| Capacity | 50 g |
| Readability | 1 mg |
| Repeatability | 0.2 % |
| Minimum Sample Amount | 0.5 g |
| Advised Sample Amount | 3 to 10 g |
| Heat up time | 1-99 minutes, 1 minute interval |
| Heating Temperature | 50 to 160°C, 1°C interval |
| Heating Source | Halogen Lamp |
| Heating Time | 30 minutes |
| Ambient Temperature | 10 to 30°C |
| Ambient Humidity | ≤75 % |
| Pan Dimensions | 80 mm |
| Dimensions (L × W × H) | 210 × 340 × 180 mm |
| Packing Dimensions (L × W × H) | 380 × 530 × 340 mm |
| Gross Weight | 3 kg |
| Net Weight | 5 kg |
Rapid Drying System
Adjustable Heating Range
Real-Time Data Display
Auto Shut-Off Function
Durable Stainless Steel Pan
Halogen Moisture Analyzer LHMA-B11 is a laboratory device that determines the moisture content in samples using halogen heating for rapid drying. It is widely used in pharmaceutical, chemical, and agricultural industries for accurate and efficient moisture analysis.
Accessories Name | Quantity |
Calibration Weight | 1 |
Power Cord | 1 |
Labtron Halogen Moisture Analyzer provide humidity content measurement with sample capacity of 1mg to 210 g. They offer temperature range of 40℃ to 230℃ ensuring correct evaluation for diverse samples. Their advanced heating technology ensures quick and reliable analysis reducing the time required for consistent results. They feature user-friendly interface, simplifying operation and data interpretation with real-time data display for immediate results. Our Halogen Moisture Analyzer ensures quality by quantifying humidity in pharmaceuticals, food, agriculture, chemicals and plastics.








Labtron Halogen Moisture Analyzer LHMA-B11 duration of a moisture analysis using the LHMA-B11 largely depends on the sample type, initial moisture content, and selected drying parameters. However, the analyzer is designed for rapid results, with most moisture tests completed in 5 to 15 minutes. Thanks to the powerful halogen heating system, it significantly reduces drying time compared to conventional ovens, which may take hours. In automatic mode, the analyzer continuously monitors the weight loss and ends the test when the rate of moisture evaporation stabilizes this eliminates the need for guesswork or constant observation. The time efficiency is highly beneficial in fast-paced environments such as quality control labs or production lines, where quick turnaround of results is critical. This also allows more samples to be tested in less time, enhancing throughput and overall laboratory productivity. For time-critical or high-volume testing environments, this feature is a significant advantage over traditional methods.
Labtron halogen moisture analyzer LHMA-B11, Calibration is a crucial part of ensuring the ongoing accuracy and reliability. While the device is built for stability and precision, it is recommended to perform calibration at regular intervals, depending on the usage frequency and the importance of the analysis. For labs operating under strict quality guidelines such as GLP, GMP, or ISO, calibration should be performed daily or before every critical batch test. The LHMA-B10 may include internal calibration features using built-in weights or support external calibration using certified test weights and temperature calibration kits. Temperature calibration ensures that the halogen heater provides accurate and uniform heat, which is essential for consistent moisture readings. Regular calibration helps detect drifts or inconsistencies before they impact results, minimizing errors and ensuring compliance with regulatory standards. Detailed logs of calibration activities should also be maintained for audit purposes.
Labtron’s halogen moisture analyzer LHMA-B11 is engineered for low-maintenance operation, but routine care enhances its lifespan and performance. After each use, the sample tray and surrounding chamber should be cleaned of any residue or spilled material using a soft brush or cloth. Regular cleaning prevents sample contamination and buildup that could affect weight readings or heating efficiency. The halogen lamp, which is central to the analyzer’s drying function, should be periodically inspected and replaced if signs of wear (e.g., dimming or flickering) are observed. The touchscreen interface should be gently wiped with a non-abrasive cloth to maintain visibility and responsiveness. It's also important to keep the unit in a stable, vibration-free environment, away from excessive humidity, dust, or chemical vapors that could interfere with its sensitive weighing mechanism. Performing occasional software checks and storing the unit with a protective cover when not in use are good practices. Always follow the manufacturer’s user manual for specific maintenance guidelines and service intervals.
Yes, Labtron’s halogen moisture analyzer LHMA-B11 is well-suited for heat-sensitive or volatile samples, provided it is used with appropriate settings and precautions. The analyzer features adjustable temperature controls, usually in a range from 40°C to 200°C, allowing users to tailor the drying process according to the sample’s thermal tolerance. For sensitive compounds that degrade, oxidize, or volatilize at high temperatures, users can select a lower drying temperature and use gradual heating profiles to prevent sample decomposition. Additionally, the live drying curve displayed on the screen allows users to monitor drying behavior in real-time, ensuring that volatile elements are not inadvertently driven off too quickly. However, extremely volatile or reactive substances may still require specialized handling or alternative analytical techniques. In such cases, it’s important to consult the sample’s Material Safety Data Sheet (MSDS) and conduct small-scale tests before full analysis. Proper sample preparation and test mode selection make the LHMA-B10 highly adaptable for sensitive materials.
Yes, Labtron halogen moisture analyzer LHMA-B11 is designed to meet common international standards for moisture analysis, making it a reliable instrument in both regulated and non-regulated settings. It supports compliance with ISO, ASTM, USP, EP, and other standards widely used in pharmaceuticals, food safety, environmental testing, and industrial applications. The device offers high measurement precision, repeatability, and traceability, all of which are crucial for meeting Good Laboratory Practices (GLP) and Good Manufacturing Practices (GMP). Its ability to export data, store test history, and integrate with quality systems also helps organizations fulfill audit trail and documentation requirements. Before implementation in a highly regulated environment, it’s advisable to verify the model’s specific certifications, calibration reports, and test method validations. The LHMA-B10’s flexibility, robust design, and data integrity features make it an excellent choice for institutions that prioritize compliance.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608