Request A Quote
Halogen Moisture Analyzer LHMA-B11

Halogen Moisture Analyzer LHMA-B11

Halogen Moisture Analyzer LHMA-B11 50 g for precise moisture content. It features a built-in calibration system that ensures measurement. The design allows for easy sample loading. Its low-maintenance operation provides reliable performance. Our halogen moisture analyzer delivers consistent test accuracy for quality control in the food and chemical industries.

Halogen Moisture Analyzer LHMA-B11_Side View (1)
Halogen Moisture Analyzer LHMA-B11_Side View (2)
Request Quote
Capacity 50 g
Readability 1 mg
Repeatability 0.2 %
Minimum Sample Amount 0.5 g
Advised Sample Amount 3 to 10 g
Heat up time 1-99 minutes, 1 minute interval
Heating Temperature 50 to 160°C, 1°C interval
Heating Source Halogen Lamp
Heating Time 30 minutes
Ambient Temperature 10 to 30°C
Ambient Humidity ≤75 %
Pan Dimensions 80 mm
Dimensions (L × W × H) 210 × 340 × 180 mm
Packing Dimensions (L × W × H) 380 × 530 × 340 mm
Gross Weight 3 kg
Net Weight 5 kg
  • Rapid Drying System

  • Adjustable Heating Range

  • Real-Time Data Display

  • Auto Shut-Off Function

  • Durable Stainless Steel Pan

Halogen Moisture Analyzer LHMA-B11 is a laboratory device that determines the moisture content in samples using halogen heating for rapid drying. It is widely used in pharmaceutical, chemical, and agricultural industries for accurate and efficient moisture analysis.

Accessories Name

Quantity

Calibration Weight

1

Power Cord

1

Models of Halogen Moisture Analyzer

Labtron Halogen Moisture Analyzer provide humidity content measurement with sample capacity of 1mg to 210 g. They offer temperature range of 40℃ to 230℃ ensuring correct evaluation for diverse samples. Their advanced heating technology ensures quick and reliable analysis reducing the time required for consistent results. They feature user-friendly interface, simplifying operation and data interpretation with real-time data display for immediate results. Our Halogen Moisture Analyzer ensures quality by quantifying humidity in pharmaceuticals, food, agriculture, chemicals and plastics.

Halogen Moisture Analyzer LHMA-A24

Halogen Moisture Analyzer LHMA-A24

  • Capacity Range : 120 g
  • Accuracy : 0.01 g
  • Repeatability less than 2 g : 0.0005
  • Repeatability less than 1 g : 0.001
Halogen Moisture Analyzer LHMA-A22

Halogen Moisture Analyzer LHMA-A22

  • Capacity : 210g
  • Readability : 0.001g
  • Operating Temperature : 5°C to 35°C
  • Pan Size : Ø100mm
Halogen Moisture Analyzer LHMA-C11

Halogen Moisture Analyzer LHMA-C11

  • Capacity : 50 g
  • Readability : 1 mg
  • Repeatability : 0.002
  • Minimum Sample Amount : 0.5 g
Halogen Moisture Analyzer LHMA-B12
Halogen Moisture Analyzer LHMA-B12
  • Capacity : 50 g
  • Readability : 5 mg
  • Repeatability : 0.3 %
  • Minimum Sample Amount : 0.5 g
Halogen Moisture Analyzer LHMA-C15
Halogen Moisture Analyzer LHMA-C15
  • Capacity : 100 g
  • Readability : 5 mg
  • Repeatability : 0.003
  • Minimum Sample Amount : 0.5 g
Halogen Moisture Analyzer LHMA-A13

Halogen Moisture Analyzer LHMA-A13

  • Range : 1 mg to 110 g
  • Readability : 1 mg
  • Temperature range : 40 to 199°C
  • Heat source : Halogen lamp-1
Halogen Moisture Analyzer LHMA-A10

Halogen Moisture Analyzer LHMA-A10

  • Range : 10 mg to 110 g
  • Readability : 10 mg
  • Temperature range : 40 to 199°C
  • Heat source : Halogen lamp-1
Halogen Moisture Analyzer LHMA-C10

Halogen Moisture Analyzer LHMA-C10

  • Capacity : 10 g
  • Readability : 10 mg
  • Repeatability : 0.005
  • Minimum Sample Amount : 0.5 g

Halogen Moisture Analyzer LHMA-B11 FAQ's
  • Labtron Halogen Moisture Analyzer LHMA-B11 duration of a moisture analysis using the LHMA-B11 largely depends on the sample type, initial moisture content, and selected drying parameters. However, the analyzer is designed for rapid results, with most moisture tests completed in 5 to 15 minutes. Thanks to the powerful halogen heating system, it significantly reduces drying time compared to conventional ovens, which may take hours. In automatic mode, the analyzer continuously monitors the weight loss and ends the test when the rate of moisture evaporation stabilizes this eliminates the need for guesswork or constant observation. The time efficiency is highly beneficial in fast-paced environments such as quality control labs or production lines, where quick turnaround of results is critical. This also allows more samples to be tested in less time, enhancing throughput and overall laboratory productivity. For time-critical or high-volume testing environments, this feature is a significant advantage over traditional methods.

  • Labtron halogen moisture analyzer LHMA-B11, Calibration is a crucial part of ensuring the ongoing accuracy and reliability. While the device is built for stability and precision, it is recommended to perform calibration at regular intervals, depending on the usage frequency and the importance of the analysis. For labs operating under strict quality guidelines such as GLP, GMP, or ISO, calibration should be performed daily or before every critical batch test. The LHMA-B10 may include internal calibration features using built-in weights or support external calibration using certified test weights and temperature calibration kits. Temperature calibration ensures that the halogen heater provides accurate and uniform heat, which is essential for consistent moisture readings. Regular calibration helps detect drifts or inconsistencies before they impact results, minimizing errors and ensuring compliance with regulatory standards. Detailed logs of calibration activities should also be maintained for audit purposes.

  • Labtron’s halogen moisture analyzer LHMA-B11 is engineered for low-maintenance operation, but routine care enhances its lifespan and performance. After each use, the sample tray and surrounding chamber should be cleaned of any residue or spilled material using a soft brush or cloth. Regular cleaning prevents sample contamination and buildup that could affect weight readings or heating efficiency. The halogen lamp, which is central to the analyzer’s drying function, should be periodically inspected and replaced if signs of wear (e.g., dimming or flickering) are observed. The touchscreen interface should be gently wiped with a non-abrasive cloth to maintain visibility and responsiveness. It's also important to keep the unit in a stable, vibration-free environment, away from excessive humidity, dust, or chemical vapors that could interfere with its sensitive weighing mechanism. Performing occasional software checks and storing the unit with a protective cover when not in use are good practices. Always follow the manufacturer’s user manual for specific maintenance guidelines and service intervals.

  • Yes, Labtron’s halogen moisture analyzer LHMA-B11 is well-suited for heat-sensitive or volatile samples, provided it is used with appropriate settings and precautions. The analyzer features adjustable temperature controls, usually in a range from 40°C to 200°C, allowing users to tailor the drying process according to the sample’s thermal tolerance. For sensitive compounds that degrade, oxidize, or volatilize at high temperatures, users can select a lower drying temperature and use gradual heating profiles to prevent sample decomposition. Additionally, the live drying curve displayed on the screen allows users to monitor drying behavior in real-time, ensuring that volatile elements are not inadvertently driven off too quickly. However, extremely volatile or reactive substances may still require specialized handling or alternative analytical techniques. In such cases, it’s important to consult the sample’s Material Safety Data Sheet (MSDS) and conduct small-scale tests before full analysis. Proper sample preparation and test mode selection make the LHMA-B10 highly adaptable for sensitive materials.

  • Yes, Labtron halogen moisture analyzer LHMA-B11 is designed to meet common international standards for moisture analysis, making it a reliable instrument in both regulated and non-regulated settings. It supports compliance with ISO, ASTM, USP, EP, and other standards widely used in pharmaceuticals, food safety, environmental testing, and industrial applications. The device offers high measurement precision, repeatability, and traceability, all of which are crucial for meeting Good Laboratory Practices (GLP) and Good Manufacturing Practices (GMP). Its ability to export data, store test history, and integrate with quality systems also helps organizations fulfill audit trail and documentation requirements. Before implementation in a highly regulated environment, it’s advisable to verify the model’s specific certifications, calibration reports, and test method validations. The LHMA-B10’s flexibility, robust design, and data integrity features make it an excellent choice for institutions that prioritize compliance.

Post your question?

Our experts are here to help!

Halogen Moisture Analyzer:
Halogen Moisture Analyzer LHMA-A24, Halogen Moisture Analyzer LHMA-A22, Halogen Moisture Analyzer LHMA-C11, Halogen Moisture Analyzer LHMA-B12, Halogen Moisture Analyzer LHMA-C15, Halogen Moisture Analyzer LHMA-A13, Halogen Moisture Analyzer LHMA-A10, Halogen Moisture Analyzer LHMA-C10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.