temperature range | Ambient to +60°C |
Humidity range | 95% to 98% RH |
Temperature Fluctuation | ± 0.5 ℃ |
Temperature Deviation | ± 2.0 ℃ |
Spray deposition | 1 to 2 ml / 80 cm2 .h |
Spray type | Continuous /Periodic |
Spraying system | Atomizer tower and Spray nozzle |
Air preheating | Saturated air barrel; 31 L |
Heating element | Nichrome heater |
Salt fog collection | Fog collector and Fog measure cylinder |
Standard sample holder | 8 round bars and 7 V-shaped grooves |
Controller | PID |
Sensor | PT100 Ω / MV A-class sensor |
Housing | Glass fiber reinforced plastics |
Observation window | Glass |
Sealing | Pneumatic seal |
Protection |
Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
Maximum noise | 65 dBA |
Power supply | 220 V 50 Hz 1 P |
Water solution tank dimension (W×D×H) | 600×370×350 mm |
Observation window dimension (L×B) | 800×300 mm |
Internal dimension (W×D×H) | 1600×900×720 mm |
External dimension (W×D×H) | 2500×1300×1600 mm |
Net weight | 390 kg |
Gross weight | 560 kg |
Salt spray test chamber is used to create and maintain the salt spray (fog) test environment, and test the anti-corrosion quality of all the materials surfaces after the rust-proof of painting, coating, electroplating, anodizing and rust-proof of greasing.
Model | Testing room capacity | Temperature range | Humidity range | Temperature Fluctuation | Temperature Deviation | Spray deposition | Spray type | Spraying system | Air preheating | Heating element | Salt fog collection | Standard sample holder | Controller | Sensor | Housing | Observation window | Sealing | Protection | Maximum noise | Power supply | Water solution tank dimension (W×D×H) | Observation window dimension (L×B) | Internal dimension (W×D×H) | External dimension (W×D×H) | Net weight | Gross weight |
LSSC-B10 | - | 10 to 90°C | 30 to 98% RH | - | - | - | - | - | - | - | - | - | Programmable color LCD touch screen controller, Ethernet connection, PC Link, USB | - | - | - | - | - | 65 dBA | 380 V, 50 Hz, 3 Phase | - | - | - | - | - | 657 kg |
LSSC-A10 | 110 L | Ambient to +60°C | 95 to 98% RH | ± 0.5 ℃ | ± 2.0 ℃ | 1 to 2 ml / 80 cm2 .h | Continuous /Periodic | Atomizer tower and Spray nozzle | Saturated air barrel; 31 L | Nichrome heater | Fog collector and Fog measure cylinder | 6 round bars and 5 V-shaped grooves | PID | PT100 Ω / MV A-class sensor | Glass fiber reinforced plastics | - | Hydrostatic hood seal |
Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
65 dBA | 220 V 50 Hz 1 P | 350×180×320 mm | - | 600×460×400 mm | 1100×700×1000 mm | 110 kg | 185 kg |
LSSC-A11 | 326 L | Ambient to +60°C | 95 to 98% RH | ± 0.5 ℃ | ± 2.0 ℃ | 1 to 2 ml / 80 cm2 .h | Continuous /Periodic | Atomizer tower and Spray nozzle | Saturated air barrel; 31 L | Nichrome heater | Fog collector and Fog measure cylinder | 7 round bars and 6 V-shaped grooves | PID | PT100 Ω / MV A-class sensor | Glass fiber reinforced plastics | - | Hydrostatic hood seal |
Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
65 dBA | 220 V 50 Hz 1 P | 350×180×320 mm | - | 1000×640×510 mm | 1580×910×1200 mm | 225 kg | 260 kg |
LSSC-A12 | 410 L | Ambient to +60°C | 95 to 98% RH | ± 0.5 ℃ | ± 2.0 ℃ | 1 to 2 ml / 80 cm2 .h | Continuous /Periodic | Atomizer tower and Spray nozzle | Saturated air barrel; 31 L | Nichrome heater | Fog collector and Fog measure cylinder | 8 round bars and 7 V-shaped grooves | PID | PT100 Ω / MV A-class sensor | Glass fiber reinforced plastics | - | Hydrostatic hood seal |
Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
65 dBA | 220 V 50 Hz 1 P | 350×180×320 mm | - | 1100×750×500 mm | 1900×920×1200 mm | 260 kg | 310 kg |
LSSC-A13 | 780 L | Ambient to +60°C | 95% to 98% RH | ± 0.5 ℃ | ± 2.0 ℃ | 1 to 2 ml / 80 cm2 .h | Continuous /Periodic | Atomizer tower and Spray nozzle | Saturated air barrel; 31 L | Nichrome heater | Fog collector and Fog measure cylinder | 8 round bars and 7 V-shaped grooves | PID | PT100 Ω / MV A-class sensor | Glass fiber reinforced plastics | Glass | Pneumatic seal |
Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
65 dBA | 220 V 50 Hz 1 P | 600×370×350 mm | 800×300 mm | 1300×1000×600 mm | 2200×1200×1400 mm | 280 kg | 450 kg |
LSSC-A14 | 1030 L | Ambient to +60°C | 95% to 98% RH | ± 0.5 ℃ | ± 2.0 ℃ | 1 to 2 ml / 80 cm2 .h | Continuous /Periodic | Atomizer tower and Spray nozzle | Saturated air barrel; 31 L | Nichrome heater | Fog collector and Fog measure cylinder | 8 round bars and 7 V-shaped grooves | PID | PT100 Ω / MV A-class sensor | Glass fiber reinforced plastics | Glass | Pneumatic seal |
Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
65 dBA | 220 V 50 Hz 1 P | 600×370×350 mm | 800×300 mm | 1600×900×720 mm | 2500×1300×1600 mm | 390 kg | 560 kg |
LSSC-A15 | 1600 L | Ambient to +60°C | 95% to 98% RH | ± 0.5 ℃ | ± 2.0 ℃ | 1 to 2 ml / 80 cm2 .h | Continuous /Periodic | Atomizer tower and Spray nozzle | Saturated air barrel; 31 L | Nichrome heater | Fog collector and Fog measure cylinder | 8 round bars and 7 V-shaped grooves | PID | PT100 Ω / MV A-class sensor | Glass fiber reinforced plastics | Glass | Pneumatic seal |
Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
65 dBA | 220 V 50 Hz 1 P | 600×370×350 mm | 800×300 mm | 2000×1000×800 mm | 3000×1420×1850 mm | 480 kg | 630 kg |