| Lasers | Up to 3 lasers: 405 nm (100 mW), 488 nm (60 mW), 638 nm (80 mW) |
| Sample Acquisition Rate | Greater than 50,000 events/sec |
| Forward and Side Scatter Resolution | FSC: < 0.45 µm |
| Sensitivity | FITC < 50 MESF; PE < 30 MESF; APC < 30 MESF |
| Fluorescence Linearity | Greater than 0.99 |
| Detector | APD Detector |
| Detection Particle Range | 0.2 to 50 µm |
| Carryover Rate | Less than 0.1℃ |
| Absolute Count | Compatible with volumetric and microsphere absolute counting |
| Signal Range | Maximum 10⁷ |
| Injection Speed | Low: 15 µL/min; Medium: 30 µL/min; High: 60 µL/min; High 2: 90 µL/min; High 3: 120 µL/min |
| Adjustable Speed Range | 15 to 120 µL/min |
| Threshold Setting | Supports dual thresholds to minimize cell debris |
| Fluorescence Compensation | Automatic online/offline compensation, visual compensation tools |
| Injection Mode | Single tube manual sampling |
| Automatic Sampling | 40-tube auto sampler with single sample mixing |
| Sample Rack | 96-hole plates |
| Software | English interface; supports acquisition and |
| Computer Configuration | DELL CPU i5, 8 GB RAM, 1 TB HDD, 17-inch monitor |
| Dimensions | 760 × 450 × 470 mm |
| Weight | 40 kg |
High-speed acquisition
Submicron resolution detection
Ultra-high sensitivity
Avalanche photodiode detector
Low sample carryover
Flow Cytometer LFCM-A12 is an advanced instrument used to analyze and quantify physical and chemical characteristics of cells or particles in a fluid. It is widely applied in research laboratories, clinical diagnostics, immunology, hematology, and oncology studies.
Labtron Flow cytometer can analyze various cell properties including size, granularity, and fluorescence intensity. They help in identifying different cell types and their characteristics. They can analyze thousands of cells per second, efficiently handling large cell populations. They are incorporated with a temperature controller with the laser that enhances stability during operations. Due to their stabilized fluorescence detection signals, our flow cytometer provides more reliable data. These are essential in biological research, clinical diagnostics, and drug development.


The Flow Cytometer LFCM-A12 enhances the detection of rare populations such as CAR-T cells or minimal residual disease through its ultra-high sensitivity and broad signal range. Its fine forward and side scatter resolution helps distinguish small or dim cell populations from debris. Automatic compensation and dual threshold settings ensure clean separation of rare events, even in complex clinical matrices. The APD detector boosts signal precision and reduces background noise. Together, these features facilitate reliable identification of rare cells for accurate diagnostics and monitoring.
Yes, the Flow Cytometer LFCM-A12 is built for high-throughput workflows, it offers an autosampler with a 40-tube capacity and 96-well plate support, reducing manual handling. Adjustable injection speeds allow optimization between throughput and data quality. Automated fluorescence compensation simplifies multicolor panel setup. The English interface enables simultaneous data acquisition and analysis, yielding rapid results. Its compact design saves bench space, ideal for shared core facilities or clinical labs seeking efficient immunophenotyping.
Our Flow Cytometer LFCM-A12 is highly suitable for stem cell and CAR-T research, offering sensitive detection and broad dynamic range required for rare and heterogeneous populations. Its low carryover and dual thresholds maintain sample integrity across sequential runs. Absolute counting via volumetric or microsphere methods enables precise cell quantification in therapeutic preparations. The inclusion of three excitation lasers supports multicolor panels for discriminating diverse cell subsets, and its APD detector ensures reliable signal capture across low and high expression levels.
Labtron’s Flow Cytometer LFCM-A12 delivers reproducible data by offering robust particle detection its detection range extends from bacteria and viruses to algae. Dual thresholds effectively exclude debris common in environmental samples. With minimal carryover rates, sequential runs remain uncontaminated. Absolute counting capabilities enable accurate quantification of microorganisms. Adjustable flow rates and a wide dynamic signal range allow flexibility when handling variable sample types. Overall, it supports reliable environmental monitoring and pathogen enumeration.
Our Flow Cytometer LFCM-A12 is ideal for immunology assays due to its multicolor detection capability across three lasers and automated compensation tools. High sensitivity captures subtle fluorescence differences important in CFSE-based proliferation or low-level cytokine expression. APD detection ensures clarity even with dim markers. The software enables simultaneous acquisition and data analysis, streamlining workflow. Adjustable speeds and dual thresholds help handle variable sample types while maintaining clean data. These features facilitate accurate characterization of complex immune cell subsets.
The Flow Cytometer LFCM-A12 delivers consistent absolute counting using both volumetric and microsphere methods, giving flexibility for different workflows. Its volumetric measurement ensures accuracy when bead supplies are limited, while microspheres provide external standards. Low carryover preserves sample integrity across consecutive runs. Adjustable injection speeds accommodate varying cell concentrations. With its broad signal range and high resolution, both low-abundance and high-expression cell populations can be accurately enumerated, aiding precise hematology profiling.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom