| Evaporation Bath Type | Aluminum bath |
| Evaporation Bath Size | φ260 × 130 mm |
| Testing Holes | 5 pieces |
| Testing Cylinder Hole Size | φ51 × 70 mm |
| Working Temperature | 160℃ to 165℃ |
| Decompression Valve Working Pressure | 0.07 MPa |
| Jet Nozzle Air Flow Rate | 600 ml/s |
| Power Consumption | 3.5 kW |
| Power Supply | AC 220 V ± 10 %, 50 Hz |
| Dimension | 590 × 480 × 340 mm |
| Packing Dimension | 810 × 550 × 780 mm |
| Gross Weight | 72 Kg |
Download catalog for
Existent Gum Tester LEGT-B32 Catalog
Labtron Existent Gum Tester evaluates physical properties of gum samples. Their advanced sensors provide real-time feedback on elasticity and viscosity during testing processes. They incorporate temperature control system to maintain optimal conditions during procedure. Their automated data logging capabilities streamline record-keeping, enhancing traceability and compliance efforts significantly. Our Existent Gum Tester is utilized in food industry, pharmaceuticals, materials science, quality assurance, and consumer research to ensure product quality in chewing gum.



Labtron Existent Gum Tester LEGT-B32 measures residue by inspecting and weighing the remaining content in the evaporation beaker after testing. The difference between the initial fuel volume and the residual weight gives the gum content. The residue detected by the tester shows the fuel’s tendency to form deposits during use or storage. The lower the residue value, the better the fuel’s stability and performance.
The Existent Gum Tester LEGT-B32 is ideal for testing volatile fuels such as motor gasoline, aviation gasoline, and fuel blends. The device is not recommended for diesel or heavy oils due to different testing needs. It can replicate high-temperature engine conditions using air-jet evaporation. The instrument is essential for identifying gum-forming tendencies in light fuels.
Our Existent Gum Tester LEGT-B32 allows manual control of airflow using individual float-type flow meters for each sample. The temperature is automatically maintained within the standard 160–165°C range for reliable operation. Our device offers flexibility to adjust flow for different test conditions while maintaining temperature stability. The settings should follow ASTM D381 recommendations to ensure valid, repeatable results.
Labtron Existent Gum Tester LEGT-B32 may produce high residue levels if the fuel is contaminated or the equipment is not properly cleaned. The issue could also result from unstable temperature or uneven airflow during the test. Our recommendation is to inspect calibration, verify equipment cleanliness, and repeat the procedure if needed. The test results obtained from this device should be documented for traceability and troubleshooting.
The Existent Gum Tester LEGT-B32 includes individual float-type flow meters that visually indicate airflow (approx. 600ml/s per nozzle). The user can adjust valves to maintain the float in the calibrated range for each sample. Our system supports periodic verification using external flow calibrators to ensure airflow consistency. The accuracy of airflow is critical in order to achieve uniform evaporation and reliable results.
Our Existent Gum Tester LEGT-B32 operates at high temperatures, so users must wear heat-resistant gloves when handling sample holders. The aluminum bath of the tester can reach up to 165°C during testing. Our advice is to allow the unit to cool fully before cleaning or removing parts. The metal surfaces near the bath should be avoided during operation, and safety warnings should be followed at all times.