Request A Quote
Hematology Analyzer LHTA-A10

Hematology Analyzer LHTA-A10

Hematology Analyzer LHTA-A10 offers reports 25 clinical parameters with 3 histograms and 3D scattergram, and 4 additional research parameters. With a throughput of 60 tests per hour and minimal sample volume requirements, it enhances laboratory productivity. Its performance ensures excellent linearity, low carry-over, and superior precision for WBC, RBC, HGB, and PLT measurements. It is equipped with multiple connectivity options, integrating seamlessly into modern laboratory workflows. This analyzer operates efficiently under standard laboratory environmental conditions.

Hematology Analyzer LHTA-A10
Request Quote
Measuring principle Tri-angle laser scatter
Flow cytometry method
Impedance method for RBC and PLT counting
Cyanide-free method for HGB test
3D Scattergram analysis
Parameters 25 Reportable parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#
1 3D Scattergram 3 Histograms (WBC/BASO, RBC, PLT)
4 Research parameter: ALY%, ALY#, IG%, IG#
Test Mode CBC mode, CBC+DIFF mode
Venous whole blood, Capillary whole blood and Prediluted
Throughput 60 tests/hour
Sample volumes CBC+DIFF mode: ≤ 20 μl
CBC mode: ≤ 10 μl
Display 14-inch touch screen
Resolution 1366 × 768
Storage 100,000 sample results (including histograms, scattergrams and patient information)
WBC Performance Linearity range: 0 to 300 × 109/L
Carry Over: ≤ 0.5%
CV: ≤ 2.0 %
RBC Performance Linearity range: 0 to 8 ×1012/L
Carry Over: ≤ 0.5%
CV: ≤ 1.5 %
HGB Performance Linearity range: 0 to 250 g/L
Carry Over: ≤ 0.5%
CV: ≤ 1.5 %
PLT Performance Linearity range: 0 to 3000 × 109/L
Carry Over: ≤ 1.0%
CV: ≤ 4.0 %
Interface 4 USB ports, 1 LAN port
Printout Support various external USB printers, printout formats user definable
Communication Bi-direction LIS, support HL7 protocol Internal RFID reader
Working Temperature 10 to 30 ℃
Working Humidity 20% to 85%
Working Air Pressure 70 to 106 kPa
Working Latitude ≤ 3500 m
Power Supply AC 100 to 240 V, 50/60 Hz
Dimension (L × W × H) 480 × 375 × 517mm
Net Weight 36 kg
Gross Weight 53 kg
  • Multiple Test Modes
  • High Stability & Accuracy
  • User-Friendly System
  • Large Touch Screen Display
  • External USB Printer Support
  • Wide Connectivity Options
  • Safe Cyanide-Free HGB Testing
  • Compact And Space-Saving Design
  • Low Sample Volume Requirement
  • High Throughput Performance
  • Reliable Data Storage

Our Hematology Analyzer LHTA-A10 is widely used in clinical laboratories, hospitals, diagnostic centers, and research institutions for routine blood analysis and differential counts.

Accessories NameQuantity
Power cable1 pc
Grounding wire1 pc
Fuse (10A)2 pcs
Waste bottle lid assembly1 pc
Diluent bottle lid assembly1 pc
P Tube200 cm
PU Tube50 cm
X Tube60 cm
Y Tube9 cm
CZ Tube2 Sets
XZ Tube2 Sets
E Tube50 cm
Plastic Screw4 pcs
Hematology Analyzer LHTA-A10 | Display : 14 inch touch screen | Storage : 100,000 sample results
Hematology Analyzer LHTA-A10 | Automatic hematology analyzer | 3D holographic scattergram


Models of Hematology Analyzer

Labtron Hematology analyzers are capable of assessing a wide range of blood parameters, including RBC count, WBC count, platelet count, hemoglobin concentration, and more. These analyzers can process a large number of blood samples quickly and accurately, with their automation capability. Our hematology analyzer utilizes both the impedance method and a Cyanide-free technique for cell counting and hemoglobin measurement. They offer triple counting modes, including venous, capillary, and prediluted options. These analyzers adapt to diverse sample types and enhance flexibility in diagnostic procedures.

Hematology Analyzer LHTA-B10

Hematology Analyzer LHTA-B10

  • Throughput : 60 samples/hour
  • Channels : 2
  • Histograms : 3 histograms (including WBC, RBC, PLT histograms)
  • Sample Volume : Whole blood: 12 µl Pre-diluted: 20 µl
Hematology Analyzer LHTA-A11

Hematology Analyzer LHTA-A11

  • Automation : Semi-automatic
  • Measuring Principle : Electrical impedance, SFT method for Hemoglobin
  • Sample Volume : Venous whole blood: 9.6μL
  • Throughput : 60 tests/Hour (open sampling)
Hematology Analyzer LHTA-C10

Hematology Analyzer LHTA-C10

  • Throughput : Whole blood: Up to 60 samples per hour Pre-diluent: Up to 60 samples per hour
  • Sample Capacity : Whole blood: 20 µL Pre-diluent: 20 µL
  • Parameters : WBC, LYM%, MON%, NEU%, EOS%, BAS%, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW_CV, RDW_SD, PLT, MPV, PDW, PCT, P_LCR, P_LCC, RETIC%, RETIC_ABS, IRF, ALY%, ALY%, LIC%, LIC%, NRBC%, NRBC%
  • Histograms : 2 for RBC and PLT

Hematology Analyzer:
Hematology Analyzer LHTA-B10, Hematology Analyzer LHTA-A11, Hematology Analyzer LHTA-C10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 20 8004 3587

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.