info@labtron.com +44 2080 043608
Benchtop Dissolved oxygen meter LBDO-A10

Benchtop Dissolved oxygen meter LBDO-A10

Benchtop Dissolved oxygen meter LBDO-A10 is equipped with polarographic sensor to measure the dissolved oxygen content. The manual salinity & barometric pressure compensation helps in accurate measurement of dissolved oxygen. The system menu of dissolved oxygen meter can set 6 parameters which includes the number of calibration points, temperature units etc.

Request Quote
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Calibration points 1 - 2 points
Sensor type Polarographic DO probe
Temperature compensation range 0 to 40 °C, 32 to 104 °F
Barometric pressure correction 60.0 to 112.5 kPa, 450 to 850 mmHg
Salinity correction 0 - 35 g / L
% of saturation of oxygen range 0.0 to 200.0 %
% of saturation of oxygen accuracy ± 10 % F.S.
% of saturation of oxygen resolution 0.001
System menu Allows setting of 6 parameters
Data hold function Manual or automatic endpoint detection
Power off Manual or automatic (180 minutes)
Reset function Yes
Display Backlit LCD (135 × 75 mm)
Connector 6 pin mini plug
Power DC 9 V, use of SC adapter, AC 220 V / 50 Hz
Dimension (L × W × H) 210 × 205 × 75 mm
Weight 1.5 kg
  • Equipped with polarographic sensor
  • Equipped with large backlit LCD display
  • 1-2 points calibration using air saturated water & zero oxygen solution
  • Manual salinity & barometric pressure compensation for better measurement of dissolved oxygen
  • System menu allows setting the 6 optional parameters
  • Automatic temperature compensation for accurate measured value over the entire range
  • Auto hold function freezes stable, final readings for better viewing and recording
  • Reset function automatically resumes all the settings to default mode
  • Help message as an operational guide for quick beginning to the dissolved oxygen meter

Benchtop dissolved oxygen meter has applications in water & waste water management industry, environmental monitoring, surface ground water, research & development, education to detect content of dissolved oxygen.

Dissolved oxygen probe
Dissolved oxygen Electrolyte solution
Membrane cap
DC 9 V power adapter

Polarographic sensor
30 mL electrolyte solution per bottle
Membrane cap

Compare Models

Model Dissolved oxygen range Dissolved oxygen accuracy Resolution Calibration points Sensor type Temperature compensation range Barometric pressure correction Salinity correction % of saturation of oxygen range % of saturation of oxygen accuracy % of saturation of oxygen resolution System menu Data hold function Power off Reset function Memory Display Connector Stability conditions Calibration due Power Dimension (L × W × H) Weight
LBDO-A10 0.0 to 20.0 mg / L (or ppm) ± 0.5 mg / L 0.1 mg / L 1 - 2 points Polarographic DO probe 0 to 40 °C, 32 to 104 °F 60.0 to 112.5 kPa, 450 to 850 mmHg 0 - 35 g / L 0.0 to 200.0 % ± 10 % F.S. 0.001 Allows setting of 6 parameters Manual or automatic endpoint detection Manual or automatic (180 minutes) Yes - Backlit LCD (135 × 75 mm) 6 pin mini plug - - DC 9 V, use of SC adapter, AC 220 V / 50 Hz 210 × 205 × 75 mm 1.5 kg
LBDO-A11 0.0 to 20.0 mg / L (or ppm) ± 0.2 mg / L 0.01 mg / L 1 - 2 points Polarographic DO probe 0 to 50 °C, 32 to 122 °F 60.0 to 112.5 kPa, 450 to 850 mmHg 0 - 50 g / L 0.0 to 200.0 % ± 2.0 % F.S. 0.1, 1 % Allows setting of 9 parameters Manual or automatic endpoint detection Manual or automatic (10, 20, 30 minutes) Yes Stores up to 50 data sets Backlit LCD (130 × 110 mm) 6 pin mini plug Low or high 0 to 31 days DC 5 V, use of AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608