| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ± 0.3 nm |
| Wavelength Repeatability | 0.2 nm |
| Photometric Range | 0 - 200 % T, (-0.3) to (-3.0) A, 0 - 9999 C |
| Photometric Accuracy | ± 0.3 % T |
| Photometric Repeatability | 0.2 % T |
| Detector | Silicon Photodiode |
| Light Source | Deuterium & Tungsten Halogen Lamp |
| Stray Light | ≤ 0.05 % T at 220 nm, 360 nm |
| Stability | 0.002 A / h at 500 nm |
| Data Output Port | USB |
| Power Requirement | AC 220 V / 50 Hz, 110 V / 60 Hz. |
| Noise | ± 0.001 A |
| Optical System | Single Beam (1200 lines / mm grating) |
| Baseline Flatness | ± 0.001 A |
| Printer Port | Parallel Port |
| Packing Size | 860 x 660 x 465 mm |
| Packing Weight | 35 kg |
Single Beam UV-Visible Spectrophotometer is ideal for quality control, general research, pharmaceuticals, biochemical and clinical laboratory applications
Download catalog for
Single Beam UV-Visible Spectrophotometer LUS-A11 Catalog
Available Range :
Single Beam UV-Vis Spectrophotometer LUS-C24 : 190 to 1000 nm Single Beam UV-Vis Spectrophotometer LUS-A12 : 190 to 1000nm Single Beam UV-Visible Spectrophotometer LUS-A47 : 190 to 1020 nm Single Beam UV-Visible Spectrophotometer LUS-A52 : 190 to 1100 nm Single Beam UV-Visible Spectrophotometer LUS-A10 : 190 ~ 1100 nm Single Beam UV-Visible Spectrophotometer LUS-A50 : 190nm to 1100 nm Single Beam UV-Vis Spectrophotometer LUS-C31 : 195 to 1020 nm Single Beam UV-Visible Spectrophotometer LUS-C10 : 200 to 1000 nm Single Beam UV-Vis Spectrophotometer LUS-A46 : 320 to 1020 nm Single Beam UV-Visible Spectrophotometer LUS-E10 : 320 to 1100 nm Single Beam UV-Visible Spectrophotometer LUS-C22 : 340 to 1050 nm Single Beam UV-Vis Spectrophotometer LUS-C28 : 350 to 1020 nmLabtron single beam UV-visible spectrophotometers offer a broad range of wavelengths and many choices for spectral bandwidth. They provide quantitative analysis and photometric measurement with user-friendly interfaces. They come with USB connections and a large colorful LCD display. They are flexible since they have several light sources installed. Our single beam spectrophotometers offer high performance, reliability, and accuracy with auto wavelength adjustment and robust construction.








Labtron supplies premium Single Beam UV-Visible Spectrophotometer LUS-F11. Stray light-unwanted wavelengths passing through the sample—inevitably distorts readings above 2?AU, compressing absorbance values and skewing photometric linearity. To detect it, use cutoff solutions (e.g., KCl, NaI, NaNO?) at their non-transmitting wavelengths and look for a non-zero transmittance. High-quality holographic gratings and meticulously clean internal optics help suppress stray light. Regular checks using USP or Ph.Eur. procedures, plus maintaining beam-path seals, are crucial to maintaining full dynamic range. Proper stray-light control expands reliable measurements to higher absorbance levels, ensuring data accuracy and regulatory compliance.
Labtron supplies Single Beam UV-Visible Spectrophotometer LUS-F11 with advanced features. Noise or artifacts around 320–360?nm often arise because the instrument toggles between UV (deuterium) and visible (tungsten) lamps during scans. Transient misalignment or imperfect timing introduces ghost peaks. Mitigation requires precise optical alignment, clean lamp compartments, and software settings that delay data capture during lamp switch. Regular recalibration and lamp maintenance can reduce crossover noise. This improves spectral continuity and ensures accurate absorbance values across the UV–Vis boundary.
. Labtron supplies Single Beam UV-Visible Spectrophotometer LUS-F11 with advanced features. Photometric accuracy-consistency between measured absorbance and certified standards—is vital for quantitative work. Perform linearity tests with potassium dichromate standards and compare against reference absorbances at key wavelengths. Stray-light, detector saturation, or lamp deterioration can disrupt linearity; instrument response should be linear across the working range. Regularly monitor baseline noise and linearity, updating calibration.
Labtron supplies premium Single Beam UV-Visible Spectrophotometer LUS-F11. Even in stray-light-controlled instruments, non-linearity may persist at high analyte concentrations due to molecular interactions that alter extinction coefficients or refractive indices, and absorption flattening in suspensions. To counter this, dilute samples to <1?AU or use shorter path-length cuvettes, ensuring compliance with Beer–Lambert conditions. For turbid solutions, pre-treat via filtration or centrifugation. Such steps realign calibration curves and minimize systematic error in concentration determination.