| Spectral Bandwidth | 4nm (optional 2nm) |
| Wavelength Range | 320 to 1100 nm |
| Optical System | Single beam path, holographic diffraction grating |
| Wavelength Accuracy | ± 0.8 nm |
| Wavelength Repeatability | 0.2 nm or less |
| Wavelength Setting | Automatic Wavelength Setting |
| Wavelength Resolution | 0.1 nm |
| Luminosity Range | 0 to 200% T, -0.3 to 3A, 0 to 9999 C, 0 to 9999 F |
| Photometric Accuracy | ±0.002A (0 to 0.5A), ±0.004A (0.5 to1A), ±0.3%T (0 to100%T) |
| Photometric Repeatability | ≤ 0.001A (0 to 0.5A), ≤0.002A (0.5 to 1A), ≤0.2%T (0 to 100%T) |
| Stray Light | ≤0.1%T (220/360nm) |
| Baseline Drift | ≤0.002A/ h (500nm,0A) |
| Noise | ± 0.2%T (0%T line) ±0.4%T (100%T line) ±0.001A (500nm) |
| Baseline Flatness | ±0.003A |
| Scan Speed | Three adjustable speeds: high, medium and low |
| Detector | Imported silicon photodiode |
| Light Source | Imported long-life tungsten and deuterium lamps |
| Display | 3-inch 128× 64 dot matrix LCD display |
| Keyboard | Tap film keys |
| Data Interface | USB Port |
| Printout | Microprinter, PC (Optional) |
| Power Supply | AC 902 to50V, 50/60Hz |
| Overall Dimensions | 430 ×320 ×195mm |
| Weight | 10 kg |
Wide Wavelength Range
Standard Curve Display
Silicon Photodiode Sensors
Dual Lamp Sources
Adjustable Scan Speed
Single Beam UV-Visible Spectrophotometer LUS-F12 passes monochromatic light through a sample to determine chemical characteristics. It is applied in biochemical analysis, environmental monitoring and pharmaceutical industries in quality control.
Download catalog for
Single Beam UV-Visible Spectrophotometer LUS-F12 Catalog
Available Range :
Single Beam UV-Visible Spectrophotometer LUS-E13 : 0.1, 0.2, 0.5, 1, 2, 4 and 5 nm Single Beam UV-Visible Spectrophotometer LUS-A40 : 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm Single Beam UV-Visible Spectrophotometer LUS-A22 : 0.5 nm, 1 nm, 2 nm, 4 nm adjustable Single Beam UV-Vis Spectrophotometer LUS-A57 : 0.5, 1, 2, 4 and 5 nm Single Beam UV-Vis Spectrophotometer LUS-C16 : 0.5, 1, 2, 4, and 5 nm Single Beam UV-Visible Spectrophotometer LUS-A52 : 0.5/1/2/4/5 nm Single Beam UV-Visible Spectrophotometer LUS-A51 : 1 nm Single Beam UV-Visible Spectrophotometer LUS-A11 : 1.8 nm Single Beam UV-Visible Spectrophotometer LUS-A50 : 2 nm Single Beam UV-Visible Spectrophotometer LUS-A30 : 4 nm Single Beam UV-Visible Spectrophotometer LUS-C10 : 4.0 nm Single Beam UV-Visible Spectrophotometer LUS-F10 : 4nm Single Beam UV-Visible Spectrophotometer LUS-F11 : 4nm (optional 2nm) Single-Beam UV-Vis Spectrophotometer, LUS-C29 : 5 nm Single Beam UV-Vis Spectrophotometer LUS-C28 : 6 nmLabtron single beam UV-visible spectrophotometers offer a broad range of wavelengths and many choices for spectral bandwidth. They provide quantitative analysis and photometric measurement with user-friendly interfaces. They come with USB connections and a large colorful LCD display. They are flexible since they have several light sources installed. Our single beam spectrophotometers offer high performance, reliability, and accuracy with auto wavelength adjustment and robust construction.








Labtron’s Single Beam UV-Visible Spectrophotometer LUS F12 Single Beam UV-Visible Spectrophotometer minimizes stray light—unwanted wavelengths that can distort measurements at absorbance over ~2?AU—by using high-grade holographic gratings and tight optical seals, ensuring more accurate results in high-concentration assays. Its stray light performance is validated using cutoff filters like sodium nitrite or potassium chloride, and should meet or exceed pharmacopeial standards for dynamic range. Proper external checks and maintenance ensure this capability remains intact over its service life.
Labtron’s Single Beam UV-Visible Spectrophotometer LUS-F12 incorporates automated wavelength calibration using certified standards like mercury or holmium filters, allowing users to self-verify and adjust peak positioning within ±0.1?nm accuracy. Its high-resolution holographic diffraction grating further ensures crisp spectral resolution so closely spaced peaks remain identifiable. Routine performance checks help catch minimal drift early, maintaining consistent analytical precision for critical quantitative applications.
Labtron’s Single Beam UV-Visible Spectrophotometer LUS-F12 may occasionally display ghost peaks due to internal reflections or diffraction from mirrors, gratings, or particles within the optical path. To combat this, clean and inspect all optics, ensure the monochromator slits are free from debris, and verify that internal surfaces remain well-aligned. Regular stray-light tests using cutoff filters can expose specific sources of unwanted signals, enabling precise corrective action.
Labtron supplies advanced Single Beam UV-Visible Spectrophotometer LUS-F12, deviations from linear absorbance arise when sample absorbance exceeds ~1?AU due to stray light, saturation, or chemical interactions like aggregation or refractive index shifts. To maintain Beer Lambert compliance, dilute samples, use shorter pathlength cuvettes, filter turbid solutions, and validate linearity with calibration curves. These strategies preserve quantitation integrity across concentration ranges.
Labtron’s Single Beam UV-Visible Spectrophotometer LUS-F12 transitions between deuterium and tungsten lamps around 320–360?nm; this switch can introduce artifacts if not synchronized well. To reduce crossover noise, the system delays data acquisition during lamp transitions, employs precise lamp alignment routines, and allows users to adjust the switch threshold in software. Periodic maintenance ensures smooth lamp toggling and continuity of spectra across the UV–Vis boundary.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom