Differential Scanning Calorimeter LDSC-A12 is a compact and tabletop type fully automatic controlled unit. Features -150 to 550°C of temperature range with 0.1 to 80°C/min of heating rate and 1 to 20°C/min of cooling rate. Designed with metal furnace body and 7-inch touch screen display, has liquid nitrogen refrigeration cooling and 3 sets of thermocouples for efficient operation. Adopted with indirect conduction method for heating and automatic switching of 2-channel atmosphere flow, comes with software control and USB interface for convenient operation and easy data analysis.
Differential Scanning Calorimeter LDSC-A12
Differential Scanning Calorimeter LDSC-A12
Differential Scanning Calorimeter LDSC-A12
Differential Scanning Calorimeter LDSC-A12
Request Quote
Temperature range -150°C to 550°C
Temperature resolution 0.001°C
Temperature fluctuations ± 0.001°C
Temperature repeatability ± 0.1°C
Constant temperature range Program setting ≤ 24 hr
Dynamic heat flow range (DSC range) 0 to ± 600 mW
Heating rate 0.1 to 80°C / min
Cooling rate 1 to 20°C / min (For instant cool only, cannot be Isothermal below RT, and if heating up, the rate can be controlled)
DSC noise 0.01 μW
DSC resolution 0.01 µW
DSC accuracy 0.01 µW
Control Mode Rising temperature, constant temperature (full-automatic)
Curve scanning Rising scan, cooling scan
Gas flow control Embedded digital flow meter and Software control, automatic changing
Atmosphere control gas Nitrogen, Oxygen (auto-switch)
Gas flow-rate 0 to 300 ml/min
Gas pressure 0.2 MPa
Cooling device Liquid nitrogen refrigeration
Thermocouples 3 sets
Parameter standard With standard material, with calibration function, the user may correct temperature and heat enthalpy
Display 7 inches LCD touch screen display
Data interface Standard USB connector
Power supply AC 220 V/50 Hz
Dimension (W×D×H) 680×620×550 mm
Weight 38 kg
  • A compact and tabletop type fully automatic controlled unit
  • -150 to 550°C of temperature range with 0.001°C resolution
  • 0.1 to 80°C/min of heating rate and 1 to 20°C/min of cooling rate
  • Metal furnace body with 7-inch touch screen display
  • Liquid nitrogen refrigeration cooling and 3 sets of thermocouples
  • Indirect conduction method for heating, high stability and uniformity
  • Automatic switching of 2-channel atmosphere flow, short stabilization time
  • Software control and USB interface, easy and convenient data analysis
  • Ideal to determine the inner heat transition relating to temperature and heat flow
Differential Scanning Calorimeter is used for the identification of various physical properties and thermal transitions of polymeric materials across polymer development, performance testing & quality control etc.
Aluminum crucibles × 100 pcs
Ceramic crucibles × 100 pcs
Pure tin grains × 1 bag
Differential Scanning Calorimeter LDSC-A12 Banner
Differential Scanning Calorimeter LDSC-A12 Banner

Models of Differential Scanning Calorimeters

Labtron Differential Scanning Colorimeters measure the properties of samples within a temperature range of -150℃ to 1150℃. Their automated sampling process enhances accuracy in biochemical analysis. They provide real-time monitoring of chemical levels, preventing interruption in testing. Their low reagent consumption reduces overall operating costs significantly. Our Differential Scanning Colorimeters provide a measurement of thermal properties in food technology, pharmaceuticals, and material science.

Differential Scanning Calorimeter LDSC-A11

Differential Scanning Calorimeter LDSC-A11

  • Temperature Range : RT to 600℃
  • Temperature Resolution : 0.001℃
  • Temperature Fluctuations : ±0.01℃
  • Temperature Repeatability : ±0.01℃
Differential Scanning Calorimeter LDSC-A15

Differential Scanning Calorimeter LDSC-A15

  • Temperature Range : RT to 1250℃
  • Heating Rate : 0.1 to 80℃/min
  • Temperature Accuracy : 0.01℃
  • Temperature Resolution : 0.01℃
Differential Scanning Calorimeter LDSC-A10

Differential Scanning Calorimeter LDSC-A10

  • Dynamic Heat Flow Range (DSC Range) : 0 to ± 600mW
  • Temperature Range : RT to 600℃
  • Heating Rate : 0.1 to 100℃/min
  • Temperature Resolution : 0.001℃
Differential Scanning Calorimeter LDSC-A13
Differential Scanning Calorimeter LDSC-A13
  • Temperature Range : Room temperature to 1550 ℃
  • Temperature Resolution : 0.01 ℃
  • Temperature Accuracy : ± 0.1 ℃
  • Temperature Repeatability : ± 0.1 ℃
Differential Scanning Calorimeter LDSC-A14
Differential Scanning Calorimeter LDSC-A14
  • Temperature Range : -40 to 600°C
  • Heating Rate : 0.1 to 100°C/min
  • Temperature Resolution : 0.01°C
  • Temperature Fluctuations : ±0.01°C

Differential Scanning Calorimeter LDSC-A12 FAQ's
  • Labtron’s Differential Scanning Calorimeter LDSC-A12 is designed to handle aqueous electrolyte solutions of varying concentrations—including acidic media (e.g., dilute HCl) and complex solutions like ferricyanide. The system supports small-volume samples, such as those sealed in hermetic aluminum pans or capsules, ensuring secure containment and minimal exposure.

  • Labtron’s Differential Scanning Calorimeter LDSC-A12 is capable of measurements from approximately 0 °C up to +150 °C, enabling studies both near freezing and into elevated temperature regimes where liquid-phase transitions and heat capacity changes are relevant.

  • Yes. The system supports operation under inert gas purging (e.g., nitrogen or argon) to prevent sample oxidation or degradation during heating or analysis—ensuring accurate and stable measurements of sensitive liquid electrolytes.

  • Yes, the Differential Scanning Calorimeter LDSC-A12 offers high sensitivity and precision, ideal for monitoring subtle phase transitions and minor variations in heat capacity (Cp) in liquid samples. Its fine resolution is well-suited for advanced thermal analysis needs.

  • Labtron’s Differential Scanning Calorimeter LDSC-A12 is optimized for small-scale sample volumes, compatible with typical hermetically sealed aluminum capsules or pans. This allows efficient use of precious or limited samples while maintaining analytical accuracy.

Post your question?

Our experts are here to help!

Differential Scanning Calorimeters:
Differential Scanning Calorimeter LDSC-A11, Differential Scanning Calorimeter LDSC-A15, Differential Scanning Calorimeter LDSC-A10, Differential Scanning Calorimeter LDSC-A13, Differential Scanning Calorimeter LDSC-A14, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.