Request A Quote
Coverslipper LACS-B10

Coverslipper LACS-B10

Coverslipper LACS-B10 offers a throughput capacity of 200 to 400 slides per hour. It features a user-friendly color touch screen interface that displays real-time operational instructions. The coverslipper is compatible with various brands and formats of dyeing racks, including basket and non-basket types. Additionally, it intelligently monitors cover slip quality, automatically discarding broken or defective pieces into a waste cassette. Our coverslipper is designed for use in pathology and histology laboratories to automate the process of placing cover slips.

Request Quote
Specimen Slide Throughput 200 to 400 pieces per hour
Slide Holder Capacity 20 to 30 pieces per holder
Output Magazine Capacity 30 pieces per magazine
Cover Slip Magazine Capacity 120 to160 pieces per magazine
Specimen Slide Size 26 × 75 mm
Cover Slip Size 24 × 50 mm
Device Dimensions 590 × 390 × 620 mm
Packing Dimension 680 × 480 × 820 mm
Net Weight 38 kg
Gross Weight 62 kg
  • Dual slide scanning

  • Quiet exhaust fan with carbon filter

  • Auto blockage detection in slide storage

  • Adjustable glue flow

  • Real time needle detection

  • Bench-top design

Our Coverslipper LACS-B10 is used in pathology and histology laboratories for efficient cover slipping of stained slides. It improves slide preparation speed, consistency, and quality for diagnostic accuracy.

Download catalog for
Coverslipper LACS-B10 Catalog

Models of Coverslippers

Labtron coverslippers can accommodate multiple slides with wide storage capacity. They are equipped with an advanced pressure dispensing system, ensuring faultless results. They feature an intelligent innovative design, eliminating potential disruptions to workflow. Comes with built-in safety features ensuring heightened protection. These coverslippers offer enhanced multiple connectivity options, including USB ports and network interfaces. Our coverslippers ensure peak performance with real-time monitoring and a user-friendly digital interface.

Coverslipper LACS-B11

Coverslipper LACS-B11

  • Speed of Cover-slipping : Max 800 slides/hour
  • Capacity of Slide Rack : 20 slides per rack
  • Cover Program Modes : 6 quick modes selectable by specimen type
  • Storage Capacity : 12 sets of 240 slides
Automatic Cover Slipper LACS-A10

Automatic Cover Slipper LACS-A10

  • Storage Capacity : 6 layers, each layer 20 pieces
  • Slide Size : 26 × 75 mm
  • Number Of Cover Slides Uploaded : ≥ 160
  • Cover Slide Size : 24× (50±10) mm
Coverslipper LACS-C10

Coverslipper LACS-C10

  • Throughput Capacity : 30 slides per minute
  • Slide Seat Capacity : 15 slides
  • Power : Up to 100 W
  • Power Supply : AC 220V ± 10%
Coverslipper LACS-B10 FAQ's
  • Labtron’s Coverslipper LACS-B10 offers a high throughput capacity of 200 to 400 slides per hour, making it a suitable solution for medium to high-volume pathology and histology laboratories. This efficient processing rate helps reduce sample backlog, shortens turnaround time for slide preparation, and ensures laboratories maintain a consistent and dependable workflow for diagnostic and research purposes.

  • Yes, the Coverslipper LACS-B10 is designed for compatibility with both basket and non-basket type dyeing racks used in various staining systems. It intelligently identifies the rack type automatically, eliminating the need for manual input or adjustment and allowing smooth and uninterrupted operation across diverse laboratory setups.

  • The Coverslipper LACS-B10 incorporates a smart monitoring system to inspect each cover slip during the workflow. If a cover slip is found to be broken or defective, the system automatically discards it into a waste cassette. This proactive quality control feature ensures only intact slips are applied, preserving specimen integrity and reducing the chances of errors in the final slide.

  • Yes, the Coverslipper LACS-B10 is equipped with dual slide scanning functionality during the operation cycle. This feature allows the device to verify the placement and condition of each slide twice, significantly reducing the likelihood of missed slides, placement errors, or mechanical failures. It enhances reliability and contributes to higher quality results in slide preparation.

  • Our Coverslipper LACS-B10 features stepless glue flow adjustment, allowing users to fine-tune the flow rate and speed according to the type and viscosity of the sealing glue. It supports both domestically manufactured and imported glues, giving laboratories the flexibility to use different adhesive formulations without compromising performance or slide quality.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.