Request A Quote
ATP Hygiene Monitoring System LAHMS-A10

ATP Hygiene Monitoring System LAHMS-A10

ATP Hygiene Monitoring System LAHMS-A10 features a high sensitivity with a detection limit as low as 10⁻16 moles of ATP. It uses a swab to measure ATP levels through a bioluminescent reaction and delivers results in about 10 seconds. The system has a 3.5-inch high-resolution color screen with an intuitive interface. Its powerful memory capacity enables efficient tracking and long-term hygiene monitoring. Our system evaluates surface cleanliness by detecting ATP (adenosine triphosphate), a biological marker in all living organisms.

ATP Hygiene Monitoring System LAHMS-A10
ATP Hygiene Monitoring System LAHMS-A10
ATP Hygiene Monitoring System LAHMS-A10
Request Quote
Detection Limit 10-16 moles ATP
Detection Deviation 5% or ± 5
Self-Calibration at Startup 15s or 60s
Real-Time Detection Time 10 sec per test
Reproducibility CV 8% to 20%
Correlation Coefficient R2 is greater or equal to 0.99
Memory Capacity 255 test plans, 255 user IDs, 2000 test programs, 1000 results
Communication Interface USB and Bluetooth
Running Time Continuously work for more than 8 h
Standby for more than 600 h
Permissible Temperature 5 to 40ºC
Permissible Humidity Less than 60%
Power Supply Rechargeable Battery
Dimension 189 × 70 × 36 mm
Weight 300 g
  • Low power consumption

  • USB and Bluetooth connectivity

  • Quick self-calibration

  • Pre-configured templates

  • Intuitive operation

Our ATP Hygiene Monitoring System LAHMS-A10 is used to verify surface cleanliness in food processing, healthcare, pharmaceuticals, and environmental monitoring. It helps detect contamination quickly to ensure hygiene compliance and prevent microbial risks.

Name

Quantity

Liqu Swab

400 pieces per pack

Quick Swab

400 pieces per pack




Hygiene Monitoring System Supplier

Labtron offers a wide range of Hygiene Monitoring Systems, designed for rapid and reliable assessment of surface cleanliness. All our systems offer rapid detection with high sensitivity, ensuring quick and accurate assessment of surface hygiene. These systems detect the presence of organic residues like ATP to verify the effectiveness of cleaning procedures. They feature user-friendly operation and are well-equipped with data storage and connectivity options. Our systems are used in food processing, healthcare, pharmaceuticals, and sanitation services.

ATP Hygiene Monitoring System LAHMS-A10 FAQ's
  • Labtron’s ATP Hygiene Monitoring System LAHMS-A10 is designed to rapidly assess the cleanliness of surfaces by detecting ATP (adenosine triphosphate), a molecule found in all living organisms. By identifying the presence of ATP through a bioluminescent reaction, it helps determine whether a surface has been effectively cleaned or may still harbor organic contamination. It delivers results in just 10 seconds, making it ideal for real-time hygiene verification in regulated environments.

  • Our ATP Hygiene Monitoring System LAHMS-A10 offers exceptional sensitivity, with a detection limit as low as 10?¹? moles of ATP. Its reproducibility ranges from 8% to 20% CV, and it provides a strong correlation coefficient (R² is greater than or equal to 0.99), ensuring consistent and reliable results. This level of precision is crucial in industries such as healthcare, food processing, and pharmaceuticals, where microbial contamination must be tightly controlled.

  • ATP Hygiene Monitoring System LAHMS-A10 is designed for intuitive operation with a 3.5-inch high-resolution color screen, USB and Bluetooth connectivity, and pre-configured templates that simplify the workflow. It also includes a quick self-calibration process at startup (15 or 60 seconds), ensuring measurement consistency without extensive user input. Its compact design and lightweight structure (300 g) make it easy to use in field or facility inspections.

  • Our ATP Hygiene Monitoring System LAHMS-A10 is suitable for a range of controlled environments where hygiene is critical. These include food processing plants, healthcare facilities, pharmaceutical production areas, and environmental monitoring sectors. It operates reliably within a temperature range of 5 to 40°C and at humidity levels below 60%, allowing for dependable use across various indoor settings.

  • It is equipped with robust memory capacity, the ATP Hygiene Monitoring System LAHMS-A10 can store up to 255 test plans, 255 user IDs, 2000 test programs, and 1000 individual test results. This enables long-term data tracking and user-specific monitoring. The system is ideal for facilities that need to maintain audit trails or comply with hygiene verification standards and regulations.

  • A Hygiene Monitoring System is a tool used to evaluate the cleanliness of surfaces, equipment, or environments by detecting the presence of organic residues such as ATP since it is a biomarker present in all living beings. It is especially important in regulated industries like food processing, pharmaceuticals, and healthcare, where even minor contamination can lead to health hazards, product recalls, or regulatory non-compliance.

  • Our Hygiene Monitoring System typically uses bioluminescence-based ATP detection. This involves swabbing a surface with a specialized collection swab and inserting it into a handheld luminometer. Biomarker, if present on the surface, reacts with a reagent in the device to emit light, which is measured in relative light units (RLU). The intensity of light indicates the level of contamination. This process provides results within seconds and helps users take immediate corrective actions if hygiene levels are insufficient.

  • Labtron’s Hygiene Monitoring Systems can be effectively used in any environment where hygiene is critical, including food manufacturing plants, hospitals, laboratories, pharmaceutical production areas, commercial kitchens, cleanrooms, and environmental inspection settings. Its versatility allows organizations to verify cleaning processes across surfaces, equipment, and even water samples. These systems are particularly valuable in facilities where frequent cleaning validations are required as part of regulatory compliance or internal quality assurance protocols.

  • Labtron’s Hygiene Monitoring System offers several advantages over traditional microbiological methods. It delivers immediate results (typically within 10 to 15 seconds), allowing real-time decisions about sanitation effectiveness. In contrast, microbiological cultures can take 24 to 72 hours. Hygiene monitoring systems are portable, easy to operate, and do not require lab expertise. They are ideal for routine verification, reducing downtime, and allowing for quick corrective measures, making them more efficient for daily operational use.

Post your question?

Our experts are here to help!

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.