Request A Quote
Hot Air Sterilizer LHAS-A10

Hot Air Sterilizer LHAS-A10

Hot Air Sterilizer LHAS-A10 operates within a temperature range of RT+10 to 250℃. Transparent window made of tempered glass allows easy observation without disturbing inner environment. Equipped with mechanical thermostat for reliable operation, during primary temperature control failure. Features high quality stain-less steel chamber with adjustable shelves. Ideal for equipment sterilization, cosmetic tool sterilization and metal tool disinfection.

Hot Air Sterilizer_LHAS-A10_Front View
Hot Air Sterilizer_LHAS-A10_Chamber View
Request Quote
Capacity 81L
Temperature range RT+10 to 250℃
Temperature Resolution 0.1℃
Temperature Fluctuation ±1℃
Temperature Uniformity ±2.5℃%
Operating Temperature +5 to 40℃
Timer 1 to 9999min
Shelves 2/6
Power Consumption 1500W
Power Supply 220V, 50HZ
Internal Dimension 450mm × 400mm × 450mm
External Dimension 730mm × 530mm × 690mm
Net Weight 49kg
Gross Weight 60kg
  • Forced air convection 
  • Uniform temperature control
  • Microprocessor-based controller
  • Thermally insulated handle
  • LCD screen display

Our Hot Air Sterilizer LHAS-A10 is widely used in industries for moisture-sensitive material processing, pharmaceutical equipment sterilization, cosmetic tool sterilization and metal tool disinfection.

Models of Hot Air Sterilizer

Labtron Hot Air Sterilizer utilize advanced dry heat technology to achieve uniform sterilization. These are built with high-quality stainless-steel chamber to ensure corrosion resistance. They offer microprocessor or PID control systems for precise temperature regulation. They feature timer and alarm functions for safe, self-regulated operation. Our sterilizers are ideally used in microbiology labs, pharmaceutical, food and beverage industries.

Hot Air Sterilizer LHAS-A12

Hot Air Sterilizer LHAS-A12

  • Capacity : 252L
  • Temperature range : RT+10 to 250℃
  • Temperature Resolution : 0.1℃
  • Temperature Fluctuation : ±1℃
Hot Air Sterilizer LHAS-A11

Hot Air Sterilizer LHAS-A11

  • Capacity : 138L
  • Temperature range : RT+10 to 250℃
  • Temperature Resolution : 0.1℃
  • Temperature Fluctuation : ±1℃
Hot Air Sterilizer LHAS-A10 FAQ's
  • Labtron’s Hot Air Sterilizer LHAS-A10 features a durable stainless-steel chamber with a capacity of 81L. It includes 2 adjustable shelves, supporting up to 6 shelf positions for flexibility. The chamber is anti-corrosive and easy to clean, ensuring long-lasting performance. Designed for efficient sterilization of tools and equipment. Ideal for small to medium lab and industrial use. Built to support repeated high-temperature cycles.

  • Labtron’s Hot Air Sterilizer LHAS-A10 operates within a temperature range of RT+10°C to 250°C. A microprocessor-based controller ensures precise temperature regulation with ±1°C fluctuation. Forced air convection maintains uniform heat distribution with ±2.5% uniformity. Also equipped with a mechanical thermostat for backup control. These features ensure consistent and reliable sterilization. Suitable for temperature-sensitive and critical lab procedures.

  • The Hot Air Sterilizer LHAS-A10 includes a transparent tempered glass window for easy observation. This allows users to monitor contents without disturbing the internal environment. A thermally insulated handle protects users from heat during operation. Designed with user safety and convenience in mind. Ideal for labs, clinics, and sterilization rooms. Safe to operate during long sterilization cycles.

  • The Hot Air Sterilizer LHAS-A10 features an LCD screen display with real-time temperature and timing data. It supports a timer range of 1 to 9999 minutes for scheduled operation. Microprocessor control allows accurate and repeatable sterilization cycles. Quick setup and monitoring ensure user-friendly operation. These features are suitable for both skilled and routine users. Built for efficiency and ease of use.

  • Labtron’s Hot Air Sterilizer LHAS-A10 are widely used for pharmaceutical equipment sterilization, cosmetic tool disinfection, and metal tools. Also ideal for moisture-sensitive materials that cannot withstand steam sterilization. Used in medical labs, salons, research institutions, and industrial settings. Ensures safe, contamination-free sterilization using dry heat. Trusted in environments requiring high hygiene standards. Compact and efficient for versatile sterilization tasks.

  • Labtron’s Hot Air Sterilizer uses dry heat to eliminate microorganisms. It operates by circulating heated air within a sealed chamber. Temperatures typically range from 160°C to 250°C, depending on the application. The process denatures microbial proteins, ensuring sterilization of heat-resistant items. No moisture is involved, making it ideal for materials sensitive to steam. Sterilization cycles may last 30 minutes to 2 hours, based on load and temperature.

  • Labtron’s Hot Air Sterilizer are extensively used in laboratories, hospitals, and pharmaceutical industries. Ideal for sterilizing glassware, metal instruments, powders, and non-porous materials. Also used for heat-tolerant lab equipment and tools that can’t be steam-sterilized. Common in microbiology labs for petri dishes, flasks, and syringes. Often used in cosmetics, food testing, and research facilities for dry sterilization. Suited for applications requiring moisture-free sterilization conditions.

  • Labtron’s Hot air sterilization uses dry heat, while autoclaving uses moist heat (steam). Dry heat operates at higher temperatures and for longer durations. It is suitable for items sensitive to moisture or corrosion. Autoclaving is faster and more efficient for heat-stable, moisture-tolerant items. Hot air sterilizers are preferred when steam could damage materials or residues. Each method is chosen based on material compatibility and sterilization need.

  • Most Hot Air Sterilizer feature digital or mechanical temperature controls for precision. Equipped with over-temperature protection and leakage safety mechanisms. Chambers are often stainless steel, offering durability and easy cleaning. Timer and alarm systems allow safe, unattended operation. Some models include adjustable shelves, viewing windows, or data logging. These features ensure both user safety and process reliability.

  • Before loading into the Hot Air Sterilizer, it is confirmed that the items should be clean and dry. Arrange instruments evenly with gaps to allow airflow circulation. Avoid overcrowding, which may reduce temperature uniformity. Use only heat-resistant, dry-heat compatible materials (no plastics or liquids). Close the door tightly and ensure air vents are properly adjusted. Follow manufacturer instructions for optimal sterilization results.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.