Semi-automatic Biochemistry Analyzer

Labtron Semi-automatic Biochemistry Analyzer that works with combination of automated process and manual interventions. They are integrated with temperature control for optimal reaction condition testing. Their high-quality reagents improve reliability of test result significantly. They feature automatic calibration and maintenance reminders for consistent performance. Our Semi-automatic Biochemistry Analyzer is ideal for blood banks, clinical diagnostics and for environmental testing.

Filter

Clear All

Biochemistry Analyzer

Measuring System

Photometric System

Thermostatic Control

Drift

Semi-automatic Biochemistry Analyzer LSBA-A10

Semi-automatic Biochemistry Analyzer LSBA-A10

Absorbance Range: 0 to 3.0 Abs

Aspiration Volume: 100 to 5000 µl

Wavelengths: 340 nm, 380 nm, 405 nm, 505 nm, 546 nm, 578 nm, 620 nm and 1 free position

Principle: Colorimetery, turbimetry

Semi-automatic Biochemistry Analyzer LSBA-A11

Semi-automatic Biochemistry Analyzer LSBA-A11

Absorbency Range: -0.3 to 3.0 abs

Resolution: 0.001 abs (display), 0.0001 abs (inner calculation)

Temperature Accuracy: ± 0.1°C

Wavelength: 340 nm, 405 nm, 510 nm, 546 nm, 578 nm, 620 nm + 2 free positions

Semi-automatic Bio-chemistry Analyzer LSBA-A20

Semi-automatic Bio-chemistry Analyzer LSBA-A20

Measuring System: Measuring Range: 0 to 3.0 OD Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non Linear Photometric linearity: ±2% (0 to 3.000 OD) Photometric accuracy: ±1% (0 to 3.000 OD) Carry over: ≤1%

Photometric System: Light source: 6 V, 10 W halogen lamp; standby function Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request) Wavelength Accuracy: ±2 nm

Thermostatic Control: Temperature: 25˚C, 30˚C, 37˚C Precision: ±0.1˚C

Drift:

Semi-automatic Bio-chemistry Analyzer LSBA-A21
Semi-automatic Bio-chemistry Analyzer LSBA-A21

Measuring System: Measuring Range: 0 to 3.0 OD Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non Linear Photometric linearity: ±2% (0 to 3.000 OD) Photometric accuracy: ±1% (0 to 3.000 OD) Carry over: ≤1%

Photometric System: Light source: 6 V, 10 W halogen lamp; standby function Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request) Wavelength Accuracy: ±2 nm

Thermostatic Control: Temperature: 25˚C, 30˚C, 37˚C Precision: ±0.1˚C

Drift:

Semi-automatic Bio-chemistry Analyzer LSBA-A30
Semi-automatic Bio-chemistry Analyzer LSBA-A30

Test Mode: Kinetic, Endpoint, Two-point

Wavelengths: 7wavelength: 340, 405, 492,510, 546,578,630 nm

Wavelength Precision: ±2 nm, width ≤ 10nm

Absorbance Range: 0 to 4.500 Abs


Semi-automatic Biochemistry Analyzer :
Semi-automatic Biochemistry Analyzer LSBA-A10, Semi-automatic Biochemistry Analyzer LSBA-A11, Semi-automatic Bio-chemistry Analyzer LSBA-A20, Semi-automatic Bio-chemistry Analyzer LSBA-A21, Semi-automatic Bio-chemistry Analyzer LSBA-A30, and more.

Quick Links : About Us, Contact Us, User Manuals, Career, Terms of Use, Policies, Sitemap, Gallery.

Need a Product

send details for best price quotation

Click
For

Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.