Low-Temperature Water Bath LLWB-E10 operates from -20℃ to 99℃ for flexible applications. It delivers stable performance with ±0.1℃ accuracy using PID-controlled temperature adjustment. The built-in pump supports a strong 8 to 10L/min flow rate for external circulation. The compact design features compressor-based refrigeration for efficient and quick cooling. Ideal for heating and cooling cycles in chemical, pharmaceutical, and industrial labs.

Request Quote
Volume 20L
Temperature Range -20 to 99°C
Temperature Fluctuation ±0.1°C
Pump Flow 8 to 10L/min
Working Size 400 × 320 × 160 mm
Openings Size 160 × 160 mm
Voltage 110V 60Hz / 220V 50Hz
Power 1500W
Product Dimension 500 × 430 × 900 mm
Packaging Dimension 620 × 500 × 950 mm
Net Weight 45kg
Gross Weight 58kg
  • Digital control panel display

  • Fast refrigeration cycle

  • External liquid circulation capability

  • Stable thermal performance

  • User-friendly temperature settings

  • Over-current protection system

  • Low water level alarm

Our Low-Temperature Water Bath LLWB-E10 is designed for dual heating and cooling tasks. It is ideal for applications in chemical analysis, pharmaceutical formulation, and biochemical research involving controlled thermal cycling. 

Accessory

Quantity

Heating Tube

1 pc

Motor

1 pc

Lid

1 pc

Low-Temperature Water Bath LLWB-E10 | Volume: 20L | Temperature Fluctuation: ±0.1°C
Low-Temperature Water Bath LLWB-E10 | Digital control panel display | Fast refrigeration cycle

Models of Low-Temperature Water Bath

Labtron Low-Temperature Water Bath ensure temperature control with high-performance thermostat for consistent workflow. Their energy-efficient design minimizes power consumption while maintaining uniform temperature across tank. They offer user-friendly interface with intuitive controls for easy setup and customization. Their advanced insulation reduces heat loss and enhances system efficiency during extended operations. Our Low-Temperature Water Bath is ideal for pharmaceuticals, biotechnology, research, and chemical analysis.

Low-Temperature Water Bath LLWB-C13

Low-Temperature Water Bath LLWB-C13

  • Volume : 20L
  • Temperature Range : -70°C to 100°C
  • Temperature Fluctuation : ±0.05°C
  • Temperature Resolution : 0.01°C
Low-Temperature Water Bath LLWB-B12

Low-Temperature Water Bath LLWB-B12

  • Volume : 15L
  • Temperature Range : -60°C to 100°C
  • Temperature Fluctuation : ±0.05°C
  • Temperature Resolution : 0.01°C
Low-Temperature Water Bath LLWB-D14

Low-Temperature Water Bath LLWB-D14

  • Volume : 30L
  • Temperature Range : -80°C to 100°C
  • Temperature Fluctuation : ±0.05°C
  • Temperature Resolution : 0.01°C
Low-Temperature Water Bath LLWB-D13
Low-Temperature Water Bath LLWB-D13
  • Volume : 20L
  • Temperature Range : -80°C to 100°C
  • Temperature Fluctuation : ±0.05°C
  • Temperature Resolution : 0.01°C
Low-Temperature Water Bath LLWB-C10
Low-Temperature Water Bath LLWB-C10
  • Volume : 6L
  • Temperature Range : -70°C to 100°C
  • Temperature Fluctuation : ±0.05°C
  • Temperature Resolution : 0.01°C
Low-Temperature Water Bath LLWB-A10

Low-Temperature Water Bath LLWB-A10

  • Capacity : 6L
  • Temperature Range : -50°C to 100°C
  • Temperature Stability : ±0.05°C
  • Measurement Accuracy : 0.01°C
Low-Temperature Water Bath LLWB-B11

Low-Temperature Water Bath LLWB-B11

  • Volume : 10L
  • Temperature Range : -60°C to 100°C
  • Temperature Fluctuation : ±0.05°C
  • Temperature Resolution : 0.01°C
Low-Temperature Water Bath LLWB-B14

Low-Temperature Water Bath LLWB-B14

  • Volume : 30L
  • Temperature Range : -60°C to 100°C
  • Temperature Fluctuation : ±0.05°C
  • Temperature Resolution : 0.01°C
Low-Temperature Water Bath LLWB-E10 FAQ's
  • The Low-Temperature Water Bath requires different liquid media based on operating temperatures. Alcohol is used below 5°C, water between 5°C and 80°C, and antifreeze solution from 0°C to -20°C. Selecting the appropriate medium ensures effective thermal transfer. This also prevents damage to the heating components during operation.

  • Labtron’s Low-Temperature Water Bath uses PID automatic control for accurate thermal stability. It responds quickly to temperature changes, minimizing fluctuations during long experimental runs. This ensures consistent performance, even during extended heating or cooling cycles. The system is ideal for temperature-sensitive applications.

  • Labtron’s Low-Temperature Water Bath must be filled with liquid at least 100 mm above the heating element before powering on, to prevent damage and overheating. Labtron advises ensuring the unit is properly grounded to avoid electrical hazards. Maintain a 300 mm clearance on all sides for adequate ventilation and safe operation. Avoid operating the circulation pump without liquid to prevent internal damage. Always switch off and unplug the Low-Temperature Water Bath after use for safe handling and maintenance.

  • The Low-Temperature Water Bath should be cleaned after each use to maintain its performance. It is recommended to use a soft cloth or tissue paper to wipe the display screen and exterior surfaces to avoid scratching. Harsh objects or abrasive materials should never be used, as they could damage the delicate components. After cleaning, ensure the power is off before performing maintenance or cleaning tasks. Regular cleaning will help prolong the lifespan of the unit and ensure reliable operation.

  • Our Low-Temperature Water Bath is equipped with an alarm system for operational errors, which will be indicated by the display showing "----" and the buzzer sounding continuously. In this case, it is essential to check the temperature sensor and wiring for any faults. If the issue persists, the system may require technical support or servicing to resolve the error. Regular maintenance and careful handling can help prevent such operational errors and keep the bath functioning properly.

  • Our Low-Temperature Water Bath is designed to support external circulation through a built-in circulating pump. This feature allows users to transfer temperature-controlled liquid to external equipment or samples, providing versatile thermal management. The bath can be integrated with other laboratory systems that require consistent temperature regulation. This functionality is essential for experiments that need precise thermal conditions beyond the bath itself.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.