Iron Meter LIRM-A10

Iron Meter LIRM-A10

Iron Meter LIRM-A10 is mainly used to detect metal particles in oil samples extracted from cylinder friction oil. It provides a simple and easy-to-use platform that makes testing and analysis easy.  Its measurement range for particle analysis is 0 to 2500 ppm in a short testing time. The operating temperature is from 5℃ to 40 ℃, allowing flexibility in analysis conditions. Additionally, it has a testing time duration of less than 3 seconds, allowing fast individual sample testing. Our iron meters have vast applications for machine system wear monitoring, evaluation of lubricating oil, evaluation of ferromagnetic debris in the gearbox, etc.

Request Quote
Measurement Range 0 - 2500ppm
Sample Testing Method Ferromagnetic method
Operating Temperature Range 5°C - 40°C
Display Resolution 5ppm
Repeatability +/- 10ppm (0 - 1000ppm),
Sample vial Standard 5ml Test Tube
Testing Time Duration Less than 3 seconds per sample
Power Supply 24V DC power supply including UK, EU, and US power adapters.
Weight 1.1 KG
  • High accuracy

  • On-site testing for remote locations

  • Compact design

  • User-friendly operation

The Iron meter LIRM-A10 tester is mainly used to detect metal particles in oil samples extracted from cylinder friction oil. Our iron meters have vast applications for machine system wear monitoring, evaluation of lubricating oil, evaluation of ferromagnetic debris in the gearbox, etc.

Download catalog for
Iron Meter LIRM-A10 Catalog


Iron Meter Supplier

Iron meters are used to detect metal particles present in the oil samples extracted from cylinder friction oil. They have a compact and portable design that allows easy transportation. Their analysis method analyzes the sample in a very short time span of less than 2 seconds, and offers fast analysis of the samples. These iron meters have collaborating abilities with a cold corrosion testing kit to obtain a ship cylinder oil total iron measurement iron wear instrument offers accuracy. Our iron meters have vast applications for machine system wear monitoring, evaluation of lubricating oil, evaluation of ferromagnetic debris in the gearbox, etc.

Iron Meter LIRM-A10 FAQ's
  • Labtron’s Iron meter LIRM-A10 operates using a colorimetric detection method, where a reagent reacts with iron ions in the sample to produce a colored complex. The instrument measures the color intensity using a photometric sensor, which directly correlates with the iron concentration. This method enables precise quantification of dissolved or total iron in water, oil, or other fluids, making the Iron meter LIRM-A10 ideal for corrosion monitoring, water quality analysis, and lubricant contamination assessment in industrial environments.

  • The Iron meter LIRM-A10 can detect ferrous (Fe²?), ferric (Fe³?), and total iron in liquid samples. For total iron measurement, the instrument uses a digestion process to convert all iron forms into a detectable state. This flexibility makes the Iron meter LIRM-A10 suitable for various applications such as coolant testing, boiler feed water monitoring, and used oil analysis. Knowing both dissolved and particulate iron content helps determine system health, corrosion activity, and early signs of mechanical wear or contamination.

  • Labtron’s Iron meter LIRM-A10 offers a typical detection range of 0.01 to 10 mg/L (ppm), making it suitable for low to moderate iron concentrations in industrial fluids. The instrument delivers high accuracy, generally within ±5% of the measured value, and features automatic calibration routines using certified iron standards. Its sensitivity and repeatability make it a reliable tool for trend monitoring in corrosion control, water treatment, and condition-based maintenance of lubricated machinery systems.

  • The Iron meter LIRM-A10 typically requires 10–20 milliliters of liquid sample per test. Water samples may need to be filtered to remove suspended solids, while oil samples often require dilution or acid digestion to release bound iron particles. After preparation, the reagent is added to the sample, and the instrument automatically reads the iron concentration. Proper sample handling and consistent preparation are essential to achieving accurate and reproducible results across a range of fluid types.

  • Labtron’s Iron meter LIRM-A10 requires routine cleaning of the optical cell and proper storage of reagents to ensure reliable performance. Calibration should be performed using iron standard solutions, typically on a weekly or per-use basis depending on application frequency. The system’s software guides users through calibration and verification steps. Replacing expired reagents and maintaining the sensor optics helps ensure consistent accuracy, making the Iron meter a dependable instrument for regular iron level monitoring in various industrial systems.

Post your question?

Our experts are here to help!

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.