Request A Quote
Gel Card Incubator LIGC-A10

Gel Card Incubator LIGC-A10

Gel Card Incubator LIGC-A10 is a blood card incubator with a capacity of 24 cards.  It features two independent incubation zones each with a capacity of 12 cards. The incubator has a timing range of 0 to 99 minutes and 59 seconds. Also, it is equipped with an audible, programmable alarm to signal the end of the incubation period. Our incubator is designed specifically for incubating gel cards, commonly used in blood typing and ID card applications.

Gel Card Incubator LIGC-A10
Request Quote
Capacity 24 Blood cards
Incubation Temperature 37℃ ± 0.1℃
Temperature Accuracy Less than 0.5°C
Temperature Uniformity Up to ± 0.5℃
Time Range 0 to 99 min 59 sec
Display Yes
Permissible Temperature 10 to 37℃
Power Consumption 250 W
Power Supply AC 220 V 50 Hz/ 110 V 60 Hz
Dimension (W×D×H) 390 × 280 × 140 mm
Package Dimension (W×D×H) 445 × 345 × 200 mm
Net Weight 6.2 kg
Gross Weight 8 kg
  • Digital display

  • Real-time monitoring

  • Timer function

  • Alarm function

  • Compact and bench-top design

Our Gel Card Incubator LIGC-A10 is used for incubating blood typing and ID gel cards at a controlled temperature. It is suitable for various gel cards from different manufacturers in clinical laboratories.

Gel Card Incubator LIGC-A10 | Time Range 0 to 99 min 59 sec | Incubation temperature: 37℃ ± 0.1℃
Gel Card Incubator LIGC-A10 | Real-time monitoring | Timer function


Models of Gel Card Incubator

Labtron Gel Card Incubator features capacity of up to 24 gel cards for testing. They are equipped with advanced microprocessor technology for accurate and stable temperature control operations. Their built-in sensors continuously monitor environmental conditions, ensuring correct thermal consistency. They are equipped with built-in timers to automate incubation, minimizing human error and improving productivity. Our Gel Card Incubator is required for serological testing methods, such as blood typing, antibody screening, and cross-matching.

Gel Card Incubator LIGC-A11

Gel Card Incubator LIGC-A11

  • Capacity : 24 Gel cards (6 column/8 column)
  • Timing Range : 1sec to 99min 59sec / ∞
  • Temperature Setting Range : 26℃ to 38℃
  • Heating Time : Up to 4 min (from 25℃ to 38℃)

Gel Card Incubator LIGC-A10 FAQ's
  • Labtron’s Gel Card Incubator LIGC-A10 is used for incubating blood typing and ID gel cards at a constant temperature of 37°C. It ensures uniform thermal conditions required for accurate serological testing in clinical labs. It supports various gel card brands and is ideal for routine blood group identification and antibody screening. Its precise temperature control makes it essential for immunohematology procedures. It helps achieve reliable test results with minimal variability. It is widely used in hospitals, diagnostic labs, and blood banks.

  • Our Gel Card Incubator LIGC-A10 features two independent zones, each capable of holding 12 gel cards, allowing up to 24 cards to be processed simultaneously. This enables labs to run different tests or sample batches at the same time. Each zone can be timed separately, offering operational flexibility. It reduces wait times and boosts throughput, especially in high-demand settings. Separate zones minimize sample handling errors. It’s highly efficient for busy clinical environments.

  • Gel Card Incubator LIGC-A10 includes a digital display, timer, real-time monitoring, and a programmable alarm. These features make it easy to operate and monitor. Users can set incubation time precisely and receive an alert when the cycle ends. The display provides clear status updates throughout the process. Its compact and ergonomic design enhances convenience. These features together support consistent and user-friendly operation.

  • Yes, our Gel Card Incubator LIGC-A10 offers highly stable and accurate temperature control with a range of 37°C ± 0.1°C. It ensures temperature accuracy of less than ±0.5°C and uniformity of ±0.5°C. These specifications meet the clinical requirements for precise and reproducible testing. Accurate incubation is essential for sensitive blood typing assays. It helps avoid false results due to inconsistent thermal conditions. The performance is dependable even during continuous use.

  • The audible programmable alarm in Gel Card Incubator LIGC-A10 alerts the user at the end of the incubation period, preventing over-incubation or delays. It enhances workflow efficiency by allowing technicians to multitask without needing to constantly monitor the device. The alarm is especially useful in busy labs to avoid missed steps. It improves test result reliability by ensuring precise incubation timing. The feature also supports lab safety by drawing attention at the right moment. This helps maintain high-quality control standards.

Post your question?

Our experts are here to help!

Gel Card Incubator:
Gel Card Incubator LIGC-A11, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.