Gas Chromatography Mass Spectrometry LGCS-A10

Gas Chromatography Mass Spectrometry LGCS-A10

Gas Chromatography Mass Spectrometry LGCS-A10 operates with a mass range of 15 to 550 amu, ensuring precise analysis. It features a portable design, weighing under 19 kg, allowing easy on-site use. The intelligent wizard-operated software system and multiple injection modes, including sorbent tube and MS direct injection, provide versatility for varied analytical needs. Its waterproof, dustproof, and earthquake-resistant design ensures reliable performance. Our LGCS-A10 is ideal for rapid qualitative and quantitative analysis of organic compounds.

Gas Chromatography Mass Spectrometry GC-MS-A10
Gas Chromatography Mass Spectrometry GC-MS-A10
Request Quote
Mass Range 15 to 550 amu
Resolution >1 amu
Injection Modes Single MS, sorbent tube, quantitative ring injection
Sensitivity Single MS: Toluene (5 mg/m³) S/N ≥ 10
Sorbent Tube: Toluene (10 ppb) S/N ≥ 50
Split Inlet: Octa fluor naphthalene (100 pg/µL) S/N ≥ 15
Scanning Modes Full Scan, SIM, and MS/MS
Response Time ≤ 30s for 1 ppm Toluene
Recovery Time ≤ 30s for 1 ppm Toluene to minimize sample impact
Dynamic Range 10⁷
Ion Source EI source with 70 eV ionization energy
Detector Electron multiplier tube
Quality Analyzer Ion trap mass analyzer
Anti-Vibration Grade Yes
Waterproof Grade Yes
Vacuum ≤ 3000 µTorr
Automatic Tuning Auto-calibration on the main units mass axis
Calibration Function Real-time internal standard calibration
Pre-Sampling Function Prevents dead volume impact on analysis
Blowback Function Clears residue from sorbent tubes post-analysis
Carrier Gas Built-in helium gas bottle
Sampling Flow Electronically controlled and adjustable
Environmental Temperature -5℃ to 45℃
Storage Temperature -20℃ to 70℃
Relative Humidity 0% to 95% RH
Ambient Pressure Usable at 54 to 101.3 kPa, suitable for highlands
Positioning System GPS and BeiDou dual-mode, real-time tracking
Communication Mode LAN and Wi-Fi enabled
Database NIST Standard Spectrum Library, AMDIS, NIOSH Database, Environmental Standards Reference Database
Data Acquisition Built-in IPC with touch screen human-machine interaction
Data Processing Built-in IPC (touch screen), External PC (keyboard and mouse interaction)
Power Consumption 140
Power Supply 220VAC ±10% / 50 Hz
Dimension  221 × 429 × 440 mm
Packaging Dimension 600 × 600 × 350 mm
Net Weight  19 kg
Gross Weight 21 kg
  • Whole heat tracing technology
  • Built-in battery and carrier gas
  • Rapid VOC/SVOC analysis
  • Fast MS direct injection response
  • Parallel sorbent tube/loop design
  • Trolley with shock-absorbing module
  • Vehicle-ready with quick warm-up
  • Multiple injection modes: sorbent tube, MS injection, headspace, and SPME

Gas Chromatography Mass Spectrometry LGCS-A10 is widely used for precise analysis of volatile and semi-volatile organic compounds in fields like environmental monitoring, forensic investigations, pharmaceutical research, and industrial quality control.

Built-in adsorption thermal desorption module host1 Set
Sampling probe1 Set
Single-shoulder strap1 Set
External tuning standard sample1 Set
Host storage case1 Set
He gas (10pcs/box)1 box
Tedlar gas bag (1L)5 Pieces
Gas bottle anti-falling rack1 Set
SPME handle1 Piece
20mL clear glass sample bottle7 Pieces
SPME fiber PDMS/DVB coating (3sticks/box)1 box
Host installation acceptance package1 Set
Engineering pre-installed accessories1 Set
SPME injection kit storage case1 Set
0.5μL micro syringe1 Piece
1.0mL gas-tight syringe1 Piece
Syringe injection kit storage case1 Set
SPME comprehensive pre-treatment instrument1 Piece
SPME comprehensive pre-treatment instrument consumables package1 Piece
Headspace injection system1 Piece
Headspace installation acceptance package1 Piece
40 mL clear glass sample vial100 Pieces
Portable GC-MS dynamic dilution instrument1 Piece
Portable GC-MS dynamic dilution instrument engineering package1 Piece
Air bag negative pressure sampling kit1 Piece
PTFE hydrophobic filter membrane50 Pieces
Portable GCMS special car1 Piece
Vehicle-mounted shock absorption platform1 Piece
Mobile power1 Piece

Models of Gas Chromatography Mass Spectrometry (GC-MS)

Labtron gas chromatography mass spectrometry (GC-MS) systems are combining both gas chromatography and mass spectrometry capabilities. They have electron multipliers and pre-filter mass analyzers for accurate analysis. These systems maintain an interface temperature and make use of seven-stage temperature programming. These column flow rates increase productivity and allow for the simultaneous examination of several components. They incorporate mass analyzers, turbo molecular pump vacuum systems, and electronic flow control systems for stability and reliability. Our systems provide screening and quantification in a single analytical run by integrating mass spectrometers, gas chromatographs, and auto samplers.

Gas Chromatography Mass Spectrometry LGCS-A11

Gas Chromatography Mass Spectrometry LGCS-A11

  • Gas Chromatography Flow Rate : 1 to 1.5 ml / min
  • Maximum Flow Rate : 10 ml / min
  • Inlet Temperature : 450 °C
  • Pressure Range : 0 to 50 psi

Gas Chromatography Mass Spectrometry (GC-MS):
Gas Chromatography Mass Spectrometry LGCS-A11, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.