Microwave Digestion System LMWD-C10 features a pressure display accuracy of ±0.1MPa, ensuring precise monitoring and safe control of internal reaction during sample digestion. The digestion vessels are constructed from premium materials, preventing chemical resistance and providing thermal stability. The system has integrated optical fiber sensors for accurate temperature measurement. Our microwave digestion system emits a uniform microwave field, ensuring all samples placed in the chamber are heated evenly and rapidly.

Microwave Digestion System LMWD-C10_Front View
Microwave Digestion System LMWD-C10_ Top View
Microwave Digestion System LMWD-C10_ Top View
Request Quote
Microwave cavity 65L, 316 L stainless steel and outer multi-layer corrosion resistant PFA Teflon spraying.
Microwave Source 2450 MHz, dual magnetron high-energy emission.
Temperature Control Real time detection, temperature and curve, display inside dissolving tank: maximum temperature ≥300°C.
Pressure Control G-pressure monitors, overpressure adjustment, automatic alarm
Pressure Measurement Piezoelectric pressure sensor
External digestion tank pressure: ≥ 20MPa
Internal digestion tank pressure: ≥ 4MPa
Volume: ≥100 ml
Pressure Display Accuracy ±0.1MPa
Temperature Measurement Optical fiber sensors
Temperature Control Accuracy ± 0.1℃
Full Tank Temperature 0 to 350℃,
Control Accuracy ± 0.1°C at 0.1°C / Min
External Interface USB, RS-232
Sample Reaction Outer Tank PEEK material explosion-proof external tank.
Furnace Exhaust System High-power axial flow fan, turbulent high-efficiency air cooling, 15 min from 200℃ to 60℃ in 15 minutes.
Working Environment 0 to 40 °C, 15 to 80% RH
Batch Volume 32 Hard Drive, 2G Memory
Magnetic Stirring 50 sets
Inner Tank Material TFM
Outer Tank Material PEEK
Rotor Frame High strength turntable integrated frame
Reaction Tank Volume 100 ml
Name of Reaction Tank 6 tanks with high pressure resistance
Batch Amount 6
Maximum Pressure 16 M Pa
Maximum Temperature 310° C
Display Screen Large 7-inch touch LCD screen.
Software System The ARM chip comes with a ZG operating system.
Installation Power of Machine 3200W
Power Supply 220-240 VAC 50/60Hz, 15A
Dimension 580mm × 680mm × 720mm
Net Weight 65 kg
  • Rapid Sample Preparation

  • Low Blank Values

  • Automatic Calibration Mode

  • Remote Monitoring System

  • Precise Temperature Control

Microwave Digestion System LMWD-C10 is a laboratory device that uses microwave energy to rapidly and efficiently break down samples in acids. It plays a key role in food, textiles, plastics, geology, and metallurgy for rapid sample decomposition

Models of Microwave Digestion System

Labtron Microwave Digestion System offers a wide temperature and pressure range for diverse digestion requirements. They include multiple safety protection functionalities, ensuring operator well-being. Maintains data integrity with reliable data logging and storage capabilities. Their intuitive operation with a user-friendly interface allows easy programming. Our microwave digestion system accesses pre-programmed digestion methods to specific sample types and research requirements.

Microwave Digestion System LMWD-A11

Microwave Digestion System LMWD-A11

  • Cavity : 48 L Resonant Cavity
  • Teflon Coating : 10
  • Power Output : 1600 W
  • Digestion Method : 50 preinstalled methods, programming 100 method
Microwave Digestion System LMWD-B16

Microwave Digestion System LMWD-B16

  • Vessel Quantity : 12
  • Temperature Monitoring System : Contactless IR Sensor, scan monitoring for each vessel
  • Temperature Controlling Range : 50 to 400℃
  • Display Accuracy : ± 0.1℃
Microwave Digestion System LMWD-A20

Microwave Digestion System LMWD-A20

  • Vessel Quantity : 6
  • Temperature Monitoring System : Contactless IR Sensor, scan monitoring for each vessel
  • Temperature Controlling Range : 50 to 400℃
  • Display Accuracy : ± 0.1℃
Microwave Digestion System LMWD-B14
Microwave Digestion System LMWD-B14
  • Sample quantity : 40 per batch
  • Chamber volume : 50 ml
  • Rotation mode : 360° continuous rotation
  • Microwave power : 0 to 3000 W adjustable
Microwave Digestion System LMWD-B13
Microwave Digestion System LMWD-B13
  • Sample quantity : 18 per batch
  • Chamber volume : 100 ml
  • Rotation mode : 360° continuous rotation
  • Microwave power : 0 to 3000 W adjustable
Microwave Digestion System LMWD-C11

Microwave Digestion System LMWD-C11

  • Microwave cavity : 65L, 316 L stainless steel and outer multi-layer corrosion resistant PFA Teflon spraying.
  • Microwave Source : 2450 MHz, dual magnetron high-energy emission.
  • Temperature Control : Real time detection, temperature and curve, display inside dissolving tank: maximum temperature ≥300°C.
  • Pressure Control : G-pressure monitors, overpressure adjustment, automatic alarm
Microwave Digestion System LMWD-A14

Microwave Digestion System LMWD-A14

  • Microwave Source : 2450MHz, Dual magnetron, high-energy emission
  • Microwave Cavity : 65L, 316L stainless steel with multi-layer PFA Teflon coating
  • Temperature Control : Dual ZG system, real-time temperature detection, and curve display for all tanks
  • Pressure Control : G-pressure monitoring automatic overpressure adjustment and alarm (range: 0 to 2000psig)
Microwave Digestion System LMWD-B10

Microwave Digestion System LMWD-B10

  • Vessel Quantity : 8
  • Temperature Monitoring System : Contactless IR Sensor, scan monitoring for each vessel
  • Temperature Controlling Range : 50 to 400℃
  • Display Accuracy : ± 0.1℃
Microwave Digestion System LMWD-C10 FAQ's
  • Labtron microwave digestion systems LMWD-C10 employ individual vessel pressure sensors—such as piezoelectric or ideal gas detectors—to monitor each sample’s internal pressure in real time. This enables precise adjustment of microwave power to maintain the target pressure curve per vessel. As a result, digestion uniformity is significantly improved across batches, reducing variability in temperature and reaction rates. This leads to consistent digestion outcomes and higher recovery rates for trace elements. Such control is crucial when processing mixed-matrix sample types, ensuring each vessel follows identical reaction conditions.

  • Labtron supplies premium model of microwave digestion system LMWD-C10. Advanced systems integrate multi-layer safety features including robust resonant cavities, triple-interlock door seals, and auto-shutdown protocols when pressures exceed limits. In addition, auto-venting systems safely release pressure when necessary, preventing vessel rupture. Metal mesh observation windows combined with reinforced doors protect users from microwave exposure, while high-strength vessel materials and exhaust fans further shield against chemical release. These redundant safeguards ensure safe operation even under extreme temperature–pressure conditions.

  • Many systems come preloaded with application-specific cookbooks—optimized protocols detailing acid type, sample mass, ramp/hold profiles, vessel volume, and pressure limits. This feature simplifies method setup, accelerates validation, and ensures reproducibility across different operators and labs. Users can also customize and save protocols for niche matrices, improving throughput and reducing the risk of user error. By streamlining method selection, cookbooks boost efficiency in regulated environments, such as pharma or environmental labs

  • Labtron supplies advanced models of microwave digestion system LMWD-C10. After digestion, built-in cooling systems—including internal/external high-speed fans or exhaust turbo blowers—rapidly lower vessel temperature and pressure. This minimises turnaround time by enabling quicker sample retrieval and preparation for analysis. It also avoids thermal shock, which can degrade vessel integrity over multiple cycles. As a result, vessel lifespan is extended, lowering operational costs while maintaining consistent digestion conditions batch after batch

  • Labtron’s Microwave digestion system LMWD-C10 dramatically reduces prep time (minutes instead of hours or days) by achieving high temperatures and pressures in sealed vessels. It also uses fewer reagents, generates lower blanks, and facilitates better recovery of volatile elements compared to hot-plate or dry-ashing methods. Choosing the right system involves evaluating max microwave power, sensor type (e.g., fiber-optic for temperature), vessel capacity, method support, and maintenance availability.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.