Request A Quote
Single Beam UV-Visible Spectrophotometer LUS-F12

Single Beam UV-Visible Spectrophotometer LUS-F12

Single Beam UV-Visible Spectrophotometer LUS-F12 features a wavelength resolution of 0.1 nm for analyzing complex samples or subtle spectral shifts with high precision. The spectrophotometer has tungsten and deuterium lamps, ensuring complete spectral coverage. It includes holographic diffraction grating for uniform spectral efficiency across the wavelength range. Our single beam UV-visible spectrophotometer offers three adjustable scanning speeds to balance scan duration and data quality.

Request Quote
Spectral Bandwidth 4nm (optional 2nm)
Wavelength Range 320 to 1100 nm
Optical System Single beam path, holographic diffraction grating
Wavelength Accuracy ± 0.8 nm
Wavelength Repeatability 0.2 nm or less
Wavelength Setting Automatic Wavelength Setting
Wavelength Resolution 0.1 nm
Luminosity Range 0 to 200% T, -0.3 to 3A, 0 to 9999 C, 0 to 9999 F
Photometric Accuracy ±0.002A (0 to 0.5A), ±0.004A (0.5 to1A), ±0.3%T (0 to100%T)
Photometric Repeatability ≤ 0.001A (0 to 0.5A), ≤0.002A (0.5 to 1A), ≤0.2%T (0 to 100%T)
Stray Light ≤0.1%T (220/360nm)
Baseline Drift ≤0.002A/ h (500nm,0A)
Noise ± 0.2%T (0%T line)
±0.4%T (100%T line)
±0.001A (500nm)
Baseline Flatness ±0.003A
Scan Speed Three adjustable speeds: high, medium and low
Detector Imported silicon photodiode
Light Source Imported long-life tungsten and deuterium lamps
Display 3-inch 128× 64 dot matrix LCD display
Keyboard Tap film keys
Data Interface USB Port
Printout Microprinter, PC (Optional)
Power Supply AC 902 to50V, 50/60Hz
Overall Dimensions 430 ×320 ×195mm
Weight 10 kg
  • Wide Wavelength Range

  • Standard Curve Display

  • Silicon Photodiode Sensors

  • Dual Lamp Sources

  • Adjustable Scan Speed

Single Beam UV-Visible Spectrophotometer LUS-F12 passes monochromatic light through a sample to determine chemical characteristics. It is applied in biochemical analysis, environmental monitoring and pharmaceutical industries in quality control.

Models of Single Beam UV-Visible Spectrophotometer

Labtron single beam UV-visible spectrophotometers offer a broad range of wavelengths and many choices for spectral bandwidth. They provide quantitative analysis and photometric measurement with user-friendly interfaces. They come with USB connections and a large colorful LCD display. They are flexible since they have several light sources installed. Our single beam spectrophotometers offer high performance, reliability, and accuracy with auto wavelength adjustment and robust construction.

Single Beam UV-Vis Spectrophotometer LUS-C18

Single Beam UV-Vis Spectrophotometer LUS-C18

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 2 nm
  • Wavelength Setting : Automatic
  • Optical System : Single Beam, Grating 1200 lines/ mm
Single Beam UV-Visible Spectrophotometer LUS-A10

Single Beam UV-Visible Spectrophotometer LUS-A10

  • Wavelength Range : 190 ~ 1100 nm
  • Spectral Bandwidth : 1 nm
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : 0.2 nm
Single Beam UV-Vis Spectrophotometer LUS-C31

Single Beam UV-Vis Spectrophotometer LUS-C31

  • Wavelength Range : 195 to 1020 nm
  • Spectral Bandwidth : 5 nm
  • Wavelength Setting : Manual
  • Optical System : Single Beam, Grating 1200 lines/ mm
Single Beam UV-Vis Spectrophotometer LUS-C24
Single Beam UV-Vis Spectrophotometer LUS-C24
  • Wavelength Range : 190 to 1000 nm
  • Spectral Bandwidth : 4 nm
  • Wavelength Setting : Automatic
  • Optical System : Single Beam, Grating 1200 lines/ mm
Single Beam UV-Visible Spectrophotometer LUS-C11
Single Beam UV-Visible Spectrophotometer LUS-C11
  • Wavelength Range : 200 to 1000 nm
  • Spectral Bandwidth : 2 nm
  • Optical System : Single-beam, self-quasi optical path
  • Wavelength Tolerance : ±2 nm
Single Beam UV-Vis Spectrophotometer LUS-C23

Single Beam UV-Vis Spectrophotometer LUS-C23

  • Wavelength Range : 190 to 1000 nm
  • Spectral Bandwidth : 2 nm
  • Wavelength Setting : Automatic
  • Optical System : Single Beam, Grating 1200 lines/ mm
Single Beam UV-Visible Spectrophotometer LUS-A11

Single Beam UV-Visible Spectrophotometer LUS-A11

  • Wavelength Range : 190 ~ 1100 nm
  • Spectral Bandwidth : 1.8 nm
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : 0.2 nm
Single Beam UV-Visible Spectrophotometer LUS-C27

Single Beam UV-Visible Spectrophotometer LUS-C27

  • Wavelength Range : 190 to 1020 nm
  • Spectral Bandwidth : 2 nm
  • Wavelength Setting : Manual
  • Optical System : Single Beam, Grating 1200 lines/ mm
Single Beam UV-Visible Spectrophotometer LUS-F12 FAQ's
  • Labtron’s Single Beam UV-Visible Spectrophotometer LUS F12 Single Beam UV-Visible Spectrophotometer minimizes stray light—unwanted wavelengths that can distort measurements at absorbance over ~2?AU—by using high-grade holographic gratings and tight optical seals, ensuring more accurate results in high-concentration assays. Its stray light performance is validated using cutoff filters like sodium nitrite or potassium chloride, and should meet or exceed pharmacopeial standards for dynamic range. Proper external checks and maintenance ensure this capability remains intact over its service life.

  • Labtron’s Single Beam UV-Visible Spectrophotometer LUS-F12 incorporates automated wavelength calibration using certified standards like mercury or holmium filters, allowing users to self-verify and adjust peak positioning within ±0.1?nm accuracy. Its high-resolution holographic diffraction grating further ensures crisp spectral resolution so closely spaced peaks remain identifiable. Routine performance checks help catch minimal drift early, maintaining consistent analytical precision for critical quantitative applications.

  • Labtron’s Single Beam UV-Visible Spectrophotometer LUS-F12 may occasionally display ghost peaks due to internal reflections or diffraction from mirrors, gratings, or particles within the optical path. To combat this, clean and inspect all optics, ensure the monochromator slits are free from debris, and verify that internal surfaces remain well-aligned. Regular stray-light tests using cutoff filters can expose specific sources of unwanted signals, enabling precise corrective action.

  • Labtron supplies advanced Single Beam UV-Visible Spectrophotometer LUS-F12, deviations from linear absorbance arise when sample absorbance exceeds ~1?AU due to stray light, saturation, or chemical interactions like aggregation or refractive index shifts. To maintain Beer Lambert compliance, dilute samples, use shorter pathlength cuvettes, filter turbid solutions, and validate linearity with calibration curves. These strategies preserve quantitation integrity across concentration ranges.

  • Labtron’s Single Beam UV-Visible Spectrophotometer LUS-F12 transitions between deuterium and tungsten lamps around 320–360?nm; this switch can introduce artifacts if not synchronized well. To reduce crossover noise, the system delays data acquisition during lamp transitions, employs precise lamp alignment routines, and allows users to adjust the switch threshold in software. Periodic maintenance ensures smooth lamp toggling and continuity of spectra across the UV–Vis boundary.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.