Request A Quote
Octane Analyzer LOCT-D10

Octane Analyzer LOCT-D10

Octane Analyzer LOCT-D10 measures fuel resistance to knocking, with range of 40 to 120 octane number. Feature high accuracy sensor for consistent and dependable evaluation results. Automatic barometric pressure compensation optimizes results for varying environmental conditions. Its four parallel carburetor bowls ensure balanced testing across multiple configurations. Equipped with refrigerated vertical jet system to improve temperature management during testing.

Request Quote
Working Range 40 to 120 Octane Number
Cast Iron Cylinder Bore (Diameter) 82.55mm (3.250 inch)
Piston Stroke 114.30mm (4.50 inch)
Cylinder Displacement 0.61L (37.33 in³)
Compression Ratio Range Adjustable 4:1 to 18:1, automatically or manually controlled
Engine Speed 900rpm ± 9rpm for Motor Method
600rpm ± 6rpm for Research Method
Clearance for Both Intake and Exhaust Valves (Engine running and hot) 0.20mm ± 0.025mm (0.008 in ± 0.001 in)
Spark Plug Gap 0.51mm ± 0.13mm (0.020 in ± 0.005 in)
Lubricating Oil Pressure 172 to 207 kPa (25 psi to 30 psi)
Lubricating Oil Temperature 57°C ± 8°C (135°F ± 15°F)
Cylinder Jacket Coolant Temperature 100°C ± 1.5°C (212°F ± 3°F)
Intake Mixture Temperature (Motor Method) 149°C ± 1°C (300°F ± 2°F)
Intake Air Temperature (Motor Method) 38°C ± 2.8°C (100°F ± 5°F)
Intake Air Temperature (Research Method) 52°C ± 1°C (125°F ± 2°F) for operation at standard barometric pressure, maintained within ±1°C (±2°F) for other prevailing barometric pressure conditions
Ignition Timing (Real-time Displayed) For Motor Method: 26° BTDC (ε=5.0), adjusted automatically by the computer as CR changed
For Research Method: Constant 13° BTDC
I/O Port USB
Test Methods ASTM D2699, ASTM D2700, IP 236, IP 237, EN ISO 5163, EN ISO 5164, GB/T 5487, GB/T 503
Data Export LIMS or Printer
Machine Power 12KW
Operating Conditions 5 to 35°C
20 to 90% RH, Non-condensing
Power Supply AC380V ± 10%, 50/60Hz
AC110V ± 10%, 50/60Hz
Dimensions (W×D×H) 1650 × 820 × 1480mm
Packaging Dimension 1900 × 1100 × 1650 mm
Net Weight 900 Kg
Gross Weight 1250 kg
  • Standardized single cylinder engine
  • Variable compression ratio feature
  • Signal sensors for monitoring
  • Automatic time recording capability
  • Upper exhaust cooled circulator

Our Octane Analyzer LOCT-D10 is versatile for are fuel quality testing in refineries, automotive research, and regulatory compliance. They optimize engine performance, develop new fuels, and ensure adherence to industry standards.

Download catalog for
Octane Analyzer LOCT-D10 Catalog

Models of Octane & Cetane Analyzer

Labtron Octane & Cetane Analyzer is specialized to measure performance of gasoline combustion and ignition quality of diesel fuel. They feature user-friendly interface for easy navigation and operation. Their calibration standards are traceable to national and international reference materials. They are equipped with graphical display for visualization of data and trends. Our Octane & Cetane Analyzer is versatile for refineries, fuel testing labs, and quality control facilities.

Octane & Cetane Analyzer LOCT-B10

Octane & Cetane Analyzer LOCT-B10

  • Octane number range : 40 to 125 ON
  • Maximum error limit octane number : ±0.5 ON
  • Maximum parallel ON difference : ±0.2
  • Antiknock range : 0.5 to 15 %
Octane & Cetane Analyzer LOCT-A10

Octane & Cetane Analyzer LOCT-A10

  • Test Liquids : Diesel, Gasoline
  • Measuring Range for Gasoline : Aviation gasoline: 86.0 to 105.0/MONAutomobile gasoline: 50.0 to 115.0/RON
  • Measuring Range for Diesel : Automobile diesel oil: 25 to 75/CN
  • Measuring Accuracy : Aviation gasoline: ≤ ± 1.5/MONAutomobile gasoline: ≤ ± 1.5/RON, ≤ ± 1.5/MONAutomobile diesel oil: ≤ ± 2.5/CN, ≤ ± 2.5/CIRetest of regression samples: ≤ ± 0.5/RON, ≤ ± 0.5/MONTest of regression sample: ≤ ± 1.5/RON, ≤ ± 1.5/MONCalibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON
Cetane Analyzer LCA-A10

Cetane Analyzer LCA-A10

  • Cetane Number Range : 0 to 100 (Typical testing CN range: 30 to 65)
  • Cast Iron Cylinder Bore (Diameter) : 82.55mm (3.250 inch)
  • Piston Stroke : 114.30mm (4.50 inch)
  • Compression Ratio Range : Adjustable 8:1 to 36:1 by external handwheel assembly
Octane & Cetane Analyzer LOCT-A20
Octane & Cetane Analyzer LOCT-A20
  • Measurement Items : Motor Gasoline & Diesel Fuel
  • Octane Number (ON) Range : 40 to 120
  • Octane Permissible Error : ± 0.5 max
  • Cetane Number (CN) Range : 20 to 100

Octane & Cetane Analyzer:
Octane & Cetane Analyzer LOCT-B10, Octane & Cetane Analyzer LOCT-A10, Cetane Analyzer LCA-A10, Octane & Cetane Analyzer LOCT-A20, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.