Request A Quote
Carbon Residue Tester LRCT-B11

Carbon Residue Tester LRCT-B11

Carbon Residue Tester LRCT-B11 is designed to measure the amount of carbon residue left after the combustion of petroleum products. This reliable unit is made up of stainless steel, resistant to heat and corrosion for long-term usage. It features a digital temperature control system for accurate and consistent high-temperature testing. Our Carbon residue tester offers precision and durability, making it an ideal choice for laboratories and industries specializing in fuel and lubricant quality testing.

Request Quote
Bath Type Four Holes with a Furnace
Heating Type Electric Resistance Furnace
Temperature Controlling Range 0 to 520℃
Temperature Controlling Accuracy ±5℃
Ambient Temperature 35℃
Relative Humidity ≤85%
Power Consumption ≤2000 W
Power Supply 220 V ± 10%, 50 Hz
Dimension 730 × 510 × 470 mm
  • Automated Testing
  • Higher Test Efficiency
  • Four Bath Holes
  • High-Temperature Operation
  • ASTM D189 Compliance

Carbon Residue Tester is used in laboratories and refineries to measure carbon residue in fuels and lubricants, ensuring product quality, compliance and performance in petroleum applications.

Carbon Residue Tester LRCT-B11 | Temperature Controlling Range: 0 to 520℃ | Ambient Temperature: 35℃
Carbon Residue Tester LRCT-B11 | Automated Testing | Higher Test Efficiency

Models of Carbon Residue

Labtron Carbon Residue is equipped with a digital PID temperature controller and operates in electric heating mode, ensuring precise temperature regulation and energy efficiency. These furnaces adopt a detachable receiver, allowing for easy maintenance and handling. Their system monitors the gas flow rate, ensuring optimal performance and enhanced safety. They have a two-stage pressure stabilization system and maintain consistent pressure levels for reliable operation. Our carbon residue has high-temperature operation and delivers stable and consistent performance even under extreme conditions.

Carbon Residue Tester (Ramsbottom) LRCT-B20

Carbon Residue Tester (Ramsbottom) LRCT-B20

  • Coking furnace : Metal furnace
  • Heating mode : Electric heating
  • Test unit : 5 units
  • Temperature range : Ambient to 550°C
Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

  • Porcelain crucible : 30 ml
  • Inner iron crucible : 75 ml
  • Outer iron crucible : 190 ml
  • Bore Diameter : Ø130 ± 5 mm
Micro Carbon Residue Tester LRCT-C10

Micro Carbon Residue Tester LRCT-C10

  • Measuring Range : 0.10%(m/m) to 30.0%(m/m)
  • Test Samples : 12
  • Coking Oven : Circular heating chamber, 85mm diameter by 105mm deep
  • Test Temperature Range : Ambient to 500°C

Carbon Residue Tester LRCT-B11 FAQ's
  • The Carbon Residue Tester LRCT-B11 is designed with a four-hole heating bath that allows users to test four samples at the same time. This significantly increases lab productivity by reducing the total time spent on individual testing cycles. It is especially useful in high-throughput or quality control environments where multiple samples are analyzed regularly. The uniform heating ensures consistent results across all samples. Additionally, running multiple tests together helps conserve energy compared to separate runs.

  • Labtron’s Carbon Residue Tester LRCT-B11 features a stable electric heating system combined with efficient thermal insulation. This design maintains a consistent internal temperature between test cycles, enabling back-to-back testing. As a result, laboratories can perform consecutive runs with minimal waiting time. It supports continuous workflows in high-demand labs. The system reduces idle time and improves overall testing efficiency.

  • The Carbon Residue Tester LRCT-B11 uses electric heating instead of an open flame, making it cleaner and safer. However, heating petroleum-based samples at high temperatures can still produce vapors or mild fumes depending on the material. It is recommended to place the instrument in a well-ventilated lab or under a fume hood. This ensures a safe and comfortable working environment. Proper ventilation becomes especially important during extended or repeated testing.

  • Our Carbon Residue Tester LRCT-B11 does not require complex preparation before use. Samples should be accurately measured and placed in the provided containers according to ASTM D189 guidelines. It's important to ensure that samples are free from moisture or contaminants. These factors can affect thermal behavior and lead to inconsistent results. Proper preparation helps maintain accuracy and repeatability across tests.

  • The Carbon Residue Tester LRCT-B11 leaves a visible solid residue in the container after testing. This residue is cooled and then weighed to determine the percentage of carbon left from the original sample. The result helps evaluate the deposit-forming tendency of the material. Such data is critical for assessing fuel cleanliness, combustion behavior, and engine compatibility. It supports product approval decisions in fuel and lubricant manufacturing.

  • Labtron’s Carbon Residue Tester LRCT-B11 is built with durable parts and requires minimal maintenance. Users should regularly clean the sample holders and check the heating elements and electrical connections. The digital control panel should also be inspected to ensure proper functionality. Because it has few moving parts, the system is reliable and easy to maintain. It’s ideal for labs seeking consistent performance without frequent servicing.

Post your question?

Our experts are here to help!

Carbon Residue:
Carbon Residue Tester (Ramsbottom) LRCT-B20, Carbon Residue Tester (CONRADSON METHODS) LRCT-B10, Micro Carbon Residue Tester LRCT-C10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608