| Microwave cavity | 65L, 316 L stainless steel and outer multi-layer corrosion resistant PFA Teflon spraying. |
| Microwave Source | 2450 MHz, dual magnetron high-energy emission. |
| Temperature Control | Real time detection, temperature and curve, display inside dissolving tank: maximum temperature ≥300°C. |
| Pressure Control | G-pressure monitors, overpressure adjustment, automatic alarm |
| Pressure Measurement | Piezoelectric pressure sensor External digestion tank pressure: ≥ 20MPa Internal digestion tank pressure: ≥ 4MPa Volume: ≥100 ml |
| Pressure Display Accuracy | ±0.1MPa |
| Temperature Measurement | Optical fiber sensors |
| Temperature Control Accuracy | ± 0.1℃ |
| Full Tank Temperature | 0 to 350℃, |
| Control Accuracy | ± 0.1°C at 0.1°C / Min |
| External Interface | USB, RS-232 |
| Sample Reaction Outer Tank | PEEK material explosion-proof external tank. |
| Furnace Exhaust System | High-power axial flow fan, turbulent high-efficiency air cooling, 15 min from 200℃ to 60℃ in 15 minutes. |
| Working Environment | 0 to 40 °C, 15 to 80% RH |
| Batch Volume | 32 Hard Drive, 2G Memory |
| Magnetic Stirring | 50 sets |
| Inner Tank Material | TFM |
| Outer Tank Material | PEEK |
| Rotor Frame | High strength turntable integrated frame |
| Reaction Tank Volume | 100 ml |
| Name of Reaction Tank | 6 tanks with high pressure resistance |
| Batch Amount | 6 |
| Maximum Pressure | 16 M Pa |
| Maximum Temperature | 310° C |
| Display Screen | Large 7-inch touch LCD screen. |
| Software System | The ARM chip comes with a ZG operating system. |
| Installation Power of Machine | 3200W |
| Power Supply | 220-240 VAC 50/60Hz, 15A |
| Dimension | 580mm × 680mm × 720mm |
| Net Weight | 65 kg |
Rapid Sample Preparation
Low Blank Values
Automatic Calibration Mode
Remote Monitoring System
Precise Temperature Control
Microwave Digestion System LMWD-C10 is a laboratory device that uses microwave energy to rapidly and efficiently break down samples in acids. It plays a key role in food, textiles, plastics, geology, and metallurgy for rapid sample decomposition
Download catalog for
Microwave Digestion System LMWD-C10 Catalog
Available Range :
Microwave Digestion System LMWD-B12 : 316L stainless steel cavity with corrosion-proof coating Microwave Digestion System LMWD-C10 : 65L, 316 L stainless steel and outer multi-layer corrosion resistant PFA Teflon spraying. Microwave Digestion System LMWD-C12 : 65L, 316L stainless steel and outer multi-layer corrosion resistant PFA Teflon spraying. Microwave Digestion System LMWD-A14 : 65L, 316L stainless steel with multi-layer PFA Teflon coating Microwave Digestion System LMWD-A11 : SS316 with 10 layer Teflon Microwave Digestion System LMWD-A10 : SS316 with 8 layer TeflonLabtron Microwave Digestion System offers a wide temperature and pressure range for diverse digestion requirements. They include multiple safety protection functionalities, ensuring operator well-being. Maintains data integrity with reliable data logging and storage capabilities. Their intuitive operation with a user-friendly interface allows easy programming. Our microwave digestion system accesses pre-programmed digestion methods to specific sample types and research requirements.








Labtron microwave digestion systems LMWD-C10 employ individual vessel pressure sensors—such as piezoelectric or ideal gas detectors—to monitor each sample’s internal pressure in real time. This enables precise adjustment of microwave power to maintain the target pressure curve per vessel. As a result, digestion uniformity is significantly improved across batches, reducing variability in temperature and reaction rates. This leads to consistent digestion outcomes and higher recovery rates for trace elements. Such control is crucial when processing mixed-matrix sample types, ensuring each vessel follows identical reaction conditions.
Labtron supplies premium model of microwave digestion system LMWD-C10. Advanced systems integrate multi-layer safety features including robust resonant cavities, triple-interlock door seals, and auto-shutdown protocols when pressures exceed limits. In addition, auto-venting systems safely release pressure when necessary, preventing vessel rupture. Metal mesh observation windows combined with reinforced doors protect users from microwave exposure, while high-strength vessel materials and exhaust fans further shield against chemical release. These redundant safeguards ensure safe operation even under extreme temperature–pressure conditions.
Many systems come preloaded with application-specific cookbooks—optimized protocols detailing acid type, sample mass, ramp/hold profiles, vessel volume, and pressure limits. This feature simplifies method setup, accelerates validation, and ensures reproducibility across different operators and labs. Users can also customize and save protocols for niche matrices, improving throughput and reducing the risk of user error. By streamlining method selection, cookbooks boost efficiency in regulated environments, such as pharma or environmental labs
Labtron supplies advanced models of microwave digestion system LMWD-C10. After digestion, built-in cooling systems—including internal/external high-speed fans or exhaust turbo blowers—rapidly lower vessel temperature and pressure. This minimises turnaround time by enabling quicker sample retrieval and preparation for analysis. It also avoids thermal shock, which can degrade vessel integrity over multiple cycles. As a result, vessel lifespan is extended, lowering operational costs while maintaining consistent digestion conditions batch after batch
Labtron’s Microwave digestion system LMWD-C10 dramatically reduces prep time (minutes instead of hours or days) by achieving high temperatures and pressures in sealed vessels. It also uses fewer reagents, generates lower blanks, and facilitates better recovery of volatile elements compared to hot-plate or dry-ashing methods. Choosing the right system involves evaluating max microwave power, sensor type (e.g., fiber-optic for temperature), vessel capacity, method support, and maintenance availability.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608