| Temperature Setting Range | 0 °C to 100 °C |
| Temperature Control Range | RT +5 ℃ to 100 ℃ |
| Shaking Speed Range | 200 to 1800 rpm |
| Temperature Accuracy | Up to ±0.3 ℃ at 37 ℃ |
| Temperature Uniformity | Up to ±0.3 ℃ at 37 ℃ |
| Orbit | 3 mm |
| Heating Time | Up to 12 min (from 25 ℃ to 100 ℃) |
| Timing Range | 1 min to 99 h 59 min/ ∞ |
| Display Accuracy | 0.1 ℃ |
| Power Requirements | AC 220 V or AC 100 V/ 50 to 60 Hz, 150 W |
| Dimensions | 260 × 195 × 150 mm |
| Net Weight | 7.0 Kg |
Thermo-Shaker Incubator LTSI-B11 is widely used in molecular biology, biochemistry, and clinical laboratories for applications requiring precise temperature control and uniform shaking. It is ideal for enzyme reactions, DNA/RNA extraction, cell lysis, immunoassays, sample thawing, and incubation processes.
| Blocks | Description |
| Block 01 | 96 × 0.2 mL ; 200 to 1800 rpm |
| Block 02 | 54 × 0.5 mL ; 200 to 1800 rpm |
| Block 03 | 35 × 1.5 mL ; 200 to 1800 rpm |
| Block 04 | 35 × 2.0 mL ; 200 to 1800 rpm |
| Block 05 | 15 × 0.5 mL + 20 × 1.5 mL ; 200 to 1800 rpm |
| Block 06 | 96 × 0.2 mL (ELISA plate) ; 200 to 1800 rpm |
| Block 07 | 24 × 5 mL ; 200 to 1000 rpm |
| Block 08 | 15 × 10 mL ; 200 to 1000 rpm |
| Block 09 | 12 × 15 mL ; 200 to 1000 rpm |
| Block 10 | 6 × 50 mL (round-shaped bottom) ; 200 to 800 rpm |
| Block 11 | 6 × 50 mL (cone-shaped bottom) ; 200 to 800 rpm |
Download catalog for
Thermo-Shaker Incubator LTSI-B11 Catalog
Labtron Thermo Shaker Incubator microprocessor-controlled incubator ensures precise temperature regulation for reliable performance. These features are programmable, proficient shaking, and temperature control, allowing users to customize settings for various applications. Their built-in temperature calibration function ensures accuracy and consistency in experimental conditions. They have multiple security functions for enhanced safety and protection. Our thermo shaker incubator supports various blocks that are convenient to replace, making it adaptable to different sample types and research needs.

.webp)
.webp)

.webp)



The Thermo-Shaker Incubator LTSI-B11 is designed with a compact and space-saving footprint, making it ideal for laboratories with limited bench space. Its lightweight structure allows for easy relocation or integration into various lab setups. The incubator accommodates interchangeable blocks that support different tube sizes, enhancing versatility for multiple protocols. Quiet operation from its brushless DC motor ensures minimal disruption in shared lab environments. Altogether, these features make it a user-friendly and adaptable instrument for routine and advanced experimental workflows.
Our Thermo-Shaker Incubator LTSI-B11 is engineered with user safety in mind, conforming to CE safety standards that ensure it meets essential regulatory guidelines. It includes built-in internal over-temperature protection that automatically prevents the system from overheating during long or high-temperature runs. This safety mechanism not only protects the device but also ensures the integrity of sensitive biological samples. Additionally, the thermal control system is highly accurate, reducing the chance of deviation or equipment failure. These protections make it a reliable and safe choice for continuous use in professional laboratory settings.
Labtron’s Thermo-Shaker Incubator LTSI-B11 is built for long-term, demanding laboratory use with high-quality materials and precision engineering. It features a brushless DC motor, which not only runs quietly but also requires no routine maintenance, significantly increasing its operational lifespan. The internal components are designed to withstand repeated thermal cycles and mechanical stress. Additionally, the sturdy construction and stable base reduce vibration and wear during high-speed shaking.
The Thermo-Shaker Incubator LTSI-B11 is equipped with a bright, easy-to-read LCD display that shows real-time values for temperature, speed, and time. This allows users to monitor and adjust experiment conditions precisely throughout the process. The digital control system provides high accuracy, with temperature control up to ±0.3°C and speed control ranging from 200 to 1800 rpm. Users can view both the set and actual parameters simultaneously, reducing the risk of errors. The interface is intuitive, supporting quick setup even for complex, multi-step protocols.
Our Thermo-Shaker Incubator LTSI-B11 supports a wide timing range from as short as 1 minute to as long as 99 hours and 59 minutes, giving users full flexibility over experiment duration. For experiments that require indefinite operation, it also offers a continuous mode, allowing uninterrupted shaking and heating. This makes it suitable for both short reactions and long incubation processes such as hybridization or protein denaturation. It is also equipped with automatic start and resume functions, which are particularly useful for multi-cycle or overnight protocols. These features ensure that extended experiments can be carried out reliably and efficiently without manual intervention.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608