| Temperature Control Range | R.T.+5℃ to 150℃ |
| Temperature Setting Range | 5℃ to 150℃ |
| Time Range | 1min to 99h59m |
| Temperature Stability at 40 to 100℃ | ±0.5℃ |
| Temperature Stability at >100℃ | ±1℃ |
| Block Temperature Uniformity at 40℃ | ±0.3℃ |
| Block Temperature Uniformity at >100℃ | ±0.5℃ |
| Temperature Display Accuracy | 0.1℃ |
| Heating Speed | Less than or equal to 30min (20℃ to 150℃) |
| Sample Capacity | 1 standard block |
| Fuse | 250V,2A/3A,Ф5×20 |
| Power Consumption | 200W |
| Power Supply | AC 220V/AC 110V, 50Hz/60Hz |
| Dimensions (W×D×H) | 200 × 230 × 95 mm |
| Weight | 2.6 kg |
Continuous operation supported
Over-temperature protection device
High temperature control accuracy
Energy-efficient power consumption
Dual voltage power supply
Dry Bath Incubator LDBI-D14 is used for precise sample heating, incubation, and enzymatic reactions. It is widely applied in pharmaceutical, chemical, food safety, clinical, and research laboratories.
| Name | Quantity |
| Block 6 mm × 42 | 1 piece |
| Block 7 mm × 42 | 1 piece |
| Block 10 mm × 20 | 1 piece |
| Block 12 mm × 20 | 1 piece |
| Block 13 mm × 20 | 1 piece |
| Block 15 mm × 12 | 1 piece |
| Block 16 mm × 12 | 1 piece |
| Block 19 mm × 12 | 1 piece |
| Block 20 mm × 6 | 1 piece |
| Block 26 mm × 6 | 1 piece |
| Block 28 mm × 4 | 1 piece |
| Block 40 mm × 2 | 1 piece |
| Block 0.5 ml × 42 | 1 piece |
| Block 1.5 ml × 24 | 1 piece |
| Block 2.0 ml × 24 | 1 piece |
| Block 0.2 ml × 48 | 1 piece |
Download catalog for
Dry Bath Incubator LDBI-D14 Catalog
Available Range :
Dry Bath Incubator LDBI-D11 : R.T.+5℃ to 105℃ Dry Bath Incubator LDBI-D16 : R.T.+5℃ to 120℃ Dry Bath Incubator LDBI-D12 : R.T.+5℃ to 150℃ Dry Bath Incubator LDBI-D10 : RT +5 ℃ to 100 ℃ Dry Bath Incubator LDBI-A32 : RT +5 ℃ to 110 ℃ Dry Bath Incubator LDBI-A22 : RT+5°C to 100°C Dry Bath Incubator LDBI-C10 : RT+5°C to 105°C Dry Bath Incubator LDBI-A12 : RT+5°C to 150°C Dry Bath Incubator LDBI-A14 : RT+5℃ to 150℃ Dry Bath Incubator LDBI-A31 : RT-30°C to 100°C Dry bath incubator LDBI-A30 : RT. (-30) °C - 100°CLabtron Dry-Bath Incubator maintains temperatures ranging from ambient to 160°C, offering contamination-free heating for sample incubation They are equipped with interchangeable blocks to accommodate wide range of tubes and plates. Their construction enhances durability, making them reliable for long-term use. They include integrated timer, allowing automated temperature adjustments without manual intervention. Our Dry-Bath Incubator is ideal for enzyme reactions, incubation and activation of cultures, DNA denaturation, coagulation studies, and sample preparation.








Yes, the Dry Bath Incubator LDBI-D14 can be integrated into semi-automated workflows due to its consistent temperature performance and programmable timer. While it does not feature direct digital or remote control interfaces, it complements robotic arms or lab automation setups where precise thermal preparation is required before automated processing. It’s often used alongside centrifuges, analyzers, or PCR machines for sample preparation. Its simplicity and reliability make it a supportive device in partially automated environments.
Our Dry Bath Incubator LDBI-D14 requires minimal maintenance. Regular cleaning of the block insert area with non-corrosive disinfectants helps maintain hygiene, especially when working with biological samples. Blocks should be removed and wiped down to avoid buildup. Air vents should be kept dust-free for proper ventilation. It's recommended to inspect the power cord and fuse periodically. Calibration should be verified annually if used in regulated environments. Proper care ensures extended lifespan and optimal performance.
Weighing only 2.6 kg with compact dimensions (200 × 230 × 95 mm), the Dry Bath Incubator LDBI-D14 is highly portable. It's ideal for mobile labs, shared lab spaces, or applications that require transportation between departments. Its lightweight design and durable body make it easy to carry without compromising stability. Dual voltage support (AC 110V/220V) further enhances flexibility in different locations. This makes it a practical choice for on-site testing or educational institutions
Labtron’s Dry Bath Incubator LDBI-D14 is suitable for operation in temperature-controlled environments such as cold rooms, provided that the ambient temperature remains within the unit’s specified operating range. Its dry heating mechanism eliminates concerns related to condensation, which are common with traditional water baths. For best results, the incubator should be used in laboratory conditions that fall within standard ambient temperature ranges. In colder settings, the device may require additional warm-up time to reach and maintain precise temperature levels. It is important to maintain unobstructed airflow around the unit to ensure consistent performance and prevent overheating of internal components.
Designed to support a wide range of laboratory protocols, the Dry Bath Incubator LDBI-D14 allows manual stepwise programming by setting specific time and temperature intervals for each stage of an experiment. Although it does not feature automated multi-step ramping, temperature adjustments can be made manually during operation without interrupting the process. This flexibility is particularly advantageous for workflows that involve multiple thermal phases, such as pre-incubation, enzymatic reactions, and nucleic acid denaturation. With its rapid heating capability reaching 150? from 20? in 30 minutes or less, the unit minimizes downtime between steps. This makes it especially suitable for laboratories conducting sequential heat-based treatments or multi-stage thermal protocols where precise and timely transitions are essential.
Our Dry Bath Incubator LDBI-D14 is well-suited for handling a wide range of sensitive biological and chemical samples, thanks to its precisely controlled and stable dry heat environment. This makes it particularly advantageous for applications that require gentle and consistent thermal conditions, such as DNA hybridization, enzyme inactivation, protein denaturation, and other temperature-critical molecular biology protocols. Its dry heating design eliminates the need for water, significantly reducing the risk of contamination, spills, or microbial growth commonly associated with traditional water baths. However, it is important to note that the unit is not intended for use with volatile solvents, flammable substances, or hazardous chemicals unless they are securely contained and compliant with laboratory safety standards. To ensure optimal safety and performance, samples should always be placed in high-quality, lab-grade tubes with secure sealing caps to prevent evaporation, pressure buildup, or accidental leakage during prolonged heating. This attention to containment not only protects sample integrity but also contributes to a safer working environment for laboratory personnel.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608