Automatic Headspace Sampler LGSI-B10 operates with a sample heating range of 40℃ to 200℃ (customizable up to 250℃). It supports up to 20 preset samples, reducing the need for manual intervention and enhancing analytical consistency. The sampler integrates advanced fault judgment processes, automatically identifying the position of sample bottles and avoiding empty or misaligned vials. Its sample transfer lines, and dosing rings are made from high-inert deactivation materials to prevent contamination. Our sampler is designed to analyze volatile organic compounds.

Request Quote
Sample Heating Range 40℃ to 200℃ (customizable up to 250℃)
Sample Heating Range Temperature Control Accuracy 1℃
Injection Valve Heating Range 40℃ to 200℃ (customizable up to 330℃)
Injection Valve Heating Range Temperature Control Accuracy 1℃
Sample Transfer Tube Heating 40℃ to 200℃ (customizable up to 330℃)
Sample Transfer Tube Heating Temperature Control Accuracy 1℃
Relative Standard Deviation 1.5% (100 ppm aqueous ethanol solution)
Equalization Time 0 to 100 min
Pressurization Time 0 to 10 min
Sampling Time 0 to 10 min
Quantitative Ring Equilibration Time 0 to 10 min
Injection Time 0 to 10 min
Analysis Time 0 to 100 min
Blowdown Time 0 to 100 min
Volume of Quantitative Tube 1 mL (customizable up to 3 mL)
Headspace Bottles Quantity 10 mL or 20 mL
Sample Position 20 positions
Circulation of Heated Samples 20 positions
Power Consumption Peak 1000 W
Dimension 430 × 270 × 500 mm
Net Weight About 20 kg
  • One-key start

  • Automatic heating and balancing

  • No external drive gas

  • Safe and convenient to use

  • Simultaneous start of chromatography and workstation

  • Compact design

Our Automatic Headspace Sampler LGSI-B10 is used in petrochemical, environmental, food, pharmaceutical, and chemical industries for analyzing volatile organic compounds. It ensures precise detection of residual solvents, flavors, hydrocarbons, and contaminants in various samples.

Headspace bottles × 1 box

Aluminum caps and plugs × 1 pack

Sealing pliers × 1 pair

Models of GC Sampler And Injector

Labtron offers a broad range of GC Samplers and Injectors designed for precision and efficiency. Autosamplers ensure automated, high-throughput injections, while manual injectors provide cost-effective, precise control. Headspace samplers enhance VOC analysis in environmental, pharmaceutical, and forensic applications. With these advanced solutions, Labtron supports reliable and high-performance gas chromatography analysis across multiple industries. Our samplers and injectors are valuable in environmental, pharmaceutical, and food testing.

Headspace Sampler LGSI-A10

Headspace Sampler LGSI-A10

  • Sample Area Temperature Control Range : Temperature 250℃, set at 1℃ increments
  • Sample Transfer Line Temperature Control Range : Temperature 220℃, set at 1℃ increments
  • Valve Feed System Temperature Control Range : Temperature 220℃, set at 1℃ increments
  • Sample Pressurization Range : 0 to 0.4 MPa (continuously adjustable)
Automatic Headspace Sampler LGSI-B10 FAQ's
  • Our Automatic Headspace Sampler operates using the headspace sampling technique, which involves heating a sample in a sealed vial to allow volatile compounds to be released into the gaseous phase. A portion of this gas is then extracted and injected into a gas chromatograph for analysis. The device uses a positive pressure sampling method to ensure high sensitivity and stability, preventing baseline drift. It also features automated processes for sample handling, reducing errors and enhancing repeatability.

  • Using an Automatic Headspace Sampler like this offers multiple benefits, including improved accuracy, consistency, and efficiency in gas chromatography analysis. It eliminates manual errors, ensures uniform sample heating and injection, and enhances reproducibility. The sampler is compatible with various chromatographs, has a user-friendly LCD display for easy operation, and does not require external gas sources, making it convenient for laboratory use. Additionally, its high-inert deactivation materials prevent contamination, ensuring reliable results.

  • The Automatic Headspace Sampler is capable of analyzing liquid, solid, and semi-solid samples containing volatile organic compounds. It is commonly used to test for residual solvents in pharmaceuticals, volatile compounds in food and beverages, hydrocarbons in petrochemical products, and contaminants in environmental samples like water and soil. The sampler supports different headspace vial sizes, ensuring versatility across various applications.

  • Our Automatic Headspace Sampler is designed with high-inert deactivation materials in all sample transfer lines and dosing rings, preventing sample residue and cross-contamination. It also features advanced fluid judgment processing, which automatically identifies sample vial positions and avoids errors from empty or misaligned vials. Additionally, the device’s automated handling minimizes external contamination, ensuring repeatable and accurate analytical results.

  • Yes, the Automatic Headspace Sampler is highly compatible with various gas chromatographs used in laboratories worldwide. It can be seamlessly connected to chromatographs and workstations, allowing direct data transfer and synchronized operation. The sampler reads chromatographic signals in real-time, improving workflow efficiency and ensuring accurate sample analysis.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.