| Temperature Range | -50 to 950℃ (-58 to 1742°F) |
| Measurement Accuracy | Greater than 0°C: ±1.5°C ; Less than 0°C: ±3°C |
| Measuring Distance Ratio | 12:1 |
| Emissivity | 0.1 to 1.0 |
| Response Time | 0.5 seconds |
| Wavelength | 5 to 14 μm |
| Repeatability | 1% or 1°C |
| Resolution | 0.1°C |
| Storage Temperature | -20 to 60°C (-14 to 140 °F) |
| Operating Temperature | 0 to 40°C (32 to 104 °F) |
| Operating Humidity | 10 to 90% |
| Display | Colour LCD Display |
| Power Supply | 9 V |
| Dimensions (L × W × D) | 250 × 200 × 200 mm |
| Weight | 0.500 Kg |
Consistent measurement accuracy
Accurate remote targeting
Wide infrared detection range
Ambient temperature compensation
Infrared Thermometer LIFT-D29 measures surface temperatures without contact by detecting emitted heat. It is commonly used for ideal for glass manufacturing, server room temperature monitoring, painting and coating curing processes, plastic molding operations, food storage inspection, and scientific experiments.
Download catalog for
Infrared Thermometer LIFT-D29 Catalog
Available Range :
Infrared Thermometer LIFT-D14 : -50 to 1050℃ (-58 to 1562°F) Infrared Thermometer LIFT-A26 : -50 to 1100℃ (-58 to 2012℉) Infrared Thermometer LIFT-A19 : -50 to 1200℃ (-58 to 2192℉) Infrared Thermometer LIFT-A27 : -50 to 1300℃ (-58 to 2372℉) Infrared Thermometer LIFT-A20 : -50 to 1400℃ (-58 to 2552℉) Infrared Thermometer LIFT-A28 : -50 to 1600℃ (-58 to 2912℉) Infrared Thermometer LIFT-D25 : -50 to 380℃ (-58 to 1742°F) Infrared Thermometer LIFT-A13 : -50 to 380℃ (-58 to 716℉) Infrared Thermometer LIFT-D23 : -50 to 390℃ (-58 to 734°F) Infrared Thermometer LIFT-D15 : -50 to 400℃ (-58 to 752°F) Infrared Thermometer LIFT-A15 : -50 to 400℃ (-58 to 752℉) Infrared Thermometer LIFT-D26 : -50 to 420℃ (-58 to 788°F) Infrared Thermometer LIFT-D10 : -50 to 550°C (-58 to 1022 F) Infrared Thermometer LIFT-D27 : -50 to 550℃ (-58 to 1022°F) Infrared Thermometer LIFT-A14 : -50 to 550℃ (-58 to 1022℉) Infrared Thermometer LIFT-D24 : -50 to 590℃ (-58 to 1094°F) Infrared Thermometer LIFT-D16 : -50 to 600℃ (-58 to 1112°F) Infrared Thermometer LIFT-A16 : -50 to 600℃ (-58 to 1112℉) Infrared Thermometer LIFT-D12 : -50 to 650℃ (-58 to 1202°F) Infrared Thermometer LIFT-D28 : -50 to 750℃ (-58 to 1382°F) Infrared Thermometer LIFT-A25 : -50 to 750℃ (-58 to 1382℉) Infrared Thermometer LIFT-D21 : -50 to 800℃ (-58 to 1472°F) Infrared Thermometer LIFT-A18 : -50 to 800℃ (-58 to 1472℉) Infrared Thermometer LIFT-D11 : -50 to 850℃ (-58 to 1562°F) Infrared Thermometer LIFT-A12 : -50 to 950°C (-58 to 1742°F) Infrared Thermometer LIFT-D22 : -50 to 950℃ (-58 to 1742°F) Infrared Thermometer LIFT-A21 : -50 to1650℃ (-58 to 3002℉) Infrared Thermometer LIFT-A11 : -50 ℃ to 380 ℃ (-58 ℉ to 716 ℉) Infrared Thermometer LIFT-A10 :| Forehead | 32 ℃ - 42.9 ℃ |
| Object | 0 ℃ - 60 ℃ |
| Room | 0 ℃ - 40 ℃ |
Labtron Infrared Thermometer features a device that freezes and displays readings, allowing users to capture and review temperature measurements. These track the highest and lowest temperatures, providing accurate monitoring over time. Their laser pointer is included to enhance accuracy by precisely targeting the measurement area. They have a low battery indicator that alerts users when the battery needs replacement, ensuring uninterrupted operation. Our infrared thermometer has a backlight function that improves readability, making it easy to use in low-light conditions.







.webp)
The Infrared Thermometer LIFT-D29 is capable of measuring temperatures as high as 950°C (1742°F). This makes it ideal for applications in foundries, metallurgy, and other high-temperature industrial environments. It also handles sub-zero temperatures down to -50°C (-58°F), offering wide usability across varied sectors. The extended range allows for non-contact monitoring of both extremely hot and cold surfaces. Its precise detection helps reduce the risk of error during critical temperature assessments. Users working with furnaces, kilns, or heated machinery will find it particularly beneficial. The wide measurement span adds flexibility for diverse testing conditions.
Yes, the Infrared Thermometer LIFT-D29 features an adjustable emissivity range from 0.10 to 1.00. This allows the user to fine-tune the device based on different surface types, whether shiny metals or matte materials. Accurate emissivity settings lead to better measurement precision, especially when switching between different textures and finishes. The preset default is 0.95, suitable for most general surfaces. However, for more specific use cases, adjusting the emissivity enhances result accuracy. This flexibility is important in industries that require precise thermal readings across varied materials. It makes the thermometer versatile for technical field work.
Our Infrared Thermometer LIFT-D29 ensures swift and reliable results. This fast reaction time allows users to take multiple readings in quick succession without delay. It is particularly useful in dynamic environments where temperature changes rapidly. The quick measurement helps in monitoring heat-sensitive processes and ensuring safety standards. Real-time thermal assessments reduce downtime and improve workflow efficiency. Users can depend on it for fast diagnostics and accurate results with minimal lag. The responsiveness also supports better decision-making in critical conditions.
Labtron’s Infrared Thermometer LIFT-D29, offering consistent performance and extended operational time. This type of battery is easy to find and replace, ensuring the device stays ready for use. The design helps minimize power interruptions during critical measurements. Along with automatic shutdown and a low battery alert, power management is optimized for fieldwork. This is ideal for technicians and inspectors who rely on battery-powered instruments. Users benefit from the convenience of long battery life and energy efficiency. The compact power solution supports portable and dependable usage.
Yes, the Infrared Thermometer LIFT-D29 supports data storage and reading functions. This feature allows users to review past readings for comparison and analysis. It is helpful in scenarios where tracking temperature over time is critical. The ability to store and recall data makes it suitable for documentation and quality control tasks. In lab, warehouse, and industrial settings, stored data allows for better monitoring and performance analysis. The functionality improves efficiency by reducing the need for repeated measurements. It also aids in troubleshooting and historical monitoring.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom