| Temperature | 20℃ to 24℃ |
| Ambient Temperature | 10℃ to 32℃ |
| Cooling Method | Forced air cooling |
| Noise | 53 db |
| Temperature Controller | Microprocessor |
| Sensor | NTC |
| Refrigerant | R134a |
| Power Failure Backup | 72 H |
| Drawer Quantity | 10 layers |
| Platelet Bag Quantity | 20 |
| Oscillation Frequency | 60±5 e/min |
| Oscillation Amplitude | 50±10 mm |
| Shipping | 0.61 CBM |
| Current | 1.5 A |
| Power | 4,400 W |
| Power Consumption | 280 W |
| Power Supply | 220V 50Hz |
| Internal Dimension (W×D×H) | 432 × 462 × 728 mm |
| External Dimension (W×D×H) | 520 × 640 × 1305 mm |
| Packaging Dimensions (W×D×H) | 590 × 710 × 1450 mm |
| Net Weight | 85 kg |
| Gross Weight | 108.5 kg |
Anti-vibration agitation mechanism
Clear temperature display
Accurate sensor monitoring
Built-in safety features
Visual alarm indicators
Platelet Incubator LPTI-A13 is used to store blood platelets under controlled temperature and agitation conditions. It is widely applied in hospitals, blood banks, laboratories, research institutes, and universities.
Download catalog for
Platelet Incubator LPTI-A13 Catalog
Labtron Platelet Incubator feature an integrated agitator that maintains optimal storage environment at constant temperature of 22 °C. They offer parameter settings for temperature stability and use eco-friendly coolant. Their insulated chamber comes in multiple sizes to preserve many platelet bags. These are equipped with automatic safety features for reliable operation. Our high-performance Platelet Incubator are suitable for medical facilities, blood banks and research purposes.



The Platelet Incubator LPTI-A13 is specifically designed to provide a stable and controlled environment for storing platelets at the required temperature range of 20? to 24?. It ensures platelet viability through regulated cooling and gentle agitation that prevent clumping or degradation. This makes it essential in hospitals, blood banks, and laboratories where safe storage of blood components is critical. The device also supports large-scale storage needs with its multi-drawer design. By preserving platelet quality, it directly contributes to safe transfusion practices in clinical settings.
The Platelet Incubator LPTI-A13 is designed with 10 shelves, which provide ample space for organized platelet storage. These shelves are optimized to ensure that platelet bags are evenly distributed, allowing for consistent exposure to controlled temperature and agitation. With this layout, laboratory staff can maximize storage capacity while maintaining proper airflow and agitation across all units. The design minimizes the risk of overcrowding and ensures accessibility during loading and unloading. This structured arrangement makes the Platelet Incubator LPTI-A13 highly efficient for medium to high-demand storage settings.
The Platelet Incubator LPTI-A13 has a total storage capacity of 20 platelet bags, each with a 450 ml volume, per run. This capacity is well-suited for hospitals, blood centers, and transfusion services that require medium to large-scale storage solutions. By accommodating multiple platelet bags in a single cycle, the incubator reduces operational workload and optimizes available resources. The system is engineered to maintain consistent environmental conditions across all stored units, regardless of bag position. With its efficient use of space and reliable operation, the Platelet Incubator LPTI-A13 supports high-demand clinical workflows.
The Platelet Incubator LPTI-A13 operates with a microprocessor-based controller and an NTC sensor to maintain a precise temperature range of 20? to 24?. This range is internationally recognized as the optimal storage condition for platelets, ensuring their safety and functionality for transfusion. The controller ensures that even minor fluctuations are detected and corrected automatically, preserving consistent conditions throughout the storage chamber. By maintaining this narrow and critical range, the incubator protects platelets from deterioration or loss of function. The precision and reliability of the Platelet Incubator LPTI-A13 make it compliant with stringent clinical and laboratory standards.
The Platelet Incubator LPTI-A13 is designed with advanced safety mechanisms to ensure both equipment reliability and platelet integrity. It is equipped with an anti-vibration agitation system that prevents platelet clumping, thereby safeguarding the quality of stored units. The incubator also features visual alarm indicators that alert users in case of temperature deviations or mechanical issues, ensuring timely intervention. These safety features are critical in clinical settings where platelet quality directly impacts patient care. By combining stability, monitoring, and preventive safeguards, the Platelet Incubator LPTI-A13 delivers secure and dependable performance.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom