Request A Quote
Pen-type PH Meter LPHM-B10

Pen-type PH Meter LPHM-B10

Pen-type pH Meter LPHM-B10 offers pH measuring range of 1.00 to 15.00 for accurate pH measurements in both acidic and alkaline solutions. It features a resolution of 0.01pH, enabling precise detection of pH variations. The device is integrated with temperature measurement mode for monitoring sample temperature. Our pen-type pH meter includes automatic calibration option for reliable pH measurements without manual adjustments.

Pen-type pH Meter LPHM-B10_Top View
Pen-type pH Meter LPHM-B10_Top View
Request Quote
pH Measuring Range 1.00 to 15.00 pH
pH Resolution 0.01pH
pH Accuracy ± 0.01 pH
Stability ± 0.01 Ph / 3h
Temp. compensation range 0 to 60°C
Show Temperature Yes
Auto Calibration 1 to 3 point (pH 4.00 / 7.00 / 10.01)
Power Supply Lithium Batteries (CR2032) × 2
Product Dimension 148 × 29 × 14 mm
Weight 43 g
  • Dual Display Mode

  • Automatic Power Off

  • Multiple Calibration Points

  • Electrode Invalidation Display

  • Wide pH Measurement Range

Pen-type pH Meter LPHM-B10 is a handheld device designed to measure the acidity or alkalinity (pH) of liquids. It is widely used in aquaculture, agriculture and hydroponics for maintaining optimal pH levels.

Models of Pen-type pH Meter

Labtron offers a diverse range of Pen-type pH Meters designed to measure hydrogen ion concentration in various samples. It features a portable, lightweight design for easy handling across multiple applications. The pH Meter with its digital display provides clear and convenient readings. Its waterproof construction and replaceable electrodes enhance the durability and lifespan of the pH Meter. Our pH Meter is widely utilized in water testing, educational laboratories, research facilities, and industrial quality control settings.

Pen-type PH Meter LPHM-A11

Pen-type PH Meter LPHM-A11

  • pH Measuring range : -1.00 to 15.00 pH
  • pH Resolution : 0.01 pH
  • pH Accuracy : ± 0.05 pH
  • Temperature Range : 0 to 60℃
Pen-type PH Meter LPHM-A10

Pen-type PH Meter LPHM-A10

  • pH Measuring range : -1.00 to 15.00 pH
  • pH Resolution : 0.1 pH
  • pH Accuracy : ± 0.2 pH
  • Temperature Range : 0 to 60℃
Pen-type PH Meter LPHM-B11

Pen-type PH Meter LPHM-B11

  • pH Measuring Range : 0 to14.0 pH
  • pH Resolution : 0.1pH
  • pH Accuracy : ± 0.1 pH
  • Stability : ± 0.1 pH / 3h
Pen-type PH Meter LPHM-B10 FAQ's
  • Labtron supplies advanced models of pen-type pH meters. Calibration ensures the accuracy of pH readings by aligning the meter's readings with known standards. Typically, calibration is performed using pH buffers like 4.00, 7.00, and 10.00. Regular calibration compensates for electrode drift over time. Some meters offer automatic calibration, simplifying the process. Neglecting calibration can lead to erroneous readings. It's recommended to calibrate the meter before each use. Proper calibration extends the lifespan of the meter. It also ensures consistent and reliable measurements.

  • Labtron supplies premium models of pen-type pH meter . Electrode maintenance is crucial for accurate measurements. After use, rinse the electrode with distilled water to remove contaminants. For proteinaceous deposits, soak the electrode in a dilute acid solution. Avoid touching the glass bulb to prevent damage. Store the electrode in a storage solution or as recommended by the manufacturer. Regular maintenance prolongs the electrode's life and ensures reliable readings. Always refer to the user manual for specific care instructions. Proper storage prevents the electrode from drying out, which can lead to inaccurate readings.

  • Labtron’s Pen-type pH Meter has advanced features. Several factors can influence pH readings. Electrode condition and cleanliness are paramount; fouled electrodes yield inaccurate results. Temperature fluctuations can alter pH values, making ATC essential. Improper calibration leads to erroneous readings. Using expired or incorrect buffer solutions can skew results. Electromagnetic interference from nearby equipment may affect measurements. Ensure the meter is suitable for the specific application to minimize errors. Regular maintenance and calibration are vital for consistent accuracy. Environmental factors like humidity can also impact performance.

  • Labtron supplies advanced pH Meter. Pen-type pH meters are versatile but have limitations. They are suitable for aqueous solutions and some non-aqueous liquids. Highly viscous, oily, or protein-rich solutions can clog the electrode. Strong acids or bases may damage the electrode over time. Always check the manufacturer's specifications for compatibility. For specialized liquids, consider using meters designed for those specific conditions. Proper electrode maintenance is crucial when testing diverse samples. Some models offer replaceable electrodes for easier maintenance.

  • Labtron’s supplies advanced pH Meter. The IP (Ingress Protection) rating indicates the level of protection against dust and water. A higher IP rating means better resistance to environmental factors. For instance, an IP65 rating ensures the meter is dust-tight and protected against water jets. This is crucial for fieldwork in various weather conditions. Meters with higher IP ratings are more durable and reliable in challenging environments. Always choose a meter with an appropriate IP rating for your specific application. It ensures longevity and consistent performance. Higher IP ratings may also allow for easier cleaning and maintenance.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.