| Generator Eluent Types | KOH/NaOH/LiOH/MSA |
| Eluent Concentration Range | 0.1 to 100mM |
| Eluent Concentration Increment | 0.1mM |
| Eluent Flow Rate | 0.1 to 5.0mL/min |
| Maximum Pressure | 30MPa |
| Minimum Pressure | 5MPa |
| Accuracy Of Gradient | 0.0015 |
| Vacuum Degasser Degree | -70kPa |
| Degasser Internal Volume | 300μL |
| Degasser Maximum Flow Rate | 10mL/min |
| Degassing Efficiency | 1.0mL/min 90% |
| Degassing Volume | 7.5mL |
| Alarm system | Pressure Alarm, Liquid Leakage Alarm, and Washing Liquid Alarm |
| Flow Path | Chemically inert, metal-free PEEK flow paths |
| Pump Type | High-pressure and low-pulse two-piston tandem advection pump |
| Pump Maximum Pressure | 42MPa |
| Pump Flow Rate | 0.001 to 9.999mL/min |
| Pump Pressure Ripple | ≤ 0.5% |
| Pump Flow Precision | ≤ 0.1% |
| Pump Flow Accuracy | ≤ 0.1% |
| External Diameter of The Tube | 1/16 |
| Valve Control Mode | Stepper Motor |
| Valve Power Supply | 24V (DC) |
| Column Heater Temperature Range | Ambient + 5 to 60 ℃ |
| Column Heater Temperature Accuracy | ±0.1℃ |
| Temperature Stability | ≤ 0.05℃/h |
| Columns Supported | 2, 3, 4, and 5 mm I.D. |
| Analytical Column Size | 250 mm |
| Guard Column Size | 50 mm |
| Conductivity Detector Type | Auto-range conductivity |
| Conductivity Detector Cell Volume | ≤ 0.8μL |
| Conductivity Detection Range | 0 to 50000μS/cm |
| Conductivity Detector Resolution | ≤ 0.0020nS/cm |
| Detector Output Voltage | -6000 to +6000mv(adjustable) |
| Detector Electronic Noise | 0.02nS |
| Detector Baseline Noise | ≤ 0.0002μS/cm |
| Detector Baseline Drift | ≤ 0.001μS |
| Detector Temperature Range | Ambient +5℃ to 60℃ |
| Detector Temperature Accuracy | ±0.01℃ |
| Detector Temperature Compensation | 1.7 %/℃ |
| Detector Maximum Pressure | 10.0MPa |
| Detector Instrument Linearity | ≥ 0.999 |
| Detector Quantitative Repeatability | ≤ 0.2% |
| Detector Qualitative Repeatability | ≤ 0.5% |
| Minimum Detectability Concentration | Clˉ ≤ 0.0001ug/mL Li⁺ ≤ 0.0001ug/mL |
| Suppressor Type | Self-Regeneration electrolytic micro-membrane suppressor |
| Suppressor Maximum Pressure | 6.0MPa |
| Non-Suppressed Chromatography | Yes/support |
| Suppressor Void Volume | <40μL (4mm) <15μL (2mm) |
| Suppressor Power Supply | 150W |
| External Dimension (W × L × H) | 360 × 500 × 560 mm |
| Net Weight | 26 Kg |
| Gross Weight | 32 Kg |
Our ion chromatograph system can be used to detect fluoride and chloride in coal tar, ammonium in photoresists, bromate and bromide in drinking water, anions in engine coolants, lithium battery electrolytes, etc.
| Accessories | Quantity |
| Ion chromatograph host | 1 |
| High-pressure double plunger advection pump | 1 |
| Conductivity detector | 1 |
| Anion column | 1 |
| Anion guard column | 1 |
| Anion suppressor | 1 |
| Cation column | 1 |
| Cation guard column | 1 |
| Cation suppressor | 1 |
| Chromatography software | 1 |
| Column heater | 1 |
| PEEK flow path | 1 |
| Online gas-liquid separator | 1 |
| Spare parts kits | 1 |
| Vacuum degassing pump | 1 |
| Sand core filtration device | 1 |
| 0.22um syringe filter | 100 |
| Built-in anion eluent generator | 1 |
| Autosampler | 1 |
| Leakage Sensor | 1 |
| Gas-liquid separator | 1 |
Download catalog for
Ion chromatograph system LICS-A20 Catalog
Download manual for
Ion chromatograph system LICS-A20 Manual
Labtron ion chromatography systems ensure excellent system stability and performance with capabilities for both anion and cation detection. They feature advanced conductivity detectors, auto-samplers, and intelligent workstations for stability and high accuracy. These systems include built-in eluent management, automatic cleaning modes and real time monitoring. Our ion chromatography systems have user-friendly interfaces and advanced technologies, ensuring reliability.




Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608