Request A Quote
Ion Chromatography System LICS-A23

Ion Chromatography System LICS-A23

Ion chromatography system LICS-A23 features a high-pressure, low-pulse pump that delivers stable flow, with a flow rate of 0.001 to 12 mL/min and a maximum pressure of 42 MPa. Our ion chromatography system features built-in 3D circulating constant temperature technology for uniform and stable temperature control. Used to detect small anions and cations in food, chemical, mining, metallurgy, and environmental fields.

Ion chromatography system LICS-A23 ( front view)
Ion chromatography system LICS-A23 ( view from side )
Request Quote
Pump Type High-pressure, low-pulse, two-piston tandem advection pump
Maximum Pump Pressure 42 MPa
Flow Rate Range 0.001 to 12 mL/min
Pressure Ripple ≤ 0.5%
Flow Stability ≤ 0.1%
Tube External Diameter 1/16
Valve Rotor Material PEEK
Valve Medium Contact Material PEEK
Column Heater Operating Temperature Range Ambient +5 to 60 °C
Column Heater Temperature Accuracy ±0.1 °C
Column Heater Temperature Stability ≤0.1 °C/h
Supported Column Sizes 2, 3, 4, and 5mm I.D.; Max length 250 mm + 50 mm guard column
Suppressor Type Self-regenerating electrolytic micro-membrane suppressor
Suppressor Maximum Pressure 6.0 MPa
Non-Suppressed Chromatography Supported
Void Volume <40 μL (4 mm); <15 μL (2 mm)
Flow Path PEEK material; chemically inert, metal-free; supports pH 0 to 14 and reversed-phase solvents
Sensor Leakage sensor
Indicator Lamp Operation and error indication (Standard configuration)
Peristaltic Pump 1-unit, automatic post flushing
Gas-Liquid Separator 1 unit (Standard configuration)
Conductivity Detector Type Auto-range conductivity detector
Conductivity Detector Cell Volume ≤0.4 μL
Conductivity Detector Detection Range 0 to 50,000 μS/cm
Conductivity Detector Resolution ≤0.0020 nS/cm
Output Voltage -6000 to +6000 mV (adjustable)
Electronic Noise 0.02 nS
Baseline Noise ≤0.0003 μS/cm
Baseline Drift ≤0.001 μS
Temperature Range Ambient +5 °C to 60 °C
Temperature Accuracy ±0.01 °C
Temperature Compensation 1.7%/°C
Maximum System Pressure 8 MPa
Instrument Linearity ≥0.999
Quantitative Repeatability ≤0.25%
Qualitative Repeatability ≤0.1%
Minimum Detectable Concentration Cl⁻ ≤0.0001 μg/mL; Li⁺ ≤0.0001 μg/mL
Degassing Not included (Optional)
Power Consumption 150 W
Power Supply AC 110 to 240V, 50Hz/60Hz
Dimension 310 × 400 × 530 mm
Packaging Dimension Box 1 560 × 490 × 330 mm
Packaging Dimension Box 2 400 × 500 × 730 mm
Weight 22 Kg
Gross Weight Box 1 15 Kg
Gross Weight Box 2 30 Kg
  • Built in peristaltic pump

  • intelligent workstation

  • Gas-liquid separator

  • Leakage sensor

Ion Chromatography System LICS-A23 is used to detect small molecules like anions and cations in fields such as food, chemicals, mining, metallurgy, and environmental testing.

Accessories Name 

Quantity

Ion chromatograph host

1 pc

High-pressure double plunger advection pump

1 pc

Conductivity detector

1 pc

Manual 6-way valve

1 pc

Anion column

1 pc

Anion guard column

1 pc

Anion suppressor

1 pc

Chromatography software

1 pc

Column heater

1 pc

Spare parts kits

1 pc

Vacuum degassing pump

1 pc

Sand core filtration device

1 pc

0.22 µm syringe filter

100 pcs

Cation column

1 pc

Cation guard column

1 pc

Cation suppressor

1 pc

Autosampler

1 pc

Ion Chromatography System LICS-A23 | Pressure Ripple: ≤ 0.5% | Flow Stability: ≤ 0.1%
Ion Chromatography System LICS-A23 | Gas-liquid separator| Leakage sensor

Models of Ion Chromatography System

Labtron ion chromatography systems ensure excellent system stability and performance with capabilities for both anion and cation detection. They feature advanced conductivity detectors, auto-samplers, and intelligent workstations for stability and high accuracy. These systems include built-in eluent management, automatic cleaning modes and real time monitoring. Our ion chromatography systems have user-friendly interfaces and advanced technologies, ensuring reliability.

Ion Chromatography System LICS-A24

Ion Chromatography System LICS-A24

  • Maximum pressure : 42 MPa / 6000 Psi
  • Flow range : 0.001 to 10.000 mL/min
  • Flow accuracy : ≤0.1%
  • Flow repeatability : RSD ≤0.01%
Ion chromatograph system LICS-A20

Ion chromatograph system LICS-A20

  • Generator Eluent Types : KOH/NaOH/LiOH/MSA
  • Eluent Concentration Range : 0.1 to 100mM
  • Eluent Concentration Increment : 0.1mM
  • Eluent Flow Rate : 0.1 to 5.0mL/min
Ion chromatograph system LICS-A22

Ion chromatograph system LICS-A22

  • Ion Chromatographic pump : TypeHigh pressure and low pulse double plunger tandem advection pumpMaximum pressure35 MPa (PEEK)Display pressure accuracy≤ 0.1 MPaFlow stability(0.2 to 0.5) ml/ min ≤ 3 % , (0.5 to 1.0) ml/ min ≤ 2 %, > 1.0 ml/ min ≤ 2 %Flow range0.001 to 9.999 ml/ minPressure pulse≤ 0.5 %
  • Numerical control and electromagnetic injection : Maximum pressure35 MPaContact material of the rotorPEEKControl modeBy Stepper motorPower supplyDC 24 V
  • Column heater : Operating temperature rangeRoom temperature 20 to 60°C ( 68 to 140°F)Controlling temperature accuracy± 0.01°CAllowable deviation of column heater temperature± 2°CTemperature stability≤ 1°C/ h
  • Flow system : Plastic flow pathMade up of PEEK materialSix way valvePEEK material pressure 5000 psi, independent automatic collection and flow function
Ion chromatograph system LICS-A21
Ion chromatograph system LICS-A21
  • Ion Chromatographic Pump : TypeHigh pressure and low pulse double plunger tandem advection pumpMaximum pressure35 MPa (PEEK)Pressure display accuracy≤ 0.1 MPaFlow stability(0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 %Flow range0.001 to 9.999 ml/ minPressure pulse≤ 0.5%
  • Conductivity detector : TypeTemperature Control and Bipolar Conductivity DetectorDetection modeBipolar conductivity detectionCell volume≤ 0.8 µLDetection range0 to 45000 µS/ cmDetection resolution≤ 0.0020 nS/ cmOutput voltage- 6000 to +6000 mV (adjustable)Baseline noise≤ 0.05 % F.S.Baseline drift≤ 3 % FS/ 30 minOperating temperature rangeRoom temperature +5 to 60°C (41 to 140°F)Controlling temperature accuracy± 0.01°CMaximum pressure10 MPaLinear range≥ 103Instruments linearity≥ 0.999Quantitative repeatability≤ 1.0 %Qualitative repeatability≤ 1.0 %Minimum detectable concentrationCl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml
  • Flow system : Plastic flow pathMade of PEEK materialsSix way ValvePEEK material, 5000 psi pressure, independent automatic collection and flow function
  • Power supply : 150 W
Ion Chromatography System LICS-A23 FAQ's
  • The Labtron Ion Chromatography System LICS-A23 is designed for detecting and analyzing small ions such as anions (like chloride or nitrate) and cations (like lithium or calcium). It is commonly used in various industries including food safety, chemical production, mining, metallurgy, and environmental monitoring. For example, it can be used to check the purity of water, monitor pollutants in the environment, or test for harmful ions in food and beverage products. Its high sensitivity allows it to detect even very low concentrations of these ions, making it ideal for both routine and research applications.

  • Labtron’s LICS-A23 comes equipped with a high-pressure, low-pulse tandem pump that ensures a steady and accurate flow of liquids during analysis, with a flow rate range of 0.001 to 12 mL/min and a maximum pressure of 42 MPa. It also features built-in 3D circulating constant temperature control, which helps maintain uniform temperature throughout the system. This ensures precise and stable results, especially when testing sensitive ions. The conductivity detector has a high resolution of ?0.0020 nS/cm, and its auto-range function makes it suitable for both high and low concentration samples. Additionally, a leakage sensor, gas-liquid separator, and automatic post-flushing peristaltic pump help improve safety and reduce contamination risk.

  • Labtron’s LICS-A23 is capable of analyzing both anions and cations using its dual-column configuration. It includes separate anion and cation columns, guard columns, and suppressors, which are all provided as standard accessories. The suppressor system is a self-regenerating electrolytic micro-membrane type that enhances signal clarity by removing background noise. This system can be used for non-suppressed chromatography as well, depending on the testing requirements. For ease of use, the system also comes with chromatography software, a column heater, and an autosampler, allowing users to process multiple samples automatically.

  • The Labtron LICS-A23 is highly sensitive and capable of detecting extremely low concentrations of ions. It can detect chloride (Cl?) and lithium (Li?) ions at concentrations as low as 0.0001 ?g/mL. This high level of sensitivity is achieved through its advanced conductivity detector, stable flow system, and precise temperature control with accuracy as fine as ±0.01°C. The void volume of the system is also minimized (<40 ?L for 4 mm columns), ensuring sharp and accurate peak resolution. Its instrument linearity (?0.999) and repeatability (quantitative ?0.25%) further confirm its reliability in research and quality control laboratories.

  • To operate the Labtron LICS-A23 smoothly, you will need a Windows 10 or Windows 11 (64-bit) computer with at least an Intel Core i5 processor, 8 GB RAM, and 500 GB storage. The system connects to the PC using intelligent chromatography software, which is included in the standard package. This software controls the entire system, from sample injection to data analysis, and supports real-time monitoring, report generation, and peak integration. The device is powered by a standard AC supply (110 to 240V, 50/60Hz) and consumes 150 W of power, making it energy-efficient for regular lab use.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.