Pour and Cloud Point Tester LLTT-A14

Pour and Cloud Point Tester LLTT-A14

Pour and Cloud Point Tester LLTT-A14 is a concise designed unit, made as per ASTM D97,ASTM D2500, ASTM D5853 Standard Test Method for Pour Point of Petroleum Oils and ASTM D5773, Standard Test Method of Cloud Point of Petroleum Products. Features two cooling bath chambers with temperature controller, ensures fast and high cooling efficiency. Equipped with new type of refrigeration compressor, the temperature of both cooling bath is same with ±1°C precision. With benchtop structure and easy usage, this pour and cloud point tester is suitable to determine pour point and cloud point of petroleum oils.

Request Quote
Chamber quantity 2 chambers
Chamber temperature control RT to -70 ℃
Temperature control accuracy ±0.5℃
Ambient temperature ≤30℃
Refrigeration system R13 R502
Power Consumption 800 W
Power supply AC 220 V± 10%, 50 Hz
Product Dimension (L×W×H) 610 × 510 × 690 mm
Packaging Dimension (L×W×H) 650 × 550 × 730 mm
Net Weight 55 Kg
Gross Weight 68 Kg
  • Concise designed unit with benchtop structure
  • Made as per ASTM D97,ASTM D2500, ASTM D5853 Standard Test Method for Pour Point of Petroleum Oils
  • Designed as per ASTM D5773, Standard Test Method of Cloud Point of Petroleum Products
  • Two cooling bath chambers with temperature controller and new type of refrigeration compressor
  • Both cooling bath temperature is same with ±1°C precision
  • Suitable to determine pour point and cloud point of petroleum oils
  • Fast and high cooling efficiency with easy usage

Pour and cloud point tester is used for precise and convenient flow testing of petroleum products, biodiesel fuels, additives and lubricating oils etc.

Thermometer (-38° to 50°C) scale division 1°C × 1 pc
Thermometer (-80° to 20°C) scale division 1°C × 1 pc
Pour point tube plugs × 4 pcs
Pour point tubes × 4 pcs
Bath cover × 4 pcs
Washers (Ф35 × 3.1 o-ring) ; Pour point tube positioning ring × 4 pcs
Felt gasket round dish × 4 pcs
15 A fuse (Ф5×20) × 2 pcs
Fixed mount × 1 pc
Stop collar for thermometer × 2 pcs

Models of Low Temperature Tester

Labtron Low Temperature Tester assess performance and durability of materials under extremely low temperature. They utilize cryogenic fluids for achieving extremely cold conditions effectively and efficiently. Their built-in vacuum systems minimize heat transfer, enhancing testing accuracy at sub-zero situation. They are equipped with sensors to monitor and record thermal changes, enabling detailed analysis. Our Low Temperature Tester evaluate samples in aerospace, automotive, electronics, pharmaceuticals, research and development, and food industries.

Cloud and Pour Point Tester LLTT-A17

Cloud and Pour Point Tester LLTT-A17

  • Sample Volume : 4.5 ml
  • Sample Test Interval : 1°C
  • Temperature range : 51°C to -70°C
  • Repeatability : ±1°C
Automatic Pour Point Tester LLTT-A23

Automatic Pour Point Tester LLTT-A23

  • Ambient temperature : ≤ 30 ℃
  • Refrigeration speed : > 40 °C / 10 min
  • Repeatability for solidifying point : ≤ 2 °C
  • Repeatability for pour point : ≤ 3 °C
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • Ambient Temperature : (-10) ℃ to 35 ℃
  • Relative Humidity : ≤ 85 %
  • Sample Cup Inner Diameter : 31.0 to 32.0 mm
  • Sample Cup Wall Thickness : 1.0 to 1.5 mm
Multifunctional Low Temperature Tester LLTT-A16
Multifunctional Low Temperature Tester LLTT-A16
  • Refrigeration system : New-type refrigeration compressor
  • Controlling temperature of cold trough : Cold trough I: 0 °C, ± 0.5 °C;Cold trough II: 0 °C, (-17) °C, ± 0.5 °C;Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C;Cold trough IV: (-70) °C, ± 0.5 °C
  • Ambient temperature : ≤ 30 ℃
  • Relative humidity : ≤ 85 %
Automated Cold Filter Plugging Point Tester LLTT-A18
Automated Cold Filter Plugging Point Tester LLTT-A18
  • Temperature Range of Measuring Chamber : RT to -67°C
  • Temperature Accuracy : ± 0.1°C
  • Measuring Range : RT to -51°C
  • Measuring Accuracy : ± 0.1°C
Pour and Cloud Point Tester LLTT-A14 FAQ's
  • The Pour and Cloud Point Tester LLTT-A14 is suitable for testing high-viscosity oils such as heavy fuel oils or lubricants. These types of samples may require preheating before testing and slower cooling rates for accurate results. Interpreting the pour point can be difficult when the sample becomes very thick, so users should observe carefully and follow ASTM guidelines closely. The instrument’s wide temperature range and controlled cooling support accurate testing for such complex samples.

  • Labtron’s Pour and Cloud Point Tester LLTT-A14 may show errors if the sample is contaminated, not cooled consistently, or if the user misjudges cloud formation. These errors can lead to inconsistent or incorrect results. To avoid this, operators should always use clean, dry glassware, ensure sample volume is consistent, and control the cooling environment. Following ASTM standards and conducting repeat tests can help confirm accurate readings and identify any discrepancies.

  • The Pour and Cloud Point Tester LLTT-A14 may show unclear results for some blended or treated fuels. If there is no visible cloud or flow stoppage, check if the cooling rate is steady and if the thermometer is correctly calibrated. Make sure the sample is clean and properly mixed. You may need to cool it further or let it sit at a stable temperature longer before checking again. If unclear, run a second test and compare with ASTM example images for guidance.

  • The Pour and Cloud Point Tester LLTT-A14 should be turned off immediately if a test tube breaks inside the chamber. Allow the chamber to return to room temperature before removing broken glass or spilled sample. Use gloves and safe tools to avoid cuts or contamination. Clean the chamber using a soft cloth and a solvent recommended in the user manual. Do not use metal tools, as they may damage the chamber lining. Once fully cleaned and dried, restart the unit and check that it reaches the correct test temperature before resuming work.

  • Labtron’s Pour and Cloud Point Tester LLTT-A14 should be used according to ASTM protocols to avoid incorrect results. The samples must be clean, well-mixed, and free from water or dust particles, as these can affect cloud or pour behavior. During the cooling process, it is important to keep the setup free from external vibrations or air movements that may disturb wax crystal formation. The test jar must be properly sealed, and temperature readings must be taken consistently. Operators should wear protective gloves and eyewear, as the low temperatures and sample handling involve safety risks.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.