| Temperature Range of Gradient Platen | -10° C to +90° C |
| No. of points of Gradient Platen | 16 |
| Interval Distance of Gradient | 20 mm |
| Test Channels | 6 pcs (width is 22 mm) |
| Gradient Platen Size | 447mm × 210 mm |
| Tester Size (L × W × H) | 600 mm ×450 mm × 300 mm |
| Cooling water tank Size (L × W × H) | 560 mm × 240 mm × 200 mm |
| Dry Air Generator (L × W × H) | 555 mm × 255 mm × 525 mm |
| Power Supply | 220V / 50 Hz AC wide voltage |
| Power Consumption | 750 W |
| Net Weight | 26 kg (Excludes Cooling water tank and Dry Air Generator) |
| Gross weight | 68 kg |
Wide Temperature Range
Removable Illuminated Scale
Multi-Channel Testing
Built-in Safety Monitoring
Programmable Measurement Points
Minimum Film Forming Temperature Tester LMFFT-A10 uses a metal plate with a controlled temperature gradient to find the lowest temperature at which film is formed. It is applied in paint, coatings, adhesives, latex, polymer dispersion and industrial manufacturing.
Dry Air Generator - 1 Pc
Download catalog for
Minimum Film Forming Temperature Tester LMFFT-A10 Catalog
Labtron Minimum Film Forming Temperature Tester determines the white point of polymer dispersions, emulsions, and adhesives. These feature a copper platen with an electronically controlled temperature gradient. Their steady stream of dry air ensures stable drying conditions across the gradient and minimizes humidity. They include multiple digital sensors for real-time temperature mapping. Our minimum film-forming temperature tester is equipped with an integrated water-break protection system for continuous monitoring of the cooling water supply, making it ideal for laboratory operations.
Labtron supplies premium models of minimum film forming temperature tester LMFFT-A10. Calibration of the minimum film forming temperature tester relies on embedded precision sensors adjusted against reference standards The tester often includes built-in calibration routines and provides certificates. Calibration checks both the cold and warm ends of the gradient for linearity. Alarms monitor cooling flow and temperature drift during operation Periodic validation using known standards confirms accuracy. Documentation ensures audit trails and supports regulatory compliance.
Labtron’s minimum film forming temperature tester LMFFT-A10 enables formulators to tailor coalescing agents, plasticizers, or solid content to meet performance thresholds. Knowing the MFFT helps prevent film defects like cracking or whitening. It supports QC by monitoring batch-to-batch variation. It guides shipping and storage decisions by defining minimum storage temperatures. In adhesives, it identifies cure conditions alongside film formation data. Reliable MFFT data enhances product consistency, reducing costly formulation errors and improving user satisfaction.
Users of a minimum film forming temperature tester LMFFT-A10 should ensure clean, dry air or nitrogen supply and maintain coolant flow. The hinged cover protects operators from aerosolized chemicals. Platen, lid, and applicators must be cleaned after each test to avoid residue buildup. Inspect seals and cooling lines regularly for wear or leaks. Confirm alarm functionality for water-flow and temperature anomalies. Replace worn parts promptly and log all maintenance actions. This safeguards operator safety and keeps test results accurate and repeatable.
To confirm the gradient accuracy of a minimum film forming temperature tester LMFFT-A10, users should run a gradient verification routine before testing. This involves preheating and pre-cooling the platen per instrument instructions. Visual or electronic checks—using embedded sensors—ensure the temperature increases evenly from one end to the other. The user then examines gradient readings across all zones or programs. Many testers have built-in guides or diagnostics; some offer external printouts for traceability. Regular gradient verification ensures that recorded minimum film forming temperatures remain accurate and reproducible, which is essential for controlling coating formulation quality.
. Reliable operation of a minimum film forming temperature tester LMFFT-A10 depends on environmental and operational controls. The workspace should be draft-free to prevent airflow disruptions, and temperature and humidity should be kept stable. Use carrier films—like polyester or foil with glycerin—to protect the platen and avoid contamination. Always allow the platen to reach equilibrium before applying samples. Ensure dry air or nitrogen flow is consistent and unaffected by ambient changes. These precautions remove external variation and improve the repeatability of minimum film forming temperature results.
Labtron’s minimum film forming temperature tester uses a metal platen with a controlled temperature gradient, cooling one end and heating the other. A thin wet film is applied across this gradient, while steady airflow ensures uniform drying. As the solvent evaporates, the film transitions from opaque to clear at a specific point. That change is visually detected through a hinged cover. A cursor or touchscreen marks the precise spot where film continuity begins. The tester then displays the temperature at that point, representing the minimum film forming temperature. This method gives formulators crucial insight into the lowest temperature at which their coatings form a coherent film.
Labtron’s minimum film forming temperature tester follows standards like ASTM D2354 and ISO 2115, specifying gradient length, airflow, and film thickness. These protocols define sample prep, drawdown techniques, and temperature program parameters. Standards also recommend protective films—polyester or foil with glycerin-to shield the platen from contamination. Compliance ensures consistent test results across laboratories. Traceable calibration records demonstrate validity. Following these standards ensures testing is accepted for quality assurance or regulatory use, reinforcing the reliability of MFFT data.
Labtron’s minimum film forming temperature tester uses a nickel-plated copper platen for smooth thermal gradients. Multiple embedded sensors continuously monitor the gradient’s uniformity. Uneven airflow is prevented by a sintered-metal distribution block, with dry air or nitrogen flow. It also includes water-cooling circuits and alarms to prevent equipment failures. A hinged transparent cover keeps conditions steady while allowing observation. Touchscreen controls guide temperature program selection and display gradient data.
Labtron’s minimum film forming temperature tester is ideal for water-based coatings, latex paints, polymer emulsions, adhesives, and epoxy systems. These formulations depend on coalescing agents that influence film formation at low temperatures. Testing reveals the lowest temperature where film integrity is achieved, guiding formulation tweaks. It ensures the final product withstands application in various climates. Adhesives benefit too, as the tester identifies a minimum cure temperature alongside film formation data This tool supports R&D, QC, and batch consistency across industries.
Labtron’s minimum film forming temperature tester is powered on and a temperature gradient program selected. The instrument equilibrates to stabilize the thermal gradient. A controlled wet film is drawn across the platen using a cube applicator. Airflow is activated from cold to warm end. The test continues until the film’s opacity shifts to clarity along the gradient path. The operator moves the cursor or marks the touch interface at that position. The tester then reads the minimum film forming temperature. Results may be printed or saved for traceability.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608