Full-automatic IR Hole Transmittance Tester- LTRP-D10 offers a wavelength range of 400 to 1000 nm and accuracy of 1 nm. It is a fully automatic tester that uses a robotic arm to handle sample positioning and testing seamlessly. The advanced CCD camera vision accurately locates the test holes in the glass and adjusts for positioning offset. It ensures enhanced production efficiency and reduces manual labour by integrating robotics with intelligent software. Our Tester is widely used in industries where high-precision hole testing is required, such as automotive glass, display panels, and optical components

Request Quote
Wavelength Range 400 to 1000 nm
Wavelength Accuracy 1 nm
Detector Full-automatic IR Hole Transmittance Detectors
Transmittance Accuracy Better than 0.5% (based on standard film)
Spot Diameter 0.3 mm
Light Source Halogen tungsten light source
Sample Test Platform loading/ unloading robot
Positioning System Visual Included
Positioning Accuracy Better than 0.08 mm
Test Capacity 1000 to 1200 pieces per hour
Sample Sorting Good and bad areas
Operating System Windows 7 to Windows 10
Display Resolution 0.01%
Power Supply 220 V, 50 Hz
  • CCD image recognition system
  • Automatic sample sorting
  • High accuracy alignment 
  • Compact design

Our Full-automatic IR Hole Transmittance Tester- LTRP-D10 is widely used in industries where high-precision hole testing is required, such as automotive glass, display panels, and optical components.

Full-automatic IR Hole Transmittance Tester- LTRP-D10 | Wavelength Range 400 to 1000 nm | Wavelength Accuracy 1 nm | Spot Diameter 0.3 mm
Full-automatic IR Hole Transmittance Tester- LTRP-D10 | CCD image recognition system | Automatic sample sorting | High accuracy alignment  | Compact design

Models of Transmittance Tester

Labtron offers a variety of Transmittance Testers with advanced spectral measurement options for fast full-spectrum transmittance analysis. They are compatible with professional measurement standards, allowing integration into regulated environments. Their automated workflows and software-controlled operations ensure efficient and repeatable testing processes. They are user-friendly, with intuitive features and customizable settings that suit diverse testing requirements. Our Testers are widely used in spectral transmittance analysis, optical component testing, and material characterization.

Transmittance Tester LTRP-E10

Transmittance Tester LTRP-E10

  • Wavelength Range : 250 to 800 nm (customizable)
  • Transmittance Measurement Range : 0 to 100%
  • Measurable Parameters : Wavelength transmittance, average transmittance, transmittance spectrum curve, transmittance change curve over time, etc
  • Measurement Wavelength Interval : 1 nm
Sunglasses Transmittance Tester LTRP-F11

Sunglasses Transmittance Tester LTRP-F11

  • Optical Wavelength : 280 to 980 nm (customizable)
  • Transmittance (Light Transmittance) Range : 0 to 100%
  • Spectral Resolution : 1 nm/5 nm
  • Wavelength Accuracy : ± 0.3 nm
Sunglasses Transmittance Tester LTRP-F12

Sunglasses Transmittance Tester LTRP-F12

  • Optical Wavelength : 360 to 1700 nm (customizable)
  • Transmittance (Light Transmittance) Range : 0 to 100%
  • Spectral Resolution : 5 nm
  • Wavelength Accuracy : ± 0.3 nm
Full-screen Plastic Transmittance Tester LTRP-B10
Full-screen Plastic Transmittance Tester LTRP-B10
  • Test Speed : Fast
  • Testing Time : Up to 1 second
  • Detection : Multi-point detection
  • Scanning Type : Full-screen scanning
Semi-automatic Light Transmittance Tester LTRP-C10
Semi-automatic Light Transmittance Tester LTRP-C10
  • Wavelength Range : 380 to 1000 nm (customizable)
  • Transmittance Range : 0 to 100%
  • Test Light Path : Vertical irradiation
  • Spectral Resolution : 1 nm
Transmittance Tester LTRP-E12

Transmittance Tester LTRP-E12

  • Wavelength Range : 900 to 1700 nm (customizable)
  • Transmittance Measurement Range : 0 to 100%
  • Measurable Parameters : Wavelength transmittance, average transmittance, transmittance spectrum curve, transmittance change curve over time, material spectrum component analysis, etc.
  • Measurement Wavelength Interval : 1 nm
Transmittance Tester LTRP-A10

Transmittance Tester LTRP-A10

  • Wavelength Range : 60 to 1000 nm
  • Transmittance Measurement Range : 0 to 100% transmittance
  • Detector Type : 2048-array photodetector
  • Spot Size : Φ 0.1 to 5mm (real-time adjustable)
Sunglasses Transmittance Tester LTRP-F10

Sunglasses Transmittance Tester LTRP-F10

  • Optical Wavelength : 360 to 780 nm (customizable)
  • Transmittance (Light Transmittance) Range : 0 to 100%
  • Spectral Resolution : 1 nm/5 nm
  • Wavelength Accuracy : ± 0.3 nm

Transmittance Tester:
Transmittance Tester LTRP-E10, Sunglasses Transmittance Tester LTRP-F11, Sunglasses Transmittance Tester LTRP-F12, Full-screen Plastic Transmittance Tester LTRP-B10, Semi-automatic Light Transmittance Tester LTRP-C10, Transmittance Tester LTRP-E12, Transmittance Tester LTRP-A10, Sunglasses Transmittance Tester LTRP-F10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.