Double Beam UV-Vis Spectrophotometer LUS-B50 features a spectral bandwidth of 6 nm with a wavelength accuracy of ±2 nm. It is capable of measuring time-based changes and calculating response rates. The unit utilizes stored programs for reagent and test tube testing and pre-programmed pipette testing methods. Equipped with a silicon photodiode detector and a xenon lamp light source for better performance. Our compact benchtop spectrophotometer is ideal for use in both laboratories and industrial settings.

Request Quote
Wavelength Range 190 to 1100nm
Spectral Bandwidth 6 nm
Wavelength Accuracy ± 2nm
Wavelength Repeatability ≤ 1nm
Wavelength Setting Automatic wavelength setting
Wavelength Resolution 0.1nm
Transmittance Accuracy ±0.4%T
Optical System Proportional double beam system
Grating holographic diffraction grating
Photometric Range 0 to 400%T, (-0.602 to 4.0A)
Photometric Accuracy ±0.002A (0-0.5A)
±0.004A (0.5-1A)
±0.8%T (0-100%T)
Photometric Repeatability ≤0.001A(0-0.5A)
≤0.002A(0.5-1A)
≤0.1%T(0-100%T)
Detector Double-imported silicon photodiode
Stray Light ≤0.5%T(220nm)
Baseline Drift ≤0.001A/h(500nm,0A)
Light Source Imported pulsed xenon lamp
Display Screen 5-inch color touchscreen
Display Size 480 × 272
Printout Micro-printer, PC Printer
Power Supply DC12V 3A
Packaging Dimension 400 × 420 × 300 mm
Weight 7kg
Packaging Weight 12kg
  • Automatic wavelength setting
  • Proportional double-beam optical system
  • Holographic diffraction grating
  • 5-inch color touchscreen display
  • Micro-printer and PC Printer for printing

Double Beam UV-visible spectrophotometer is used for quality control, technical assessment, and scientific exploration. It is applicable in testing, medical research, biochemistry, environmental monitoring, commodity inspection, petrochemical analysis, and beyond.

Models of Double Beam UV-Vis Spectrophotometer

Labtron UV-Vis double beam Spectrophotometers are small, tabletop devices with twin beam designs that span a wide range of wavelengths. They have silicon photodiode detectors, automatic wavelength adjustments, and tungsten and deuterium lamps. These feature LCD displays and USB ports for data storage and transportation. They provide a variety of measurement methods to satisfy various analytical needs. Our double beam spectrophotometers have exceptional performance and durability, auto calibration, user-friendly interfaces, and enhanced optics for precision.

Double Beam UV/Vis Spectrophotometer LUS-B70

Double Beam UV/Vis Spectrophotometer LUS-B70

  • Optical System : Czerny-Turner (CT) design, double beam
  • Grating : 1200 lines/mm holographic grating
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 0.5, 1, 2, 4, 5 nm (5 gears, continuously adjustable)
Double Beam UV-Vis Spectrophotometer LUS-B21

Double Beam UV-Vis Spectrophotometer LUS-B21

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 2 nm
  • Wavelength Setting : Automatic
  • Optical System : Double Beam, Grating 1200 lines/ mm
Double Beam UV-Visible Spectrophotometer LUS-B36

Double Beam UV-Visible Spectrophotometer LUS-B36

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 2 nm
  • Wavelength Setting : Automatic
  • Optical System : Double Beam, Grating 1200 lines/ mm
Double Beam UV-Vis Spectrophotometer LUS-B53
Double Beam UV-Vis Spectrophotometer LUS-B53
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 0.5, 1, 2, 4 and 5 nm
  • Wavelength Setting : Automatic
  • Optical System : Double Beam, Grating 1200 lines/ mm
Double Beam UV-Vis Spectrophotometer LUS-B51
Double Beam UV-Vis Spectrophotometer LUS-B51
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 5 nm
  • Wavelength Accuracy : ± 1.8 nm
  • Wavelength Repeatability : ≤ 1 nm
Double Beam UV-Vis Spectrophotometer LUS-B42

Double Beam UV-Vis Spectrophotometer LUS-B42

  • Wavelength Range : 190nm to 1100nm
  • Wavelength Accuracy : ± 0.3nm
  • Wavelength Repeatability : ≤ 0.1nm
  • Spectral Bandwidth : 0.5 to 6.0nm
Double Beam UV-Vis Spectrophotometer LUS-B16

Double Beam UV-Vis Spectrophotometer LUS-B16

  • Optical System : Double beam
  • Wavelength Range : 190 to 1100 nm
  • Band Width : 0.5, 1, 2, 4 nm
  • Wavelength Accuracy : ±0.3 nm
Double Beam UV-Vis Spectrophotometer LUS-B12

Double Beam UV-Vis Spectrophotometer LUS-B12

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1.8 nm
  • Optical System : Double beam, C-T monochromator,1200 L/mm holographic grating
  • Wavelength Accuracy : ±0.3 nm

Double Beam UV-Vis Spectrophotometer:
Double Beam UV/Vis Spectrophotometer LUS-B70, Double Beam UV-Vis Spectrophotometer LUS-B21, Double Beam UV-Visible Spectrophotometer LUS-B36, Double Beam UV-Vis Spectrophotometer LUS-B53, Double Beam UV-Vis Spectrophotometer LUS-B51, Double Beam UV-Vis Spectrophotometer LUS-B42, Double Beam UV-Vis Spectrophotometer LUS-B16, Double Beam UV-Vis Spectrophotometer LUS-B12, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 20 8004 3587

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.