Labtron Semi-automatic Biochemistry Analyzer that works with combination of automated process and manual interventions. They are integrated with temperature control for optimal reaction condition testing. Their high-quality reagents improve reliability of test result significantly. They feature automatic calibration and maintenance reminders for consistent performance. Our Semi-automatic Biochemistry Analyzer is ideal for blood banks, clinical diagnostics and for environmental testing.
Measurement Principle: Colorimetric
Analytical Methods: End point, Fixed time, Kinetic, Absorbance, Factor
Programmable Parameters: > 200
Photometer Type: Filter
Absorbency Range: -0.3 to 3.0 abs
Resolution: 0.001 abs (display), 0.0001 abs (inner calculation)
Temperature Accuracy: ± 0.1°C
Wavelength: 340 nm, 405 nm, 510 nm, 546 nm, 578 nm, 620 nm + 2 free positions
Measuring System: Measuring Range: 0 to 3.0 ODMethod: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non LinearPhotometric linearity: ±2% (0 to 3.000 OD)Photometric accuracy: ±1% (0 to 3.000 OD)Carry over: ≤1%
Photometric System: Light source: 6 V, 10 W halogen lamp; standby functionFilters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request)Wavelength Accuracy: ±2 nm
Thermostatic Control: Temperature: 25˚C, 30˚C, 37˚CPrecision: ±0.1˚C
Drift:
Measuring System: Measuring Range: 0 to 3.0 ODMethod: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non LinearPhotometric linearity: ±2% (0 to 3.000 OD)Photometric accuracy: ±1% (0 to 3.000 OD)Carry over: ≤1%
Photometric System: Light source: 6 V, 10 W halogen lamp; standby functionFilters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request)Wavelength Accuracy: ±2 nm
Thermostatic Control: Temperature: 25˚C, 30˚C, 37˚CPrecision: ±0.1˚C
Drift:
Test Mode: Kinetic, End-point, Fixed-time, Turbidimetry , Absorbance
Wavelengths: 7 Wavelength: 340, 405, 492,510, 546,578,630 nm
Wavelength Precision: ±2 nm, width ≤ 10nm
Absorbance Range: 0 to 4.500 Abs
Detecting Wavelengths: 450, 492, 510, 546, 578, 630nm
Test Capacity: ≥70 test items
Analytical Modes: End-point, Absorbance
Display: 240 × 64 LCD
Display: 7-inch color LCD, touch screen
Test Modes: Kinetic, End point, Two point, Absorbance
Compatibility: Flow cell and cuvette test modes
Wavelengths: 7 standard filters: 340, 405, 492, 510, 546, 578, 630 nm + 1 free position
Display: 7-inch color LCD touchscreen
Test Modes: Kinetic, Endpoint, Two-point, Absorbance
Compatibility: Flow cell & cuvette test modes
Wavelengths: 7 standard filters (340, 405, 492, 510, 546, 578, 630 nm) + 1 free position